In vivo myocardial kinetics of air-filled albumin microbubbles during myocardial contrast echocardiography. Comparison with radiolabeled red blood cells.

Myocardial contrast echocardiography (MCE) is a new technique for assessing myocardial perfusion that uses intracoronary injections of microbubbles of air. Because these microbubbles have a mean diameter of 4.3 +/- 0.3 microns and an intravascular rheology similar to that of red blood cells (RBCs), we hypothesized that their mean myocardial transit rates recorded on echocardiography would provide an estimation of regional myocardial blood flow in the in vivo beating heart. Accordingly, blood flow to the left anterior descending coronary artery (LAD) of 12 open-chest anesthetized dogs (group I) was adjusted to 4 to 6 flows (total of 60 flows), and microbubbles and radiolabeled RBCs were injected into the LAD in a random order at each stage. The mean myocardial RBC transit rates were measured by fitting a gamma-variate function to time-activity plots generated by placing a miniature CsI2 probe over the anterior surface of the heart, and the mean myocardial microbubble transit rates were measured from time-intensity plots derived from off-line analysis of MCE images obtained during the injection of microbubbles. An excellent correlation was noted between flow (measured with an extracorporeal electromagnetic flow probe) and mean myocardial RBC transit rate (y = 2.83 x 10(-3)x + 0.01, r = .96, SEE = 0.02, P < .001). A close correlation was also noted between mean RBC and microbubble myocardial transit rates (y = 1.01x + 0.01, r = .89, SEE = 0.02, P < .001). Despite its theoretical advantages, a lagged normal density function did not provide a better fit to the MCE data than the gamma-variate function.(ABSTRACT TRUNCATED AT 250 WORDS)

[1]  S. Kaul,et al.  An association between collateral blood flow and myocardial viability in patients with recent myocardial infarction. , 1992, The New England journal of medicine.

[2]  S. Kaul,et al.  Functional Significance of Collateral Blood Flow in Patients With Recent Acute Myocardial Infarction: A Study Using Myocardial Contrast Echocardiography , 1992, Circulation.

[3]  A Zeiher,et al.  Digital angiographic impulse response analysis of regional myocardial perfusion. Estimation of coronary flow, flow reserve, and distribution volume by compartmental transit time measurement in a canine model. , 1991, Circulation research.

[4]  W. Spotnitz,et al.  Intraoperative assessment of regional myocardial perfusion using quantitative myocardial contrast echocardiography: an experimental evaluation. , 1990, Journal of the American College of Cardiology.

[5]  J R Shapiro,et al.  Myocardial perfusion imaging by contrast echocardiography with use of intracoronary sonicated albumin in humans. , 1989, Journal of the American College of Cardiology.

[6]  J. Bassingthwaighte,et al.  Fractal Nature of Regional Myocardial Blood Flow Heterogeneity , 1989, Circulation research.

[7]  S S Segal,et al.  The behavior of sonicated albumin microbubbles within the microcirculation: a basis for their use during myocardial contrast echocardiography. , 1989, Circulation research.

[8]  D D Watson,et al.  Assessment of Regional Myocardial Blood Flow with Myocardial Contrast Two-dimensional Echocardiography , 1989, Journal of the American College of Cardiology.

[9]  D. Ruppert,et al.  Transformation and Weighting in Regression , 1988 .

[10]  A. Weyman,et al.  Effects of selectively altering collateral driving pressure on regional perfusion and function in occluded coronary bed in the dog. , 1987, Circulation research.

[11]  A. Weyman,et al.  The importance of defining left ventricular area at risk in vivo during acute myocardial infarction: an experimental evaluation with myocardial contrast two-dimensional echocardiography. , 1987, Circulation.

[12]  G M Pohost,et al.  Contrast echocardiography in acute myocardial ischemia: I. In vivo determination of total left ventricular "area at risk". , 1984, Journal of the American College of Cardiology.

[13]  R. Kloner,et al.  Hydrogen peroxide contrast--enhanced two-dimensional echocardiography: real-time in vivo delineation of regional myocardial perfusion. , 1983, Circulation.

[14]  E. G. Tickner,et al.  Assessment of Myocardial Perfusion Abnormalities with Contrast‐enhanced Two‐dimensional Echocardiography , 1982, Circulation.

[15]  E H Wood,et al.  Applications of the Lagged Normal Density Curve as a Model for Arterial Dilution Curves , 1966, Circulation research.

[16]  C. Starmer,et al.  Indicator Transit Time Considered as a Gamma Variate , 1964, Circulation research.

[17]  P. Broadhurst,et al.  Clinical validation of a miniature nuclear probe system for continuous on-line monitoring of cardiac function and ST-segment. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[18]  S. Kaul,et al.  Albunex: a safe and effective commercially produced agent for myocardial contrast echocardiography. , 1989, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[19]  W. Rosenblum Ratio of red cell velocities near the vessel wall to velocities at the vessel center in cerebral microcirculation, and an apparent effect of blood viscosity on this ratio. , 1972, Microvascular research.

[20]  H. Goldsmith The flow of model particles and blood cells and its relation to thrombogenesis. , 1972, Progress in hemostasis and thrombosis.