Regenerative microchannel electrode array for peripheral nerve interfacing

A regenerative microchannel scaffold capable of housing microelectrodes to form a high-throughput peripheral nerve interface is described. The regenerative microchannel scaffold was fabricated using polydimethylsiloxane (PDMS) and SU-8 as substrate and structural materials, respectively. This microchannel scaffold is capable of being integrated with a PDMS-based thin-film microelectrode array (MEA) to form a peripheral nerve interface. Preliminary in vitro characterization was performed using dorsal root ganglia cultures to evaluate biocompatibility and the ability of the microchannel design to direct and orient neurite outgrowth. Our findings provided evidence that the microchannel design will be effective in directing axon regeneration to the benefit of a neural interfacing device.

[1]  Stephen P. DeWeerth,et al.  A conformable microelectrode array (cMEA) with integrated electronics for peripheral nerve interfacing , 2010, 2010 Biomedical Circuits and Systems Conference (BioCAS).

[2]  M. A. Johnson,et al.  Chronic recording of regenerating VIIIth nerve axons with a sieve electrode. , 2000, Journal of neurophysiology.

[3]  Stéphanie P. Lacour,et al.  Microchannels as Axonal Amplifiers , 2008, IEEE Transactions on Biomedical Engineering.

[4]  K. Horch,et al.  Residual function in peripheral nerve stumps of amputees: implications for neural control of artificial limbs. , 2004, The Journal of hand surgery.

[5]  R. Butera,et al.  Unmyelinated Aplysia Nerves Exhibit a Nonmonotonic Blocking Response to High-Frequency Stimulation , 2009, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[6]  Liang Guo,et al.  High‐Density Stretchable Electronics: Toward an Integrated Multilayer Composite , 2010, Advanced materials.

[7]  W. Marsden I and J , 2012 .

[8]  J. Young,et al.  The nodes of Ranvier , 1952, Proceedings of the Royal Society of London. Series B - Biological Sciences.

[9]  Stéphanie P. Lacour,et al.  Microchannel Electrodes for Recording and Stimulation: In Vitro Evaluation , 2009, IEEE Transactions on Biomedical Engineering.

[10]  Silvestro Micera,et al.  A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems , 2005, Journal of the peripheral nervous system : JPNS.

[11]  B. Haeffele,et al.  Conduction block induced by high frequency AC stimulation in unmyelinated nerves , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.