Accuracy Comparison of Implant Impression Techniques: A Systematic Review.

BACKGROUND Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. PURPOSE The aim of this study was to identify the most accurate impression technique and factors affecting the impression accuracy. MATERIAL AND METHODS A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit. A total of 417 articles were identified; 32 were selected for review. RESULTS All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique, and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in nine; six studies tested vinyl polysiloxane and one study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intraoral optical devices were compared in four studies. CONCLUSIONS The most accurate results were achieved with two configurations: (1) the optical intraoral system with powder and (2) the open technique with splinted squared transfer copings, using polyether as impression material.

[1]  W. Psoter,et al.  Analysis of three-dimensional distortion of two impression materials in the transfer of dental implants. , 2010, The Journal of prosthetic dentistry.

[2]  W M Al-Omari,et al.  The dimensional accuracy of four impression techniques with the use of addition silicone impression materials. , 2007, The Journal of clinical dentistry.

[3]  Charles J Goodacre,et al.  Clinical complications in fixed prosthodontics. , 2003, The Journal of prosthetic dentistry.

[4]  H. G. Filho,et al.  Accuracy of impression techniques for implants. Part 2 - comparison of splinting techniques. , 2009, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[5]  G Burawi,et al.  A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system. , 1997, The Journal of prosthetic dentistry.

[6]  Torsten Jemt,et al.  The precision of fit of milled titanium implant frameworks (I-Bridge) in the edentulous jaw. , 2008, Clinical implant dentistry and related research.

[7]  S. Hovijitra,et al.  A comparative study of the accuracy between plastic and metal impression transfer copings for implant restorations. , 2013, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[8]  H. G. Filho,et al.  Evaluation of Transfer Impressions for Osseointegrated Implants at Various Angulations , 2004, Implant dentistry.

[9]  M. Miranda,et al.  Evaluation of the accuracy of different transfer impression techniques for multiple implants. , 2011, Brazilian oral research.

[10]  J I Nicholls,et al.  Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials. , 1993, The International journal of prosthodontics.

[12]  Neil L. Starr,et al.  Clinical Methods for Evaluating Implant Framework Fit , 1999 .

[13]  H. Weber,et al.  Effect of splinted and nonsplinted impression techniques on the accuracy of fit of fixed implant prostheses in edentulous patients: a comparative study. , 2011, The International journal of oral & maxillofacial implants.

[14]  Yijin Ren,et al.  Application of Intra-Oral Dental Scanners in the Digital Workflow of Implantology , 2012, PloS one.

[15]  K. Akca,et al.  Accuracy of 2 impression techniques for ITI implants. , 2004, The International journal of oral & maxillofacial implants.

[16]  P. Vigolo,et al.  An evaluation of impression techniques for multiple internal connection implant prostheses. , 2004, The Journal of prosthetic dentistry.

[17]  C. Ercoli,et al.  The accuracy of implant impressions: a systematic review. , 2008, The Journal of prosthetic dentistry.

[18]  Marco Del Corso,et al.  Optical three-dimensional scanning acquisition of the position of osseointegrated implants: an in vitro study to determine method accuracy and operational feasibility. , 2009, Clinical implant dentistry and related research.

[19]  M. Compagnoni,et al.  The effect of splint material rigidity in implant impression techniques. , 2010, The International journal of oral & maxillofacial implants.

[21]  D Assif,et al.  Accuracy of implant impression techniques. , 1996, The International journal of oral & maxillofacial implants.

[22]  M. Çehreli,et al.  The influence of functional forces on the biomechanics of implant-supported prostheses--a review. , 2002, Journal of dentistry.

[23]  Daniel Edelhoff,et al.  Digital evaluation of the reproducibility of implant scanbody fit—an in vitro study , 2011, Clinical Oral Investigations.

[24]  E. D. de Avila,et al.  Effect of splinting in accuracy of two implant impression techniques. , 2014, The Journal of oral implantology.

[25]  J. Güth,et al.  Clinical study evaluating the discrepancy of two different impression techniques of four implants in an edentulous jaw , 2013, Clinical Oral Investigations.

[26]  M. Balkenhol,et al.  Influence of impression technique and material on the accuracy of multiple implant impressions. , 2008, The International journal of prosthodontics.

[27]  Chang-Whe Kim,et al.  Accuracy of a proposed implant impression technique using abutments and metal framework , 2010, The journal of advanced prosthodontics.

[28]  Sang-Jik Lee,et al.  Accuracy of five implant impression technique: effect of splinting materials and methods , 2011, The journal of advanced prosthodontics.

[29]  W. Mörmann The evolution of the CEREC system. , 2006, Journal of the American Dental Association.

[30]  A B Carr,et al.  Comparison of impression techniques for a five-implant mandibular model. , 1992, The International journal of oral & maxillofacial implants.

[31]  H. Weber,et al.  Clinical accuracy outcomes of closed-tray and open-tray implant impression techniques for partially edentulous patients. , 2011, The International journal of prosthodontics.

[32]  E. D. de Avila,et al.  Comparison of the accuracy of plastic and metal stock trays for implant impressions. , 2012, The International Journal of Oral and Maxillofacial Implants.

[33]  Mohammad Javad Kharazifard,et al.  Accuracy of implant impressions with different impression coping types and shapes. , 2012, Clinical implant dentistry and related research.

[34]  Edwin A McGlumphy,et al.  Comparison of the accuracy of Biomet 3i Encode Robocast Technology and conventional implant impression techniques. , 2013, The International journal of oral & maxillofacial implants.

[35]  Werner H. Moörmann The evolution of the CEREC system , 2006 .

[36]  Wirley Gonçalves Assunção,et al.  Evaluation of Impression Accuracy for Implant at Various Angulations , 2010, Implant dentistry.

[37]  Anders Ortorp,et al.  The accuracy of an implant impression technique using digitally coded healing abutments. , 2012, Clinical implant dentistry and related research.

[38]  S E Eckert,et al.  Analysis of incidence and associated factors with fractured implants: a retrospective study. , 2000, The International journal of oral & maxillofacial implants.

[39]  Hakimeh Siadat,et al.  Three-dimensional accuracy of implant and abutment level impression techniques: effect on marginal discrepancy. , 2011, The Journal of oral implantology.

[40]  B. Şermet,et al.  A comparative analysis of the accuracy of different direct impression techniques for multiple implants. , 2012, Australian dental journal.

[41]  German O Gallucci,et al.  Accuracy of implant casts generated with splinted and non-splinted impression techniques for edentulous patients: an optical scanning study. , 2012, Clinical oral implants research.

[42]  M. Çehreli,et al.  The Significance Of Passive Framework Fit In Implant Prosthodontics: Current Status , 2001, Implant dentistry.

[43]  L. Leu,et al.  Effects of prosthesis materials and prosthesis splinting on peri-implant bone stress around implants in poor-quality bone: a numeric analysis. , 2002, The International journal of oral & maxillofacial implants.

[44]  Roberto Sorrentino,et al.  Effect of implant angulation, connection length, and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study. , 2009, Clinical implant dentistry and related research.

[45]  J. Güth,et al.  Evaluation of impression accuracy for a four-implant mandibular model—a digital approach , 2011, Clinical Oral Investigations.

[46]  Shinji Ono,et al.  Optical impression method to measure three-dimensional position and orientation of dental implants using an optical tracker. , 2013, Clinical oral implants research.

[47]  Seung-Geun Ahn,et al.  Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study , 2010, The journal of advanced prosthodontics.