Research on False Data Injection Attacks in VSC-HVDC Systems

The false data injection (FDI) attack is a crucial form of cyber-physical security problems facing cyber-physical power systems. However, there is no research revealing the problem of FDI attacks facing voltage source converter based high voltage direct current transmission (VSC-HVDC) systems. Firstly, the general form of the model of FDI attack strategies is proposed and the essence of the problem of FDI attack strategies is further analyzed. Moreover, the model of FDI attack strategies aiming at disrupting the operation security of converter stations in VSC-HVDC systems is proposed and its solving algorithm is then presented. And finally, the modified IEEE-14 bus system is utilized to reveal the problem of FDI attacks facing VSC-HVDC systems, demonstrating that attackers are capable of disrupting the operation security of converter stations in VSC-HVDC systems by FDI attacks.

[1]  Zuyi Li,et al.  Local Load Redistribution Attacks in Power Systems With Incomplete Network Information , 2014, IEEE Transactions on Smart Grid.

[2]  Su Shen,et al.  Attacker's Perspective Based Analysis on Cyber Attack Mode to Cyber-Physical System , 2014 .

[3]  Liyan Jia,et al.  On the nonlinearity effects on malicious data attack on power system , 2012, 2012 IEEE Power and Energy Society General Meeting.

[4]  Dai Dangdang,et al.  Survey of False Data Injection Attacks in Power Transmission Systems , 2016 .

[5]  Ye Xiamin Propagation Mechanism of Cyber Physical Security Risks in Power Systems , 2015 .

[6]  Lang Tong,et al.  On Topology Attack of a Smart Grid: Undetectable Attacks and Countermeasures , 2013, IEEE Journal on Selected Areas in Communications.

[7]  Lang Tong,et al.  Malicious Data Attacks on the Smart Grid , 2011, IEEE Transactions on Smart Grid.

[8]  Zuyi Li,et al.  Modeling of Local False Data Injection Attacks With Reduced Network Information , 2015, IEEE Transactions on Smart Grid.

[9]  Zheng Jian-chao Over-current Failure Mechanism of IGBT Within Voltage Source Converter Based High Voltage Direct Current , 2009 .

[10]  Zuyi Li,et al.  False Data Attacks Against AC State Estimation With Incomplete Network Information , 2017, IEEE Transactions on Smart Grid.

[11]  R. Belmans,et al.  Generalized Steady-State VSC MTDC Model for Sequential AC/DC Power Flow Algorithms , 2012, IEEE Transactions on Power Systems.

[12]  Gabriela Hug,et al.  Vulnerability Assessment of AC State Estimation With Respect to False Data Injection Cyber-Attacks , 2012, IEEE Transactions on Smart Grid.

[13]  Ronnie Belmans,et al.  Generalized steady-state VSC MTDC model for sequential AC/DC power flow algorithms , 2013, 2013 IEEE Power & Energy Society General Meeting.

[14]  Zhao Yang Dong,et al.  A Review of False Data Injection Attacks Against Modern Power Systems , 2017, IEEE Transactions on Smart Grid.

[15]  A.G. Exposito,et al.  Voltage Source Converter Modeling for Power System State Estimation: STATCOM and VSC-HVDC , 2008, IEEE Transactions on Power Systems.