Temporal Constraints in Renal Perfusion Imaging With a 2-Compartment Model

Objective:To assess the required temporal resolution and total acquisition time for renal perfusion and filtration measurements with a 2-compartment model. Material and Methods:Saturation-recovery TurboFLASH perfusion measurements of 15 healthy volunteers were acquired at 1.5 T, with a temporal resolution of 1 second during the first pass and a total acquisition time of 270 seconds. The time courses were then regridded and truncated to yield new data sets with temporal resolutions from 1 to 30 seconds in 1-second increments and with total acquisition times from 30 to 270 seconds in 5-second increments, respectively. Each new dataset was postprocessed by fitting the time courses to a 2-compartment model producing measures of perfusion and filtration: plasma volume (PV), plasma flow (PF), tubular volume (TV), and tubular flow (TF). The effect of reducing the temporal resolution or the total acquisition time was investigated by comparing the model parameters with those obtained at full temporal resolution and acquisition time and quantified by defining a discretization error (DE) and a truncation error (TE), respectively. For each parameter, the required temporal resolution and total acquisition times were defined by demanding a DE and TE of less than 10%. Results:It can be concluded from the analysis of the DE and TE that the acquisition of the parameters PF and TF requires a temporal resolution of at least 4 and 5 seconds, respectively. For the other 2 parameters, a temporal resolution of at least 9 seconds is sufficient. The required total acquisition times for PF and PV were 35 and 85 seconds, whereas for the parameters TF and TV, 230 and 255 seconds, respectively, are required. Conclusion:Renal perfusion measurements should be acquired with a temporal resolution of at least 4 seconds. To evaluate the renal excretory function adequately, the total acquisition time should be at least 255 seconds.

[1]  Nicolas Grenier,et al.  Update of renal imaging. , 2006, Seminars in nuclear medicine.

[2]  David L Buckley,et al.  Measurement of single kidney function using dynamic contrast‐enhanced MRI: Comparison of two models in human subjects , 2006, Journal of magnetic resonance imaging : JMRI.

[3]  F. Schick,et al.  Relaxivity of Gadopentetate Dimeglumine (Magnevist), Gadobutrol (Gadovist), and Gadobenate Dimeglumine (MultiHance) in Human Blood Plasma at 0.2, 1.5, and 3 Tesla , 2006, Investigative radiology.

[4]  Maximilian F Reiser,et al.  MRI-Measurement of Perfusion and Glomerular Filtration in the Human Kidney With a Separable Compartment Model , 2008, Investigative radiology.

[5]  R Luypaert,et al.  Quantification of renal perfusion and function on a voxel‐by‐voxel basis: A feasibility study , 2005, Magnetic resonance in medicine.

[6]  Henry Rusinek,et al.  Dynamic three-dimensional MR renography for the measurement of single kidney function: initial experience. , 2003, Radiology.

[7]  J. Mintorovitch,et al.  Comparison of Magnetic Properties of MRI Contrast Media Solutions at Different Magnetic Field Strengths , 2005, Investigative radiology.

[8]  H Rusinek,et al.  MR renography with low-dose gadopentetate dimeglumine: feasibility. , 2001, Radiology.

[9]  Jacques Belenger,et al.  Noninvasive Measurement of Absolute Renal Perfusion by Contrast Medium-Enhanced Magnetic Resonance Imaging , 2003, Investigative radiology.

[10]  Michael Bock,et al.  Quantification of renal perfusion using an intravascular contrast agent (part 1): Results in a canine model , 2003, Magnetic resonance in medicine.

[11]  J Paul Finn,et al.  Renal perfusion: Comparison of saturation‐recovery TurboFLASH measurements at 1.5T with saturation‐recovery TurboFLASH and time‐resolved echo‐shared angiographic technique (TREAT) at 3.0T , 2006, Journal of magnetic resonance imaging : JMRI.

[12]  N. Michoux,et al.  Analysis of contrast-enhanced MR images to assess renal function , 2006, Magnetic Resonance Materials in Physics, Biology and Medicine.

[13]  Laurent Hermoye,et al.  Glomerular filtration rate: Assessment with dynamic contrast‐enhanced MRI and a cortical‐compartment model in the rabbit kidney , 2004, Journal of magnetic resonance imaging : JMRI.

[14]  H. Teh,et al.  MR renography using a dynamic gradient-echo sequence and low-dose gadopentetate dimeglumine as an alternative to radionuclide renography. , 2003, AJR. American journal of roentgenology.

[15]  F. Schick,et al.  Dynamic Magnetic Resonance Nephrography: Is Saturation Recovery TrueFISP Advantageous Over Saturation Recovery TurboFLASH? , 2007, Investigative radiology.

[16]  W. Rau,et al.  Measurement of single‐kidney glomerular filtration rate using a contrast‐enhanced dynamic gradient‐echo sequence and the Rutland‐Patlak plot technique , 2003, Journal of magnetic resonance imaging : JMRI.

[17]  M. Bock,et al.  Quantification of renal perfusion abnormalities using an intravascular contrast agent (part 2): Results in animals and humans with renal artery stenosis , 2003, Magnetic resonance in medicine.

[18]  F. Terrier,et al.  Parametric and quantitative analysis of MR renographic curves for assessing the functional behaviour of the kidney. , 2005, European journal of radiology.

[19]  W. Rohrschneider,et al.  MR to assess renal function in children , 2003, European Radiology.

[20]  Maximilian F Reiser,et al.  Intraindividual Comparison of MR-Renal Perfusion Imaging at 1.5 T and 3.0 T , 2007, Investigative radiology.

[21]  N. Oesingmann,et al.  Functional renal imaging: nonvascular renal disease , 2007, Abdominal Imaging.

[22]  M. Knopp,et al.  Estimating kinetic parameters from dynamic contrast‐enhanced t1‐weighted MRI of a diffusable tracer: Standardized quantities and symbols , 1999, Journal of magnetic resonance imaging : JMRI.

[23]  S. Sourbron,et al.  Deconvolution of dynamic contrast‐enhanced MRI data by linear inversion: Choice of the regularization parameter , 2004, Magnetic resonance in medicine.

[24]  Maximilian F Reiser,et al.  Renal artery stenosis: functional assessment with dynamic MR perfusion measurements--feasibility study. , 2006, Radiology.