Study of the stability and uncertainty of an external cavity diode laser through a Michelson wavemeter

A Michelson wavemeter was developed to test the accuracy and give traceability to the wavelength of external cavity diode lasers. These lasers were stabilized using a Littrow configuration and an iodine gas cell as frequency reference, and they will be used as light sources in the assembly of a new interferometric system for gauge block calibration. Previously, the uncertainty evaluation of the Michelson wavemeter with a Vernier counter had to be made, in which, as it is usual, the counting set starts and stops when the interference phases of the reference and unknown wavefronts coincide.

[1]  J. Rutman Characterization of phase and frequency instabilities in precision frequency sources: Fifteen years of progress , 1978, Proceedings of the IEEE.

[2]  D. W. Allan,et al.  Time and Frequency (Time-Domain) Characterization, Estimation, and Prediction of Precision Clocks and Oscillators , 1987, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  B. Stoicheff,et al.  Vernier fringe‐counting device for laser wavelength measurements , 1983 .

[4]  F. Zernike,et al.  Accurate laser wavelength measurement with a precision two-beam scanning Michelson interferometer. , 1981, Applied optics.

[5]  Frank V. Kowalski,et al.  Digital wavemeter of cw lasers , 1976 .

[6]  S. A. Lee,et al.  Interferometric real‐time display of cw dye laser wavelength with sub‐Doppler accuracy , 1976 .

[7]  P. Ciddor Refractive index of air: new equations for the visible and near infrared. , 1996, Applied optics.

[8]  M. Braun,et al.  A high precision compact Michelson-Sagnac wavemeter , 1987 .

[9]  T J Quinn,et al.  Practical realization of the definition of the metre, including recommended radiations of other optical frequency standards (2001) , 2003 .

[10]  J. Vigué,et al.  A systematic error of Michelson's type lambdameters , 1986 .

[11]  Fred L. Walls,et al.  Draft revision of IEEE STD 1139-1988 standard definitions of physical quantities for fundamental frequency and time metrology — random instabilities , 1999 .

[12]  Wolfgang Demtröder,et al.  The accuracy of laser wavelength meters , 1985 .

[13]  D. W. Allan,et al.  Statistics of atomic frequency standards , 1966 .

[14]  E. Iso,et al.  Measurement Uncertainty and Probability: Guide to the Expression of Uncertainty in Measurement , 1995 .

[15]  P. J. Fox,et al.  A reliable, compact, and low-cost Michelson wavemeter for laser wavelength measurement , 1999 .

[16]  L. Chassagne,et al.  Highly accurate laser wavelength meter based on Doppler effect , 2006 .

[17]  K. Tanaka,et al.  Accurate wavelength meter for cw lasers. , 1986, Applied optics.

[18]  M. Amer,et al.  Calibration of a Michelson-type laser wavemeter and evaluation of its accuracy , 2010 .

[19]  Benito V. Dorrío,et al.  Design of an interferometric system for gauge block calibration , 2013 .

[20]  Robert E. Scholten,et al.  Frequency noise characterisation of narrow linewidth diode lasers , 2002 .