Mechanical induction of critically delayed bone healing in sheep: radiological and biomechanical results.

This study aimed to mechanically produce a standardized ovine model for a critically delayed bone union. A tibial osteotomy was stabilized with either a rigid (group I) or mechanically critical (group II) external fixator in sheep. Interfragmentary movements and ground reaction forces were monitored throughout the healing period of 9 weeks. After sacrifice at 6 weeks, 9 weeks and 6 months, radiographs were taken and the tibiae were examined mechanically. Interfragmentary movements were considerably larger in group II throughout the healing period. Unlike group I, the operated limb in group II did not return to full weight bearing during the treatment period. Radiographic and mechanical observations showed significantly inferior bone healing in group II at 6 and 9 weeks compared to group I. After 6 months, five sheep treated with the critical fixator showed radiological bridging of the osteotomy, but the biomechanical strength of the repair was still inferior to group I at 9 weeks. The remaining three animals had even developed a hypertrophic non-union. In this study, mechanical instability was employed to induce a critically delayed healing model in sheep. In some cases, this approach even led to the development of a hypertrophic non-union. The mechanical induction of critical bone healing using an external fixation device is a reasonable attempt to investigate the patho-physiological healing cascade without suffering from any biological intervention. Therefore, the presented ovine model provides the basis for a comparative evaluation of mechanisms controlling delayed and standard bone healing.

[1]  D. Rosenbaum,et al.  Plantar pressure distribution measurements. Technical background and clinical applications , 1997 .

[2]  E. Rodríguez‐Merchán,et al.  Nonunion: general principles and experimental data. , 2004, Clinical orthopaedics and related research.

[3]  D Kaspar,et al.  Effects of Mechanical Factors on the Fracture Healing Process , 1998, Clinical orthopaedics and related research.

[4]  N P Haas,et al.  Angle stable locking reduces interfragmentary movements and promotes healing after unreamed nailing. Study of a displaced osteotomy model in sheep tibiae. , 2005, The Journal of bone and joint surgery. American volume.

[5]  D. Hu,et al.  Molecular aspects of healing in stabilized and non‐stabilized fractures , 2001, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[6]  David J Hak,et al.  Development of an atrophic nonunion model and comparison to a closed healing fracture in rat femur , 2003, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[7]  G N Duda,et al.  The course of bone healing is influenced by the initial shear fixation stability , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[8]  M. Schaffler,et al.  Prevention of fracture healing in rats by an inhibitor of angiogenesis. , 2001, Bone.

[9]  G. Bergmann,et al.  Musculo-skeletal loading conditions at the hip during walking and stair climbing. , 2001, Journal of biomechanics.

[10]  J Kenwright,et al.  The role of fixator frame stiffness in the control of fracture healing. An experimental study. , 1993, Journal of biomechanics.

[11]  HighWire Press,et al.  The journal of bone and joint surgery - British volume , 1948 .

[12]  E R Draper,et al.  The effect of devascularisation upon early bone healing in dynamic external fixation. , 1991, The Journal of bone and joint surgery. British volume.

[13]  L. Bilston,et al.  Optimal Timing of a Single Dose of Zoledronic Acid to Increase Strength in Rat Fracture Repair , 2007, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[14]  W. Taylor,et al.  Gait evaluation: a tool to monitor bone healing? , 2005, Clinical biomechanics.

[15]  J. Peltonen,et al.  An experimental model for non-union in rats. , 1995, Injury.

[16]  Georg N. Duda,et al.  Bewertung der Stabilität von Frakturfixationssystemen: Mechanische Vorrichtung zur Untersuchung der 3-D-Steifigkeit in vitro - Assessment of the Stability of Fracture Fixation Systems: Mechanical Device to Investigate the 3-D Stiffness in vitro , 2001 .

[17]  L Claes,et al.  [Mechanical modification of callus healing]. , 2000, Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen.

[18]  K. Stürmer,et al.  [New aspects of closed intramedullary nailing and marrow cavity reaming in animal experiments. I. The tibia of the sheep, as a model for intramedullar nailing (author's transl)]. , 1980, Unfallheilkunde.

[19]  Georg N. Duda,et al.  Does partial weight bearing unload a healing bone in external ring fixation? , 2003, Langenbeck's Archives of Surgery.

[20]  K. Loeffler,et al.  Vergleich der histologischen Struktur der Kompakta der langen Röhren‐knochen bei Maus, Hamster, Ratte, Meerschweinchen, Kaninchen, Katze und Hund während der Altersentwicklung , 1997 .

[21]  N. Haas Callusmodulation – Fiktion oder Realität? , 2000, Der Chirurg.

[22]  Geert Carmeliet,et al.  Placental growth factor mediates mesenchymal cell development, cartilage turnover, and bone remodeling during fracture repair. , 2006, The Journal of clinical investigation.

[23]  O. Oni A non-union model of the rabbit tibial diaphysis. , 1995, Injury.

[24]  Allen E. Goodship,et al.  Controlled Induction of a Pseudarthrosis: A Study Using a Rodent Model , 2003, Journal of orthopaedic trauma.

[25]  M O Heller,et al.  Comparison of unreamed nailing and external fixation of tibial diastases—mechanical conditions during healing and biological outcome , 2004, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[26]  J. B. Volpon Nonunion using a canine model , 2004, Archives of Orthopaedic and Trauma Surgery.