Analysis and Comparison of the Displacement Amplifiers with a Generalized Mathematical Model

The bridge-type amplifier and the lever-type amplifier are the two frequently used displacement amplifiers in the precision engineering. However, to the knowledge of the authors, the analysis and the performance comparison between the two amplifiers was not frequently reported, which is instrumental in realizing and selecting the displacement amplifiers in the practice application. To this end, the two types mechanisms are analyzed and compared with a compliance matrix based model. Via the analysis and comparison, some interesting results which are significant for the amplifiers are founded: 1). The amplification ratio is related to the input displacement when the elastic load is applied; 2) The limited amplification ratio phenomenon is observed in the bridge-type mechanism but also the lever-type one; 3) The comparison of the flexure hinges design for the two amplifiers are presented; 4) The load capacity of the two amplifiers are first analyzed and compared in this paper. Finally, the accuracy of the modeling is verified by FEA simulation studies.

[1]  Hai-Jun Su,et al.  A Symbolic Formulation for Analytical Compliance Analysis and Synthesis of Flexure Mechanisms. , 2012, Journal of mechanical design.

[2]  Zhijiang Du,et al.  Development of a highly efficient bridge-type mechanism based on negative stiffness , 2017 .

[3]  D. Gweon,et al.  Optimal design and experiment of a three-axis out-of-plane nano positioning stage using a new compact bridge-type displacement amplifier. , 2013, The Review of scientific instruments.

[4]  Jiong Tang,et al.  Design of a linear-motion dual-stage actuation system for precision control , 2009 .

[5]  Dan Zhang,et al.  Design and analysis of a three-dimensional bridge-type mechanism based on the stiffness distribution , 2018 .

[6]  Qingsong Xu,et al.  Design and Analysis of a Totally Decoupled Flexure-Based XY Parallel Micromanipulator , 2009, IEEE Transactions on Robotics.

[7]  X. Ding,et al.  A screw theory of static beams , 2001, Proceedings 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems. Expanding the Societal Role of Robotics in the the Next Millennium (Cat. No.01CH37180).

[8]  Qingsong Xu,et al.  Analytical modeling, optimization and testing of a compound bridge-type compliant displacement amplifier , 2011 .

[9]  Nicolae Lobontiu,et al.  Compliance-based matrix method for modeling the quasi-static response of planar serial flexure-hinge mechanisms , 2014 .

[10]  Qingsong Xu,et al.  Design and control of a novel piezo-driven XY parallel nanopositioning stage , 2017 .

[11]  G. Palli Intelligent Robots And Systems , 1993, Proceedings of 1993 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS '93).

[12]  Qingsong Xu,et al.  Design and Development of a Flexure-Based Dual-Stage Nanopositioning System With Minimum Interference Behavior , 2012, IEEE Transactions on Automation Science and Engineering.

[13]  Mohammad Javad Nategh,et al.  An elastokinematic solution to the inverse kinematics of microhexapod manipulator with flexure joints of varying rotation center , 2016 .

[14]  Nicolae Lobontiu,et al.  Corner-Filleted Flexure Hinges , 2001 .

[15]  Dae-Gab Gweon,et al.  Analysis and design of a cartwheel-type flexure hinge , 2013 .

[16]  David Zhang,et al.  Closed-form compliance equations of filleted V-shaped flexure hinges for compliant mechanism design , 2010 .

[17]  Guangbo Hao,et al.  Constraint-force-based approach of modelling compliant mechanisms: Principle and application , 2017 .

[18]  Qingsong Xu,et al.  Design and fabrication of a new micro-injector driven by piezoelectric actuator , 2017, 2017 International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS).

[19]  Li Wei,et al.  Quasi-static analysis of a compliant tripod stage with plane compliant lever mechanism , 2017 .

[20]  Yangmin Li,et al.  A novel flexure-based dual-arm robotic system for high-throughput biomanipulations on micro-fluidic chip , 2013, 2013 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[21]  Xiao-Ping S Su,et al.  Design of compliant microleverage mechanisms , 2001 .

[22]  Xinbo Huang,et al.  A new generalized model for elliptical arc flexure hinges. , 2008, The Review of scientific instruments.

[23]  Seung-Bok Choi,et al.  A magnification device for precision mechanisms featuring piezoactuators and flexure hinges: Design and experimental validation , 2007 .

[24]  Pengbo Liu,et al.  A new model analysis approach for bridge-type amplifiers supporting nano-stage design , 2016 .

[25]  Chen Tao,et al.  Design and research of miniaturization two-dimensional micro-positioning platform based on parallel sheet plate flexible decoupling beams , 2013, 2013 International Conference on Manipulation, Manufacturing and Measurement on the Nanoscale.

[26]  Nicolae Lobontiu,et al.  Substructure compliance matrix model of planar branched flexure-hinge mechanisms: Design, testing and characterization of a gripper , 2015 .