Feasibility of continuous long-term glucose monitoring from a subcutaneous glucose sensor in humans.

The feasibility of continuous long-term glucose monitoring in humans has not yet been demonstrated. Enzyme-based electrochemical glucose sensors with telemetric output were subcutaneously implanted and evaluated in five human subjects with type I diabetes. Subject-worn radio-receiver data-loggers stored sensor outputs. Every 1-4 weeks the subject's glucose levels were manipulated through the full clinical range of interest using standard protocols. Reference blood glucose samples were obtained every 5-10 min and analyzed in our hospital clinical laboratory and/or on glucose meters. The sensor data were evaluated versus the reference data by linear least squares regression and by the Clarke Error Grid method. After surgical explantation and device inspection, the tissue-sensor interface was evaluated histologically. The remaining sensor-membranes were also recalibrated for comparison with preimplant performance. Four of the five glucose sensors tracked glucose in vivo. One sensor responded to manipulated glucose changes for 6.2 months with clinically useful performance (>/=90% of sensor glucose values within the A and B regions of the Clarke Error Grid). For this sensor, recalibration was required every 1-4 weeks. The other three transiently responding sensors had electronic problems associated with packaging failure. The remaining sensor never tracked glucose because of failure to form any sustained connection to adjacent subcutaneous tissue. Thus, stable, clinically useful sensor performance was demonstrated in one of five subjects with diabetes for a sustained interval of greater than 6 months. While this glucose sensor implant technology shows promise in humans, it needs to be made more reliable and robust with respect to device packaging and sensor-tissue connection.

[1]  Francis Moussy,et al.  Strategies for testing long-term transcutaneous amperometric glucose sensors. , 2005, Diabetes technology & therapeutics.

[2]  Megan C Frost,et al.  Implantable chemical sensors for real-time clinical monitoring: progress and challenges. , 2002, Current opinion in chemical biology.

[3]  M. Shults,et al.  A subcutaneous glucose sensor with improved longevity, dynamic range, and stability of calibration. , 2000, Diabetes care.

[4]  Peter G. Jacobs,et al.  DESIGN OF A LOW POWER PORTABLE RF RECEIVER / DATALOGGER SYSTEM FOR ACQUIRING DATA FROM A FULLY IMPLANTABLE GLUCOSE SENSOR IN HUMANS , 1999 .

[5]  R. Holman,et al.  Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). UK Prospective Diabetes Study (UKPDS) Group. , 1998 .

[6]  J. Jansen,et al.  Performance of subcutaneously implanted glucose sensors: a review. , 1998, Journal of investigative surgery : the official journal of the Academy of Surgical Research.

[7]  M. Shults,et al.  A telemetry-instrumentation system for monitoring multiple subcutaneously implanted glucose sensors , 1994, IEEE Transactions on Biomedical Engineering.

[8]  M. Shults,et al.  Evaluation of a Subcutaneous Glucose Sensor out to 3 Months in a Dog Model , 1994, Diabetes Care.

[9]  M. Shults,et al.  Prediction of pocket-portable and implantable glucose enzyme electrode performance from combined species permeability and digital stimulation analysis. , 1994, Analytical chemistry.

[10]  M. Shults,et al.  Enzymatic Glucose Sensors: Improved Long-Term Performance In Vitro and In Vivo , 1994, ASAIO journal.

[11]  K. Stokes Polyether Polyurethanes: Biostable or Not? , 1988, Journal of biomaterials applications.

[12]  D. Cox,et al.  Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood Glucose , 1987, Diabetes Care.

[13]  G. Hicks,et al.  The Enzyme Electrode , 1967, Nature.