Recent activities at BIPM in the field of stabilized lasers-radiations recommended for the definition of the meter

The results of interconnectional comparisons of iodine-stabilized He-Ne lasers at lambda =633 nm between Bureau International des Poids et Mesures (BIPM) and 11 national laboratories are presented. The measured frequency differences were all within +or-3 parts in 10/sup 11/. Investigations concerning He-Ne lasers at lambda =612 nm using internal or external iodine cells are discussed. The frequency reproducibility is limited by, among other things the quality of the iodine cells. Therefore, the contamination of iodine cells has been studied using laser-induced fluorescence. First results obtained on the green line of He-Ne at lambda =543 nm stabilized on iodine are presented. The frequency repeatability between two such systems was (14+or-5) kHz. >

[1]  J. Helmcke,et al.  International intercomparison of the wavelength of iodine-stabilized lasers , 1976, IEEE Transactions on Instrumentation and Measurement.

[2]  J. Helmcke,et al.  I2 Stabilized He-Ne Lasers at 612 nm , 1980, IEEE Transactions on Instrumentation and Measurement.

[3]  New measurement of the Rydberg constant by two-photon spectroscopy of hydrogen Rydberg states. , 1989 .

[4]  F. Bertinetto,et al.  Comparison between the 127I2 Stabilized He-Ne Lasers at 633 nm and 612 nm of the BIPM and the IMGC , 1983, IEEE Transactions on Instrumentation and Measurement.

[5]  N Brown,et al.  International Intercomparison of Iodine-Stabilized Helium-Neon Lasers at 633 nm Involving Ten Standards Laboratories , 1987 .

[6]  M. Gläser An improved He-Ne laser at λ = 612 nm, stabilized by means of an external absorption cell , 1986 .

[7]  S. Iwasaki,et al.  Comparison of the 127I2 Stabilized He-Ne Lasers at 633 nm Wavelength of the National Research Laboratory of Metrology of Japan and the Bureau International des Poids et Mesures , 1989 .

[8]  L. Pendrill,et al.  Intercomparison of Optical Frequencies at 473 THz of 127I2-stabilized He-Ne Lasers from the Swedish National Testing and Research Institute and the Bureau International des Poids et Mesures , 1991 .

[9]  Lennart Robertsson,et al.  Frequency-stabilized 543 nm HeNe laser systems: A new candidate for the realization of the metre? , 1989 .

[10]  Frank Spieweck,et al.  Influence of Small Impurities in Absorption Cells of I2 Stabilized Lasers upon Their Frequency , 1985, IEEE Transactions on Instrumentation and Measurement.

[11]  S Fredin-Picard,et al.  A Study of Contamination in 127I2 Cells Using Laser-Induced Fluorescence , 1989 .

[12]  J. Chartier Results of international comparisons using methane-stabilized He-Ne lasers at 3.39 μm and iodine-stabilized He-Ne lasers at 633 nm , 1983, IEEE Transactions on Instrumentation and Measurement.

[13]  R. Felder,et al.  He-Ne Lasers Stabilized by Saturated Absorption in Iodine at 612 nm , 1980, IEEE Transactions on Instrumentation and Measurement.

[14]  A. Razet,et al.  On the hyperfine structure of 127I2 lines at the 543 nm wavelength of the HeNe laser , 1990 .