Effects of balanced and unbalanced voltage sags on DC adjustable-speed drives

This paper analyzes the sensitivity of DC adjustable-speed drives to balanced and unbalanced voltage sags. The influence of sag type, depth, duration and phase-angle jump on DC drives is studied. The control of the DC drive has been taken into account to understand drive behavior in the presence of voltage sags. Two working modes of the DC motor are considered in the study: as a consumer load and as a regenerative load. When the DC motor works as a consumer load, the study shows that sag type and depth have a significant influence on drive behavior. However, the voltage sag can be ridden through if the rectifier firing angle is set correctly by the control. When the DC motor works as a regenerative load, the study shows the consequences of the three-phase rectifier commutation failure due to the voltage sag.

[1]  E.K.K. Sng,et al.  A novel solution to restore a three-phase thyristor inverter from commutation failure due to voltage dip , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[2]  R.A.A. de Graaff,et al.  Behavior of AC and DC drives during voltage sags with phase-angle jump and three-phase unbalance , 1999, IEEE Power Engineering Society. 1999 Winter Meeting (Cat. No.99CH36233).

[3]  N. S. Tunaboylu,et al.  Ride-through issues for DC motor drives during voltage sags , 1995, Proceedings IEEE Southeastcon '95. Visualize the Future.

[4]  Jos Arrillaga,et al.  Analysis of the AC Voltage Distortion produced by Converter-Fed DC Drives , 1985, IEEE Transactions on Industry Applications.

[5]  Math Bollen Characterisation of voltage sags experienced by three-phase adjustable-speed drives , 1997 .

[6]  M. H. J. Bollen Voltage Recovery after Unbalanced and Balanced Voltage Dip in Three-Phase Systems , 2002, IEEE Power Engineering Review.

[7]  E.K.K. Sng,et al.  Study of line-commutated thyristor inverter under voltage dips and novel ride-through solution , 2004, The 4th International Power Electronics and Motion Control Conference, 2004. IPEMC 2004..

[8]  Math Bollen,et al.  Understanding Power Quality Problems: Voltage Sags and Interruptions , 1999 .

[9]  M. Steurer,et al.  A novel approach to power quality assessment: real time hardware-in-the-loop test bed , 2005, IEEE Transactions on Power Delivery.

[10]  M. Grotzbach,et al.  Investigation of AC/DC converter harmonics by an analytical based time-discrete approach , 1997 .

[11]  A. Mansoor,et al.  Effects of voltage sags on AC motor drives , 1997, 1997 IEEE Annual Textile, Fiber and Film Industry Technical Conference.