Critical Excitation of the Fundamental Quasi-Shear Mode Wave in Waveguide Bars for Elevated Temperature Applications

The safety of critical pressure equipment in elevated temperature is increasingly important. Moreover, the on-line monitoring method is potentially useful to improve their safety. A waveguide bar system can enable monitoring of critical equipment working in elevated temperature using reliable ultrasonic technology. Among the waveguide bar system, the matching mechanism of the transducer and the waveguide bar is crucial to propagate the pure fundamental quasi-shear mode (shorten for SH0*) wave. In the present research, the loading line sources that can excite pure SH0* wave are investigated and the anti-plane shear loading source is selected. The critical values about the geometric dimensions of the junctions between the piezoelectric transducer and the waveguide bar are explored by simulation and experiments. On the condition that the excitation sources satisfy the critical values, the loading can be approximated to an anti-plane shear one to excite the pure SH0* wave. Some waveguide bar systems are designed based on the simulated critical values and some experiments at high temperature are carried out. The experimental results verify that the designed waveguide bar systems can excite the pure SH0* wave at elevated temperatures, which verify the reliability of the simulated critical results.

[1]  S. Dong,et al.  Excitation of fundamental shear horizontal wave by using face-shear (d36) piezoelectric ceramics , 2016, 1603.05077.

[2]  F. Cegla,et al.  Energy concentration at the center of large aspect ratio rectangular waveguides at high frequencies. , 2008, The Journal of the Acoustical Society of America.

[3]  Dong-Jin Kim,et al.  High-temperature ultrasonic thickness monitoring for pipe thinning in a flow-accelerated corrosion proof test facility , 2017 .

[4]  Z. Fan,et al.  Numerical studies of nonlinear ultrasonic guided waves in uniform waveguides with arbitrary cross sections , 2016 .

[5]  M Castaings,et al.  Torsional waves propagation along a waveguide of arbitrary cross section immersed in a perfect fluid. , 2008, The Journal of the Acoustical Society of America.

[6]  Jianming Gong,et al.  Measurement of Local Creep Deformation in Cross-Weld Specimen by Optical Fiber Marking and Remote Monitoring , 2002 .

[7]  J. Jia,et al.  Excitation of a Fundamental Shear Horizontal Wave Using a Line Source , 2019 .

[8]  Mark J. Schulz,et al.  Piezoelectric Materials at Elevated Temperature , 2003 .

[9]  Christophe Travaglini,et al.  Feasibility of high frequency guided wave crack monitoring , 2017 .

[10]  Mario Bergés,et al.  Robust ultrasonic damage detection under complex environmental conditions using singular value decomposition. , 2015, Ultrasonics.

[11]  Y. Ono,et al.  Aluminum buffer rods for ultrasonic monitoring at elevated temperatures , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  F. Cegla,et al.  Acoustic waveguides: An attractive alternative for accurate and robust contact thermometry , 2018 .

[13]  Yimin Wei,et al.  Longitudinal wave propagation in a rod with variable cross-section , 2014 .

[14]  Shan-Tung Tu,et al.  Design of Waveguide Bars for Transmitting a Pure Shear Horizontal Wave to Monitor High Temperature Components , 2017, Materials.

[15]  Renaldas Raisutis,et al.  Propagation of Ultrasonic Shear Horizontal Waves in Rectangular Waveguides , 2016 .

[16]  Shenfang Yuan,et al.  Analytical insight into "breathing" crack-induced acoustic nonlinearity with an application to quantitative evaluation of contact cracks. , 2018, Ultrasonics.

[17]  Christoph Schaal,et al.  Damage detection in multi-wire cables using guided ultrasonic waves , 2016 .

[18]  Hui Wang,et al.  On‐line prognosis of fatigue crack propagation based on Gaussian weight‐mixture proposal particle filter , 2018, Ultrasonics.

[19]  Qiang Wang,et al.  Modeling nonlinearities of ultrasonic waves for fatigue damage characterization: theory, simulation, and experimental validation. , 2014, Ultrasonics.

[20]  Hongchen Miao,et al.  Excitation and reception of pure shear horizontal waves by using face-shear d24 mode piezoelectric wafers , 2016 .

[21]  H. Sohn,et al.  Second harmonic generation at fatigue cracks by low-frequency Lamb waves: experimental and numerical studies , 2018 .

[22]  Yanxun Xiang,et al.  Creep damage characterization using nonlinear ultrasonic guided wave method: A mesoscale model , 2014 .

[23]  P Cawley,et al.  High-temperature (>500°c) wall thickness monitoring using dry-coupled ultrasonic waveguide transducers , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  Xia Zhao,et al.  Distributed structural health monitoring system based on smart wireless sensor and multi-agent technology , 2006 .