Ambient and fire behavior of eccentrically loaded elliptical slender concrete-filled tubular columns

Abstract This paper presents the results of an experimental program carried out on slender elliptical hollow section columns filled with concrete. Given the reduced number of experimental results found in the literature on concrete filled tubular columns with elliptical cross-section, the main objective of this paper is to compare the behavior of such innovative cross-sections under ambient and high temperatures. The test parameters covered in this experimental program were the load eccentricity (0, 20 and 50 mm) and the type of infill (plain concrete or bar-reinforced concrete). Six room temperature tests were performed, while other six tests were carried out at elevated temperatures, under both concentric and eccentric axial loads. Using the results of these tests, the current provisions of Eurocode 4 for room temperature and fire design were assessed, and a specific design proposal developed by the authors was evaluated.

[1]  Tak-Ming Chan,et al.  Bending strength of hot-rolled elliptical hollow sections , 2008 .

[2]  Leroy Gardner,et al.  Elastic buckling of elliptical tubes , 2008 .

[3]  Manuel L. Romero,et al.  Influence of Slenderness on High-Strength Rectangular Concrete-Filled Tubular Columns with Axial Load and Nonconstant Bending Moment , 2012 .

[4]  Tom Lennon Designers' guide to EN 1991-1-2, EN 1992-1-2, EN 1993-1-2 and EN 1994-1-2 : handbook for the fire design of steel, composite and concrete structures to the eurocodes , 2007 .

[5]  Nuno Silvestre,et al.  Buckling behaviour of elliptical cylindrical shells and tubes under compression , 2008 .

[6]  Tak-Ming Chan,et al.  Flexural Buckling of Elliptical Hollow Section Columns , 2009 .

[7]  Xianghe Dai,et al.  Shape effect on the behaviour of axially loaded concrete filled steel tubular stub columns at elevated temperature , 2012 .

[8]  Manuel L. Romero,et al.  Fire design method for bar-reinforced circular and elliptical concrete filled tubular columns , 2013 .

[9]  Tak-Ming Chan,et al.  Cross-section classification of elliptical hollow sections , 2007 .

[10]  Leroy Gardner,et al.  Lateral instability of elliptical hollow section beams , 2012 .

[11]  J. M. Portolésa,et al.  Influence of ultra-high strength infill in slender concrete-filled steel tubular columns , 2022 .

[12]  Manuel L. Romero,et al.  Advanced model for predicting the fire response of concrete filled tubular columns , 2010 .

[13]  Tak-Ming Chan,et al.  Structural design of elliptical hollow sections: a review , 2010 .

[14]  Tak-Ming Chan,et al.  Structural behaviour of elliptical hollow sections under combined compression and uniaxial bending , 2011 .

[15]  Tak-Ming Chan,et al.  Compressive resistance of hot-rolled elliptical hollow sections , 2008 .

[16]  Manuel L. Romero,et al.  Experimental study of high strength concrete-filled circular tubular columns under eccentric loading , 2011 .

[17]  Tom Scullion,et al.  Experimental study on performance of elliptical section steel columns, under hydrocarbon fire , 2011 .

[18]  Manuel L. Romero,et al.  Ultimate capacity of rectangular concrete-filled steel tubular columns under unequal load eccentricities , 2012 .

[19]  Manuel L. Romero,et al.  Fire behavior of axially loaded slender high strength concrete-filled tubular columns , 2011 .

[20]  Tom Scullion,et al.  Effect of axial restraint on the performance of Elliptical Hollow Section steel columns, in hydrocarbon fire , 2011 .

[21]  Reinhard Bergmann,et al.  Design guide for concrete filled hollow section columns under static and seismic loading , 1995 .

[22]  Leroy Gardner,et al.  Testing and analysis of concrete-filled elliptical hollow sections , 2008 .

[23]  Jianqiao Ye,et al.  An experimental study on elliptical concrete filled columns under axial compression , 2013 .

[24]  Tak-Ming Chan,et al.  Shear response of elliptical hollow sections , 2008 .

[25]  Jeffrey A. Packer,et al.  Tests and design of concrete-filled elliptical hollow section stub columns , 2009 .

[26]  Leroy Gardner,et al.  Behaviour of Axially Loaded Concrete Filled Stainless Steel Elliptical Stub Columns , 2010 .

[27]  Leroy Gardner,et al.  Fire behaviour of concrete filled elliptical steel columns , 2011 .

[28]  Manuel L. Romero,et al.  Simple calculation model for evaluating the fire resistance of unreinforced concrete filled tubular columns , 2012 .

[29]  Tom Scullion,et al.  Finite element numerical evaluation of elliptical hollow section steel columns in fire , 2012 .

[30]  Chanakya Arya,et al.  Eurocodes 2: Design of concrete structures , 2009 .

[31]  Xianghe Dai,et al.  Numerical modelling of the axial compressive behaviour of short concrete-filled elliptical steel columns , 2010 .

[32]  Tak-Ming Chan,et al.  Structural response of concrete-filled elliptical steel hollow sections under eccentric compression , 2012 .

[33]  K. F. Chung,et al.  Composite column design to Eurocode 4 : based on DD ENV 1994-1-1: 1994 Eurocode 4: design of composite steel and concrete structures: part 1.1: general rules and rules for buildings , 1994 .