Outdoor test cells for building envelope experimental characterisation – A literature review

In the past decades the construction sector experienced the diffusion of a wide variety of complex building envelope components and passive elements and strategies, characterized by a dynamic response to the climatic parameters. Many of these components have been claimed to contribute to reducing building energy use and improving occupants׳ comfort. These kind of envelope elements need nevertheless to be tested under laboratory and real dynamic weather conditions in order to characterise, and possibly to model, their behaviour and their effectiveness both in terms of energy saving and indoor environmental quality. Both indoor laboratories and outdoor test cells have been developed in order to tackle the challenging issue of experimentally characterising innovative envelope elements. However, not always the experimental methodologies are fully and explicitly described in the available literature, and they are rarely compared to other types of experimental procedures. The aim of the present paper is to describe and review recent state of the art technologies for outdoor test cells. The paper starts with a short introduction on potentialities and limitations of outdoor facilities with respect to indoor laboratories and real buildings field tests, and it continues with a detailed classification and description of the most relevant outdoor test cells developed in recent years.

[1]  Lorenzo Pagliano,et al.  Achieving the Net Zero Energy Target in Northern Italy: Lessons Learned from an Existing Passivhaus with Earth-to-Air Heat Exchanger , 2013 .

[2]  A. Schaelin,et al.  Airflow patterns and thermal behavior of mechanically ventilated glass double façades , 2004 .

[3]  Aris Tsangrassoulis,et al.  Comparing the energy performance of an electrochromic window under various control strategies , 2007 .

[4]  Staf Roels,et al.  Experimental analysis of cavity ventilation behind rainscreen cladding systems: A comparison of four measuring techniques , 2015 .

[5]  R. Judkoff,et al.  International Energy Agency Building Energy Simulation Test and Diagnostic Method for Heating, Ventilating, and Air-Conditioning Equipment Models (HVAC BESTEST); Volume 1: Cases E100-E200 , 2002 .

[6]  Staf Roels,et al.  Moisture response of building facades to wind-driven rain: Field measurements compared with numerical simulations , 2009 .

[7]  F. Kuznik,et al.  Experimental study of a mechanically ventilated double-skin façade with venetian sun-shading device: A full-scale investigation in controlled environment , 2010 .

[8]  Paul Strachan Simulation support for performance assessment of building components , 2008 .

[9]  H. Madsenb,et al.  Modelling the heat dynamics of a monitored Test Reference Environment for Building Integrated Photovoltaic systems using stochastic differential equations , 2012 .

[10]  Luisa F. Cabeza,et al.  Life cycle assessment of the inclusion of phase change materials (PCM) in experimental buildings , 2010 .

[11]  Jonathan D. Cryer,et al.  Time Series Analysis , 1986 .

[12]  M. Mcevoy,et al.  Investigations into the functioning of a supply air window in relation to solar energy as determined by experiment and simulation , 2006 .

[13]  Arnold Janssens,et al.  Experimental investigation of the impact of room/system design on mixed convection heat transfer , 2012 .

[14]  Hans Simmler,et al.  Experimental and numerical determination of the total solar energy transmittance of glazing with venetian blind shading , 2008 .

[15]  Gregory M. Maxwell,et al.  Empirical validations of solar gain models for a glazing unit with exterior and interior blind assemblies , 2008 .

[16]  Søren Østergaard Jensen,et al.  Validation of building energy simulation programs: a methodology , 1995 .

[17]  Luisa F. Cabeza,et al.  Thermal analysis of a ventilated facade with PCM for cooling applications , 2013 .

[18]  Arnold Janssens,et al.  Full scale test facilities for evaluation of energy and hygrothermal performances , 2011 .

[19]  Gregory M. Maxwell,et al.  An empirical validation of modelling solar gain through a glazing unit with external and internal shading screens , 2007 .

[20]  Constantinos A. Balaras,et al.  Development of a neural network heating controller for solar buildings , 2000, Neural Networks.

[21]  Harry Boyer,et al.  A thermal model for phase change materials in a building roof for a tropical and humid climate: Model description and elements of validation , 2014 .

[22]  R. Judkoff,et al.  Applying the building energy simulation test (BESTEST) diagnostic method to verification of space conditioning equipment models used in whole-building energy simulation programs , 2002 .

[23]  Paul Strachan,et al.  Series of experiments for empirical validation of solar gain modeling in building energy simulation codes—Experimental setup, test cell characterization, specifications and uncertainty analysis , 2006 .

[24]  Francesco Causone,et al.  A Zero Energy Concept Building for the Mediterranean Climate , 2014 .

[25]  Rainer Pfluger,et al.  Improvements on PASSYS test cells , 1996 .

[26]  Carsten Rode,et al.  Integrated calculation of hygrothermal conditions of buildings , 2002 .

[27]  Christophe Menezo,et al.  Experimental study of a chimney enhanced heat emitter designed for internal renovation of buildings , 2012 .

[28]  Fernanda Rodrigues,et al.  Performance of a window shutter with phase change material under summer Mediterranean climate conditions , 2015 .

[29]  J. H Klems Net energy performance measurements on electrochromic skylights , 2001 .

[30]  Per Heiselberg,et al.  Empirical Validation of Building Simulation Software: Modelling of Double Facades , 2007 .

[31]  Tomas Gil-Lopez,et al.  Influence of double glazing with a circulating water chamber on the thermal energy savings in buildings , 2013 .

[32]  Gregory M. Maxwell,et al.  An empirical validation of the daylighting algorithms and associated interactions in building energy simulation programs using various shading devices and windows , 2007 .

[33]  P. Wouters,et al.  The PASSYS Test Cells: A Unique European Network of High Quality Outdoor Test Facilities for Thermal Building Research , 1990 .

[34]  S. Corgnati,et al.  Experimental assessment of the performance of an active transparent façade during actual operating conditions , 2007 .

[35]  P. H. Baker,et al.  Test cell evaluation of supply air windows to characterise their optimum performance and its verification by the use of modelling techniques , 2003 .

[36]  James D. Hamilton Time Series Analysis , 1994 .

[37]  H. Boyer,et al.  Empirical validation of the thermal model of a passive solar cell test , 2001 .

[38]  A.H.C. van Paassen,et al.  Symbiosis of the double skin facade with the HVAC system , 2005 .

[39]  Tadiwos Zerihun Desta,et al.  Experimental data set for validation of heat, air and moisture transport models of building envelope , 2011 .

[40]  Mattheos Santamouris,et al.  On the combination of air velocity and flow measurements in single sided natural ventilation configurations , 1996 .

[41]  Per Heiselberg,et al.  Comparative Test Case Specification – Test Cases DSF100_2 and DSF400_3: Report for IEA ECBCS Annex 43/SHC Task 34 Validation of Building Energy Simulation Tools , 2005 .

[42]  R. Judkoff,et al.  ETNA BESTEST Empirical Validation Data Set , 2005 .

[43]  M Janak,et al.  Assessing the overall performance of advanced glazing systems , 1998 .

[44]  P. Baker,et al.  Test cell analysis of the use of a supply air window as a passive solar component , 2000 .

[45]  Hongxing Yang,et al.  Performance of ventilated double-sided PV façade compared with conventional clear glass façade , 2013 .

[46]  Henrik Madsen,et al.  Models for describing the thermal characteristics of building components , 2008 .

[47]  Luisa F. Cabeza,et al.  Life Cycle Assessment of experimental cubicles including PCM manufactured from natural resources (esters): A theoretical study , 2013 .

[48]  Dirk Saelens,et al.  Reliable building energy performance characterisation based on full scale dynamic measurements , 2016 .

[49]  Nuno M. Mateus,et al.  Validation of EnergyPlus thermal simulation of a double skin naturally and mechanically ventilated test cell , 2014 .

[50]  P. Nektarios,et al.  Dynamic U-value estimation and energy simulation for green roofs , 2012 .

[51]  Antonio Piccolo,et al.  Thermal performance of an electrochromic smart window tested in an environmental test cell , 2010 .

[52]  Luisa F. Cabeza,et al.  Experimental study on the performance of insulation materials in Mediterranean construction , 2010 .

[53]  Jorge S. Carlos,et al.  Real climate experimental study of two double window systems with preheating of ventilation air , 2010 .

[54]  S. Lykoudis,et al.  Experimental work on a linked, dynamic and ventilated, wall component , 2004 .

[55]  Sreenivasaiah Purushothama Rao,et al.  Experimental determination of thermal performance of glazed façades with water film, under direct solar radiation in the tropics , 2011 .

[56]  A. Androutsopoulos,et al.  Investigation of the performance of a ventilated wall , 2011 .

[57]  P. H. Baker,et al.  PASLINK and dynamic outdoor testing of building components , 2008 .

[58]  Aris Tsangrassoulis,et al.  Integrated energetic approach for a controlable electrochromic device , 2004 .

[59]  J A Clarke,et al.  AN APPROACH TO THE CALIBRATION OF BUILDING ENERGY SIMULATION MODELS , 1993 .

[60]  C. Caruanaa,et al.  Overview of testing methodologies for thermally improved hollow- core concrete blocks , 2014 .

[61]  Emily M. Ryan,et al.  Validation of building energy modeling tools under idealized and realistic conditions , 2012 .

[62]  Jianing Zhao,et al.  Energy performance of a dual airflow window under different climates , 2010 .

[63]  Constantinos A. Balaras,et al.  Modeling large openings with COMIS , 1999 .

[64]  Aris Tsangrassoulis,et al.  On the air flow and radiation transfer through partly covered external building openings , 1997 .

[65]  Per Heiselberg,et al.  Verification of a simplified method for intelligent glazed façade design under different control strategies in a full-scale façade test facility: Preliminary results of a south facing single zone experiment for a limited summer period , 2014 .

[66]  Elena G. Dascalaki,et al.  Predicting single sided natural ventilation rates in buildings , 1995 .

[67]  G. M. Revel,et al.  Cool products for building envelope – Part II: Experimental and numerical evaluation of thermal performances , 2014 .

[68]  François Garde,et al.  On the thermal behaviour of roof-mounted radiant barriers under tropical and humid climatic conditions: modelling and empirical validation , 2003 .

[69]  E. Caamaño-Martín,et al.  Integral energy performance characterization of semi-transparent photovoltaic elements for building integration under real operation conditions , 2014 .

[70]  Jay Burch,et al.  Empirical validation of building energy-analysis simulation programs: a status report , 1982 .

[71]  Arnold Janssens,et al.  Full scale testing and dynamic data analysis for building energy performance assessment: state of the art , 2014 .

[72]  Paul Baker IQ-test: improving quality in testing and evaluation of solar and thermal characteristics of building components , 2004 .

[73]  H. Manz,et al.  An empirical validation of window solar gain models and the associated interactions , 2009 .

[74]  Po-Chun Chen,et al.  Heat insulation solar glass and application on energy efficiency buildings , 2014 .

[75]  Henrik Madsen,et al.  Identification of the main thermal characteristics of building components using MATLAB , 2008 .

[76]  Valentina Serra,et al.  Improving thermal comfort conditions by means of PCM glazing systems , 2013 .

[77]  R. Judkoff,et al.  Model Validation and Testing: The Methodological Foundation of ASHRAE Standard 140 , 2006 .

[78]  Valentina Serra,et al.  Experimental analysis of the energy performance of a full-scale PCM glazing prototype , 2014 .

[79]  Arnold Janssens,et al.  Zinc roofs: an evaluation based on test house measurements , 2003 .

[80]  Dirk Saelens,et al.  The inlet temperature as a boundary condition for multiple-skin facade modelling , 2004 .

[81]  Lorenzo Pagliano,et al.  Optimization of the Installation of an Earth-to-Air Heat Exchanger and Detailed Design of a Dedicated Experimental Set-Up , 2014 .

[82]  Jay Burch,et al.  Methodology for Validating Building Energy Analysis Simulations , 2008 .

[83]  J. J. Bloem,et al.  Evaluation of a PV-integrated building application in a well-controlled outdoor test environment , 2008 .

[84]  P. Wouters,et al.  The use of outdoor test cells for thermal and solar building research within the PASSYS project , 1993 .

[85]  P. H. Baker,et al.  Outdoor testing, analysis and modelling of building components , 2008 .

[86]  Cinzia Buratti,et al.  Effect of dynamic characteristics of building envelope on thermal-energy performance in winter conditions: In field experiment , 2014 .

[87]  P. H. Baker Evaluation of round-robin testing using the PASLINK test facilities , 2008 .

[88]  Gonzalo Guillén-Gosálbez,et al.  Multi-objective optimization of thermal modelled cubicles considering the total cost and life cycle environmental impact , 2015 .

[89]  André Bontemps,et al.  Thermal testing and numerical simulation of a prototype cell using light wallboards coupling vacuum isolation panels and phase change material , 2006 .

[90]  Fernanda Rodrigues,et al.  Development of a window shutter with phase change materials: Full scale outdoor experimental approach , 2015 .

[91]  Paul Strachan,et al.  Case studies of outdoor testing and analysis of building components , 2008 .

[92]  Frédéric Suard,et al.  DISTANCE AND SIMILARITY MEASURES FOR SENSORSSELECTION IN HEAVILY INSTRUMENTED BUILDINGS:APPLICATION TO THE INCAS PLATFORM , 2011 .

[93]  Kevin J. Lomas,et al.  Empirical validation of building energy simulation programs , 1997 .

[94]  V. Serra,et al.  Experimental evaluation of a climate façade: Energy efficiency and thermal comfort performance , 2010 .

[95]  Aris Tsangrassoulis,et al.  Theoretical and experimental analysis of daylight performance for various shading systems , 1996 .

[96]  Per Heiselberg,et al.  An Empirical Validation of Building Simulation Software for Modelling of Double-Skin Facade (DSF) , 2009 .

[97]  A. Campos-Celador,et al.  Ventilated active façades with PCM , 2013 .

[98]  Nader Sadegh,et al.  Calibration of a lumped simulation model for double-skin façade systems , 2004 .

[99]  Valentina Serra,et al.  A numerical model to evaluate the thermal behaviour of active transparent façades , 2011 .

[100]  Staf Roels,et al.  The effect of a reflective underlay on the global thermal behaviour of pitched roofs , 2011 .

[101]  Carsten Rode,et al.  Whole building hygrothermal simulation model , 2010 .

[102]  Shen Xu,et al.  Optimal PV cell coverage ratio for semi-transparent photovoltaics on office building facades in central China , 2014 .

[103]  Arnold Janssens,et al.  Effects of wind on the transmission heat loss in duo-pitched insulated roofs: A field study , 2007 .

[104]  T. Kalema,et al.  Effect of interior heat transfer coefficients on thermal dynamics and energy consumption , 1995 .

[105]  Aris Tsangrassoulis,et al.  Development of a control algorithm to optimize airflow rates through variable size windows , 2002 .