Dynamic simulation of variable capacity refrigeration systems under abnormal conditions

There are often abnormal working conditions at evaporator outlet of a refrigeration system, such as two-phase state in transient process, and it is essential to investigate such transient behaviours for system design and control strategy. In this paper, a dynamic lumped parameter model is developed to simulate the transient behaviours of refrigeration system with variable capacity in both normal and abnormal working conditions. The appropriate discriminant method is adopted to switch the normal and abnormal conditions smoothly and to eliminate the simulated data oscillation. In order to verify the dynamic model, we built a test system with variable frequency compressor, water-cooling condenser, evaporator and electronic expansion valve. Calculated values from the mathematical model show reasonable agreement with the experimental data. The simulation results show that the transient behaviours of the variable capacity refrigeration system in the abnormal working conditions can be calculated reliably with the dynamic model when the compressor rotary speed or the opening of electronic expansion valve changes abruptly.

[1]  Ricardo Nicolau Nassar Koury,et al.  Numerical simulation of a variable speed refrigeration system , 2001 .

[2]  Liang Chen,et al.  A new model of mass flow characteristics in electronic expansion valves considering metastability , 2009 .

[3]  Hubertus Tummescheit,et al.  Moving Boundary Models for Dynamic Simulations of Two-Phase Flows , 2002 .

[4]  Guoliang Ding,et al.  Recent developments in simulation techniques for vapour-compression refrigeration systems , 2007 .

[5]  S. Klein,et al.  NIST Standard Reference Database 23: NIST Thermodynamic and Transport Properties of Refrigerants and Refrigerant Mixtures-REFPROP, Version 6.0 | NIST , 1998 .

[6]  Morten Willatzen,et al.  A general dynamic simulation model for evaporators and condensers in refrigeration. Part II: simulation and control of an evaporator , 1998 .

[7]  Guoliang Ding,et al.  Dynamic simulation of natural convection bypass two-circuit cycle refrigerator–freezer and its application: Part I: Component models , 2004 .

[8]  Guoliang Ding,et al.  Simulation of a geothermal heat pump with non-azeotropic mixture , 2003 .

[9]  Xiang-Dong He,et al.  Dynamic modeling and multivariable control of vapor compression cycles in air conditioning systems , 1996 .

[10]  Shiming Deng,et al.  A study on the operational stability of a refrigeration system having a variable speed compressor , 2008 .

[11]  Changqing Tian,et al.  Instability of automotive air conditioning system with a variable displacement compressor. Part 1. Experimental investigation , 2005 .

[12]  Morten Willatzen,et al.  A general dynamic simulation model for evaporators and condensers in refrigeration. Part I: moving-boundary formulation of two-phase flows with heat exchange , 1998 .

[13]  Andrew G. Alleyne,et al.  APPLICATION OF MULTIVARIABLE ADAPTIVE CONTROL TO AUTOMOTIVE AIR CONDITIONING SYSTEMS , 2003 .

[14]  H. Harry Asada,et al.  Multivariable control of vapor compression systems , 1998 .

[15]  Eric W. Grald,et al.  A moving-boundary formulation for modeling time-dependent two-phase flows , 1992 .