Permanent-Magnet Synchronous Generator Supplying an Isolated Load

The steady-state and transient performance of a surface-inset permanent-magnet synchronous generator (PMSG) feeding an isolated load is studied using a coupled-circuit, time-stepping, two-dimensional finite-element analysis. Nonlinearities in the field and electric circuit are taken into consideration and both passive ac load and bridge rectifier dc load operating conditions are analyzed. The main contribution of this paper is the quantitative analysis of voltage and current harmonics, as well as the study of short-circuit performance. The computed results have been verified by experiments on a 2.5 kVA generator.

[1]  T. S. Low,et al.  Performance and application of multistacked imbricated permanent magnet generators , 1983 .

[2]  S. Williamson,et al.  Time-stepping finite element analysis for a synchronous generator feeding a rectifier load , 1995 .

[3]  L. L. Lai,et al.  Performance of a three-phase AC generator with inset NdFeB permanent-magnet rotor , 2004 .

[4]  L. L. Lai,et al.  Analysis of a stand-alone permanent-magnet synchronous generator using a time-stepping coupled field-circuit method , 2005 .

[5]  L. L. Lai,et al.  Permanent-magnet synchronous generator with inset rotor for autonomous power-system applications , 2004 .

[6]  T. S. Radwan,et al.  Modelling and controller design of an isolated diesel engine permanent magnet synchronous generator , 1996 .

[7]  A. J. Mitcham,et al.  Permanent magnet generator options for the More Electric Aircraft , 2002 .

[8]  Luiz Lebensztajn,et al.  Analysis of short-circuit transients of a PM machine , 1997, 1997 IEEE International Electric Machines and Drives Conference Record.

[9]  Olorunfemi Ojo,et al.  Investigation into the performance characteristics of an interior permanent magnet generator including saturation effects , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[10]  Albert Malvino,et al.  Electronic Principles , 1979 .

[11]  Loi Lei Lai,et al.  Power System Restructuring and Deregulation , 2001 .

[12]  E. Spooner,et al.  Capacitor-assisted excitation of permanent-magnet generators , 1998 .

[13]  Min Dai,et al.  Design and analysis of 42-V permanent-magnet generator for automotive applications , 2003 .

[14]  L. Lai Power system restructuring and deregulation : trading, perfomance and information technology , 2001 .

[15]  B. J. Chalmers,et al.  An axial-flux permanent-magnet generator for a gearless wind energy system , 1999 .

[16]  Jean-Louis Coulomb,et al.  A time-stepped finite-element simulation of a symmetrical short-circuit in a synchronous machine , 1994 .

[17]  B. J. Chalmers Performance of interior-type permanent-magnet alternator , 1994 .

[18]  D. C. Macdonald,et al.  Finite-element simulation of a generator on load during and after a three-phase fault , 1992 .

[19]  E. Muljadi,et al.  Axial flux, modular, permanent-magnet generator with a toroidal winding for wind turbine applications , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).