Wireless tissue palpation: Proof of concept for a single degree of freedom

Palpating tissues and organs to identify hidden tumors or to detect buried vessels is not a viable option in laparoscopic surgery due to lack of force feedback. So far, research toward restoring tactile and kinesthetic sensations in minimally invasive surgery has focused on the distal sensing element or on the proximal rendering of haptic cues. In this work we present a pilot study to assess the feasibility of wireless tissue palpation, where a magnetic device is deployed through a standard surgical trocar and operated to perform tissue palpation without requiring a dedicated entry port. The setup consists of a wireless intra-body device and an external robotic manipulator holding a load cell and a permanent magnet. Embedded in the wireless cylindrical device (12.7 mm in diameter and 27.5 mm in height) is a sensing module, a wireless microcontroller, a battery and a permanent magnet. This preliminary study assessed the precision in reconstructing the indentation depth based on magnetic field measurements at the wireless device (i.e., 0.1 mm accuracy). Experimental trials demonstrated the effectiveness of wireless vertical indentation in detecting the elastic modulus of three different silicone tissue simulators (elastic modulus ranging from 50 kPa to 93 kPa), showing a maximum relative error below 3%. Finally, wireless palpation was used to identify differences in tissue stiffness from a lump embedded into a porcine liver. The reported results have the potential to open a new paradigm in the field of palpation devices, where direct physical connection across the abdominal wall is no longer required.

[1]  Stefano Gidaro,et al.  The future of telesurgery: a universal system with haptic sensation. , 2012, Journal of the Turkish German Gynecological Association.

[2]  M. Schijven,et al.  The value of haptic feedback in conventional and robot-assisted minimal invasive surgery and virtual reality training: a current review , 2009, Surgical Endoscopy.

[3]  Paolo Dario,et al.  Transmission Power Requirements for Novel ZigBee Implants in the Gastrointestinal Tract , 2008, IEEE Transactions on Biomedical Engineering.

[4]  Kaspar Althoefer,et al.  Rolling Indentation Probe for Tissue Abnormality Identification During Minimally Invasive Surgery , 2011, IEEE Transactions on Robotics.

[5]  Shane Farritor,et al.  Modeling, Analysis, and Experimental Study of In Vivo Wheeled Robotic Mobility , 2006, IEEE Transactions on Robotics.

[6]  Metin Sitti,et al.  Design and Rolling Locomotion of a Magnetically Actuated Soft Capsule Endoscope , 2012, IEEE Transactions on Robotics.

[7]  Jaydev P. Desai,et al.  Development of In Vivo Constitutive Models for Liver: Application to Surgical Simulation , 2011, Annals of Biomedical Engineering.

[8]  Nabil Simaan,et al.  Algorithms for autonomous exploration and estimation in compliant environments , 2012, Robotica.

[9]  Allison M. Okamura,et al.  Human vs. robotic tactile sensing: Detecting lumps in soft tissue , 2010, 2010 IEEE Haptics Symposium.

[10]  A. L. Trejos,et al.  Feasibility of locating tumours in lung via kinaesthetic feedback , 2008, The international journal of medical robotics + computer assisted surgery : MRCAS.

[11]  P. Dario,et al.  An advanced robot system for automated diagnostic tasks through palpation , 1988, IEEE Transactions on Biomedical Engineering.

[12]  Pietro Valdastri,et al.  Trans-abdominal Active Magnetic Linkage for robotic surgery: Concept definition and model assessment , 2012, 2012 IEEE International Conference on Robotics and Automation.

[13]  Bernhard Kübler,et al.  Development of actuated and sensor integrated forceps for minimally invasive robotic surgery , 2006 .

[14]  Jaydev P. Desai,et al.  A Compact and Modular Laparoscopic Grasper With Tridirectional Force Measurement Capability , 2008 .

[15]  T. Frank,et al.  Mechanical properties of the human abdominal wall measured in vivo during insufflation for laparoscopic surgery , 2006, Surgical Endoscopy And Other Interventional Techniques.

[16]  Anubhav Tripathi,et al.  Localization of magnetic pills , 2011, Proceedings of the National Academy of Sciences.

[17]  M. Mon-Williams,et al.  Reviewing the technological challenges associated with the development of a laparoscopic palpation device , 2012, The international journal of medical robotics + computer assisted surgery : MRCAS.

[18]  Cagatay Basdogan,et al.  A robotic indenter for minimally invasive measurement and characterization of soft tissue response , 2007, Medical Image Anal..

[19]  Paolo Dario,et al.  Robotic magnetic steering and locomotion of capsule endoscope for diagnostic and surgical endoluminal procedures , 2009, Robotica.

[20]  Robert D. Howe,et al.  Remote palpation technology , 1995 .

[21]  Jake J. Abbott,et al.  Control of untethered magnetically actuated tools using a rotating permanent magnet in any position , 2012, 2012 IEEE International Conference on Robotics and Automation.

[22]  John Kenneth Salisbury,et al.  In Vivo Data Acquisition Instrument for Solid Organ Mechanical Property Measurement , 2001, MICCAI.

[23]  S. Omata,et al.  Application of a new tactile sensor to thoracoscopic surgery: experimental and clinical study. , 1995, The Annals of thoracic surgery.

[24]  R Westphal,et al.  Using robotic systems in order to determine biomechanical properties of soft tissues. , 2008, Studies in health technology and informatics.

[25]  Hongbin Liu,et al.  Miniature 3-Axis Distal Force Sensor for Minimally Invasive Surgical Palpation , 2012, IEEE/ASME Transactions on Mechatronics.

[26]  Pietro Valdastri,et al.  Real-Time Pose Detection for Magnetic Medical Devices , 2013, IEEE Transactions on Magnetics.

[27]  Mark Rentschler,et al.  Vision and Task Assistance Using Modular Wireless In Vivo Surgical Robots , 2009, IEEE Transactions on Biomedical Engineering.

[28]  G Hirzinger,et al.  Development of actuated and sensor integrated forceps for minimally invasive robotic surger , 2005, The international journal of medical robotics + computer assisted surgery : MRCAS.

[29]  Blake Hannaford,et al.  Biomechanical properties of abdominal organs in vivo and postmortem under compression loads. , 2008, Journal of biomechanical engineering.