Surface functionalization of a microfluidic biosensor for bacteria detection and identification

Rapid identification and detection of bacteria is an important issue in environmental and food science. We have developed an impedance-based method to simultaneously identify and detect bacteria in a derivatized microfluidic chamber with monoclonal antibodies. The presence of bacteria in the solution can be selectively recognized and fixed on the chamber wall and detected via impedance change in real time. The optimum reaction time between antibody and bacteria has been estimated using a simple model and evaluated experimentally. Various concentrations of cultured E. coli cells ranging from 105 to 108 CFU/ml were tested using the biosensor. By taking the advantage of a microfluidic system, the bacteria can be concentrated and accumulated on the chamber wall by continuously perfusing the chamber with bacterial suspension, therefore, enhancing the detection limit of the sensor. Using this approach, the biosensor was able to detect 106 CFU/ml E. coli (BL21(DE3)) via five consecutive perfusions. The selectivity of the sensor is demonstrated by testing the antibody reaction for two bacteria stains, E. coli and M. catarrhalis. By derivatizing the chamber walls with specific antibodies, we can clearly identify the bacteria that are specific to the antibodies in the detection chamber. The simplicity of the technique also makes the device portable and ideal for clinical and field applications.

[1]  F. Ligler,et al.  Detection of multiple toxic agents using a planar array immunosensor. , 1998, Biosensors & bioelectronics.

[2]  Norman Epstein,et al.  Elements of particle deposition onto nonporous solid surfaces parallel to suspension flows , 1997 .

[3]  S Koch,et al.  Optical flow-cell multichannel immunosensor for the detection of biological warfare agents. , 2000, Biosensors & bioelectronics.

[4]  P Silley,et al.  Impedance microbiology--a rapid change for microbiologists. , 1996, The Journal of applied bacteriology.

[5]  D. Lauffenburger,et al.  A dynamical model for receptor-mediated cell adhesion to surfaces. , 1987, Biophysical journal.

[6]  R. Bashir,et al.  Impedance microbiology-on-a-chip: microfluidic bioprocessor for rapid detection of bacterial metabolism , 2005, Journal of Microelectromechanical Systems.

[7]  Nicolò Dossi,et al.  A piezoelectric immunosensor based on antibody entrapment within a non-totally rigid polymeric film , 2005 .

[8]  E. Alocilja,et al.  Design and fabrication of a microimpedance biosensor for bacterial detection , 2004, IEEE Sensors Journal.

[9]  A. Bhunia,et al.  Microscale electronic detection of bacterial metabolism , 2002 .

[10]  Frederick Sachs,et al.  Volume cytometry: microfluidic sensor for high-throughput screening in real time. , 2005, Analytical chemistry.

[11]  Evangelyn C. Alocilja,et al.  Fabrication of a disposable biosensor for Escherichia Coli O157:H7 detection , 2003 .

[12]  Guo-Li Shen,et al.  Simultaneous immunoassay using piezoelectric immunosensor array and robust method , 1996 .

[13]  M. Avena,et al.  A simple model for adsorption kinetics at charged solid–liquid interfaces , 2001 .

[14]  F Ying-Sing,et al.  Piezoelectric crystal for sensing bacteria by immobilizing antibodies on divinylsulphone activated poly-m-aminophenol film. , 2000, Talanta.

[15]  Frederick Sachs,et al.  Microfluidic actuation using electrochemically generated bubbles. , 2002, Analytical chemistry.