Influence of FBG sensors length on temperature measures in laser-irradiated pancreas: Theoretical and experimental evaluation

Temperature distribution T(x,y,z,t) in tissue undergoing Laser-induced Interstitial Thermotherapy (LITT) plays a crucial role on treatment outcome. Theoretical and experimental assessment of temperature on ex vivo laser-irradiated pancreas is presented. The aim of this work is to assess the influence of thermometers dimensions on temperature measures during LITT. T(x,y,z,t) inside tissue is monitored by optical sensors, i.e., Fiber Bragg Gratings (FBGs): three FBGs with lengths of 10 mm and nine FBGs of 1 mm, at different distances (2 mm, 5 mm and 10 mm) and different quotes (0 mm, 2 mm and 4 mm) from the laser fiber tip are used. Theoretical punctual T(x,y,z,t) is averaged out on both 10 mm and 1 mm in order to compare numerical predictions with experimental data. Results demonstrate the influence of FBG length on T(x,y,z,t) measures. This phenomenon depends on the distance between sensor and applicator: it is particularly significant close to the applicator tip (2 mm) because of the high spatial T(x,y,z,t) gradient within the tissue. Both theoretical results and experimental ones show that just at a distance of 10 mm from the tip, differences between T(x,y,z,t) provided by FBGs of 10 mm and 1 mm are negligible.

[1]  J. Werner,et al.  Coagulation and temperature distribution in Nd: YAG interstitial laser thermotherapy: an in vitro animal study , 2003, Lasers in Medical Science.

[2]  L Battista,et al.  An air flow sensor for neonatal mechanical ventilation applications based on a novel fiber-optic sensing technique. , 2013, The Review of scientific instruments.

[3]  Andre Roggan,et al.  Laser-Induced Interstitial Thermotherapy , 1995 .

[5]  A L McKenzie,et al.  Physics of thermal processes in laser-tissue interaction. , 1990, Physics in medicine and biology.

[6]  Tingyun Wang,et al.  Fully distributed chirped FBG sensor and application in laser-induced interstitial thermotherapy , 2009, 2009 Asia Communications and Photonics conference and Exhibition (ACP).

[7]  Sergio Silvestri,et al.  Optical-Fiber Measurement Systems for Medical Applications , 2011 .

[8]  R Jason Stafford,et al.  Laser-induced thermal therapy for tumor ablation. , 2010, Critical reviews in biomedical engineering.

[9]  Sergio Silvestri,et al.  An optical fiber based flow transducer for infant ventilation: Measurement principle and calibration , 2011, 2011 IEEE International Symposium on Medical Measurements and Applications.

[10]  Fabrice Manns,et al.  Thermal analysis of laser interstitial thermotherapy in ex vivo fibro-fatty tissue using exponential functions , 2004, Physics in medicine and biology.

[11]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[12]  Sergio Silvestri,et al.  A high sensitivity fiber optic macro-bend based gas flow rate transducer for low flow rates: theory, working principle, and static calibration. , 2013, The Review of scientific instruments.

[13]  R. Issels,et al.  Hyperthermia in oncology. , 2001 .

[14]  Sergio Silvestri,et al.  Theoretical assessment of principal factors influencing laser interstitial thermotherapy outcomes on pancreas , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[15]  John G. Webster,et al.  Expanding the Bioheat Equation to Include Tissue Internal Water Evaporation During Heating , 2007, IEEE Transactions on Biomedical Engineering.

[16]  Sergio Silvestri,et al.  Theoretical Analysis and Experimental Evaluation of Laser-Induced Interstitial Thermotherapy in Ex Vivo Porcine Pancreas , 2012, IEEE Transactions on Biomedical Engineering.

[17]  Sergio Silvestri,et al.  Laser Interstitial Thermotherapy for pancreatic tumor ablation: Theoretical model and experimental validation , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[18]  M D Sherar,et al.  Temperature measurement artefacts of thermocouples and fluoroptic probes during laser irradiation at 810 nm. , 2001, Physics in medicine and biology.

[19]  Sergio Silvestri,et al.  A novel target-type low pressure drop bidirectional optoelectronic air flow sensor for infant artificial ventilation: measurement principle and static calibration. , 2011, The Review of scientific instruments.