Flow-Diverter Silk Stent for the Treatment of Intracranial Aneurysms: 1-year Follow-Up in a Multicenter Study

BACKGROUND AND PURPOSE: FD stent placement is a promising therapy for challenging intracranial aneurysms. Long-term evaluations about angiographic and morphologic results are still missing. This is the aim of this multicenter series. MATERIALS AND METHODS: We report our experience and 1-year FU in a retrospective chart review of 65 consecutive subjects with 77 unruptured or recanalized aneurysms that were treated with Silk FD stents at 6 centers in France. Both angiographic and clinical results were recorded before treatment and at 6 and 12 months after treatment. At the 12-month FU, relationships between angiographic aneurysm occlusion and shrinkage of the thrombosed aneurysm sac were evaluated. RESULTS: Stent deployment was achieved in 64 cases (98.5%) and failed in 1 case (1.5%). Seven misdeployments of the Silk stent caused the occlusion of 6 parent arteries. Overall acute/subacute procedural morbidity was 7.7%, and mortality was zero. Delayed complications were observed in 10.9% of subjects. At the 6-month FU, permanent morbidity was 7.8% and mortality was 3%. Complete occlusion occurred within 6 months in 68% of aneurysms and within 12 months after treatment in 84.5% of aneurysms. At the 12-month FU, in angiographically complete occluded aneurysms, MR imaging/CT analysis showed the complete disappearance of the thrombosed aneurysm in 30% of cases and partial shrinkage in 52%; furthermore, thrombosed aneurysms were stable in 11% of cases and enlarged in 7%. CONCLUSIONS: The Silk stent is an effective tool for the treatment of challenging aneurysms because it allows complete occlusion in most cases 1 year after treatment. Permanent morbidity was 7.8%, and mortality was 3%.

[1]  V. Dousset,et al.  Perianeurysmal Brain Inflammation after Flow-Diversion Treatment , 2011, American Journal of Neuroradiology.

[2]  P. Lylyk,et al.  The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial , 2010, American Journal of Neuroradiology.

[3]  C. Putman,et al.  Aneurysm Rupture Following Treatment with Flow-Diverting Stents: Computational Hemodynamics Analysis of Treatment , 2010, American Journal of Neuroradiology.

[4]  S. Renowden,et al.  Intra-Aneurysmal Thrombosis as a Possible Cause of Delayed Aneurysm Rupture after Flow-Diversion Treatment , 2010, American Journal of Neuroradiology.

[5]  I. Maldonado,et al.  Neuroform Stent−Assisted Coiling of Unruptured Intracranial Aneurysms: Short- and Midterm Results from a Single-Center Experience with 68 Patients , 2010, American Journal of Neuroradiology.

[6]  F. Bonneville,et al.  Parent artery occlusion is not obsolete in giant aneurysms of the ICA. Experience with very-long-term follow-up , 2011, Neuroradiology.

[7]  R. Blanc,et al.  An in vitro study of silk stent morphology , 2011, Neuroradiology.

[8]  S. Greenberg,et al.  Personalized Approaches to Clopidogrel Therapy: Are We There Yet? , 2010, Stroke.

[9]  J. Pruvo,et al.  Flow-Diverter Stent for the Endovascular Treatment of Intracranial Aneurysms: A Prospective Study in 29 Patients With 34 Aneurysms , 2010, Stroke.

[10]  Jacqueline Birks,et al.  Early Experience in the Treatment of Intra-Cranial Aneurysms by Endovascular Flow Diversion: A Multicentre Prospective Study , 2010, PloS one.

[11]  Isabel Wanke,et al.  High-Profile Flow Diverter (Silk) Implantation in the Basilar Artery: Efficacy in the Treatment of Aneurysms and the Role of the Perforators , 2010, Stroke.

[12]  Z Kulcsar,et al.  Treatment of Intracranial Aneurysms by Functional Reconstruction of the Parent Artery: The Budapest Experience with the Pipeline Embolization Device , 2010, American Journal of Neuroradiology.

[13]  Raphaël Blanc,et al.  Stent-Assisted Coiling of Intracranial Aneurysms: Clinical and Angiographic Results in 216 Consecutive Aneurysms , 2010, Stroke.

[14]  Bernd Turowski,et al.  Early fatal hemorrhage after endovascular cerebral aneurysm treatment with a flow diverter (SILK-Stent) , 2010, Neuroradiology.

[15]  Carlos Miranda,et al.  CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICE: THE BUENOS AIRES EXPERIENCE , 2009, Neurosurgery.

[16]  Liliana Cesar,et al.  An Original Flow Diversion Device for the Treatment of Intracranial Aneurysms: Evaluation in the Rabbit Elastase-Induced Model , 2009, Stroke.

[17]  R. Willinsky,et al.  Wall enhancement, edema, and hydrocephalus after endovascular coil occlusion of intradural cerebral aneurysms. , 2008, Journal of neurosurgery.

[18]  H. Zeumer,et al.  Long-Term Follow-Up of Cerebral Aneurysms after Endovascular Therapy–Prediction and Outcome of Retreatment , 2007, American Journal of Neuroradiology.

[19]  Howard A Riina,et al.  NEUROFORM STENT‐ASSISTED COIL EMBOLIZATION OF WIDE‐NECK INTRACRANIAL ANEURYSMS: STRATEGIES IN STENT DEPLOYMENT AND MIDTERM FOLLOW‐UP , 2007, Neurosurgery.

[20]  A. Wakhloo,et al.  Alteration of hemodynamics in aneurysm models by stenting: Influence of stent porosity , 1997, Annals of Biomedical Engineering.

[21]  D. Nichols,et al.  Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment , 2003, The Lancet.

[22]  A. Olivi,et al.  Acute vasogenic edema induced by thrombosis of a giant intracranial aneurysm: a cause of pseudostroke after therapeutic occlusion of the parent vessel. , 2003, AJNR. American journal of neuroradiology.

[23]  Daniel Roy,et al.  Endovascular Treatment of Unruptured Aneurysms , 2001, Stroke.