Flux-Weakening Control of Nonsalient Pole PMSM Having Large Winding Inductance, Accounting for Resistive Voltage Drop and Inverter Nonlinearities

This paper proposes an improved flux-weakening control method to improve the drive performance of nonsalient pole permanent magnet synchronous motors having large winding inductance and consequently an infinite constant power speed ratio. The proposed method consists of two parts. The first part utilizes the voltage differences between the input and output of a minimum-magnitude-error over-modulation block to modify the d-axis current references. The second part uses the compensated q-axis voltage, in which the resistive voltage drop and the distorted voltage due to inverter nonlinearities are taken into account, to detect the maximum torque per voltage (MTPV) line. Under the MTPV condition, a PI controller with a low-pass filter is presented to modify the q-axis current reference. With these two parts, the bus voltage utilization in the proposed method is close to the six-step operation and the actual current trajectory approaches the ideal MTPV line. As a result, the drive performance in the whole flux-weakening region is optimized in terms of maximizing the output torque/power. The method also shows a good performance in transient response. Effectiveness and superiorities of the proposed method are verified by experimental results.

[1]  Hyun-Soo Kim,et al.  Nonlinearity estimation and compensation of PWM VSI for PMSM under resistance and flux linkage uncertainty , 2006, IEEE Transactions on Control Systems Technology.

[2]  Seung-Ki Sul,et al.  Inverter output voltage synthesis using novel dead time compensation , 1996 .

[3]  Thomas A. Lipo,et al.  On-line dead-time compensation technique for open-loop PWM-VSI drives , 1999 .

[4]  T.J.E. Miller,et al.  Field-weakening performance of brushless synchronous AC motor drives , 1994 .

[5]  D. Howe,et al.  Analysis of a Novel Multi-Tooth Flux-Switching PM Brushless AC Machine for High Torque Direct-Drive Applications , 2008, IEEE Transactions on Magnetics.

[6]  S. Hiti,et al.  Two improved flux weakening schemes for surface mounted permanent magnet synchronous machine drives employing space vector modulation , 1998, IECON '98. Proceedings of the 24th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.98CH36200).

[7]  Seung-Ki Sul,et al.  A novel flux weakening algorithm for surface mounted permanent magnet synchronous machines with infinite constant power speed ratio , 2007, 2007 International Conference on Electrical Machines and Systems (ICEMS).

[8]  D. Howe,et al.  Online optimal flux-weakening control of permanent-magnet brushless AC drives , 2000 .

[9]  S. Sul,et al.  Novel Antiwindup of a Current Regulator of a Surface-Mounted Permanent-Magnet Motor for Flux-Weakening Control , 2005, IEEE Transactions on Industry Applications.

[10]  S. Sul,et al.  A new robust SPMSM control to parameter variations in flux weakening region , 1996, Proceedings of the 1996 IEEE IECON. 22nd International Conference on Industrial Electronics, Control, and Instrumentation.

[11]  K. Al-Haddad,et al.  A Modeling Technique to Analyze the Impact of Inverter Supply Voltage and Cable Length on Industrial Motor-Drives , 2008, IEEE Transactions on Power Electronics.

[12]  Juri Jatskevich,et al.  High-Frequency Modeling of the Long-Cable-Fed Induction Motor Drive System Using TLM Approach for Predicting Overvoltage Transients , 2010, IEEE Transactions on Power Electronics.

[13]  Q.M.J. Wu,et al.  An accurate approach of nonlinearity compensation for VSI inverter output voltage , 2004, IEEE Transactions on Power Electronics.

[14]  Chan-Hee Choi,et al.  Inverter Nonlinearity Compensation in the Presence of Current Measurement Errors and Switching Device Parameter Uncertainties , 2007, IEEE Transactions on Power Electronics.

[15]  Seung-Ki Sul,et al.  New flux weakening control for surface mounted permanent magnet synchronous machine using gradient descent method , 2007, 2007 7th Internatonal Conference on Power Electronics.

[16]  Timothy J. E. Miller,et al.  Theoretical limitations to the field-weakening performance of the five classes of brushless synchronous AC motor drive , 1993 .

[17]  D. Howe,et al.  Influence of inaccuracies in machine parameters on field-weakening performance of PM brushless AC drives , 1999, IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272).

[18]  Roberto Petrella,et al.  Feedforward Flux-Weakening Control of Surface-Mounted Permanent-Magnet Synchronous Motors Accounting for Resistive Voltage Drop , 2010, IEEE Transactions on Industrial Electronics.

[19]  V. G. Agelidis,et al.  A high-performance vector controlled interior PM synchronous motor drive with extended speed range capability , 2001, IECON'01. 27th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.37243).

[20]  Jiunn-Jiang Chen,et al.  Minimum copper loss flux-weakening control of surface mounted permanent magnet synchronous motors , 2003 .

[21]  D.B. Rutledge,et al.  Two flux weakening schemes for surface-mounted permanent-magnet synchronous drives. Design and transient response considerations , 1999, ISIE '99. Proceedings of the IEEE International Symposium on Industrial Electronics (Cat. No.99TH8465).

[22]  S. Morimoto,et al.  Expansion of operating limits for permanent magnet motor by current vector control considering inverter capacity , 1990 .

[23]  Ned Mohan,et al.  Analysis of current-regulated voltage-source inverters for permanent magnet synchronous motor drives in normal and extended speed ranges , 1990 .

[24]  Tae-Suk Kwon,et al.  Novel anti-windup of a current regulator of a surface-mounted permanent-magnet motor for flux-weakening control , 2005 .

[25]  Ching-Tsai Pan,et al.  A robust field-weakening control strategy for surface-mounted permanent-magnet motor drives , 2005 .

[26]  D. Howe,et al.  Influence of winding resistance on flux-weakening performance of a permanent magnet brushless AC drive , 2002 .