Pulsatile Pediatric Ventricular Assist Devices

A pulsatile pediatric ventricular assist device (PVAD) is being developed at The Pennsylvania State University to provide mechanical circulatory support in infants and children. The PVAD is based on the design of the adult-sized Pierce-Donachy VAD (Thoratec VAD). The infant-sized PVAD has a dynamic stroke volume of approximately 13 ml. A larger 25-ml size for children is also planned. The stroke volumes, beat rates, and pulsatility are comparable to normal physiologic values. The expected maximum duration of use is 6 months. The PVAD is intended to be placed paracorporeally, although the pump may be implanted for bridge-to-transplant applications. The pneumatically actuated PVAD uses a full-to-empty control mode, which allows maximum flexibility in its application for left, right, or biventricular assistance. The device may be used with atrial or ventricular inlet cannulation, with blood return to the aorta or pulmonary artery. In vitro testing is underway to measure hydrodynamic performance, hemolysis, and flow velocities using particle image velocimetry. In vivo implantation studies will be performed in juvenile goats or sheep after the completion of baseline studies to assess hematology and surgical fit.

[1]  R. Marchant,et al.  Shear-dependent changes in the three-dimensional structure of human von Willebrand factor. , 1996, Blood.

[2]  C. Zapanta,et al.  Effect of the Diastolic and Systolic Duration on Valve Cavitation in a Pediatric Pulsatile Ventricular Assist Device , 2005, ASAIO journal.

[3]  E. R. Benton On the flow due to a rotating disk , 1966, Journal of Fluid Mechanics.

[4]  P. D. del Nido,et al.  Mechanical circulatory support in children with cardiac disease. , 1999, The Journal of thoracic and cardiovascular surgery.

[5]  H. Gulbins,et al.  Mechanical Circulatory Support in Pediatric Patients with the MEDOS Assist Device , 2005, ASAIO journal.

[6]  E. Vogler,et al.  Procoagulant stimulus processing by the intrinsic pathway of blood plasma coagulation. , 2005, Biomaterials.

[7]  G Rosenberg,et al.  In vivo observation of cavitation on prosthetic heart valves. , 1996, ASAIO journal.

[8]  G. Rosenberg,et al.  Postoperative cardiac support with a pulsatile assist pump: techniques and results. , 1987, Artificial organs.

[9]  Steven Deutsch,et al.  Viscoelasticity of Pediatric Blood and its Implications for the Testing of a Pulsatile Pediatric Blood Pump , 2005, ASAIO journal.

[10]  W S Pierce,et al.  Pierce-Donachy pediatric VAD: progress in development. , 1996, The Annals of thoracic surgery.

[11]  D. Farrar,et al.  Current Clinical Status of Pulsatile Pediatric Circulatory Support , 2002, ASAIO journal.

[12]  D. Farrar,et al.  Thoratec Ventricular Assist Devices in Pediatric Patients: Update on Clinical Results , 2005, ASAIO journal.

[13]  G Rosenberg,et al.  Fluid dynamics of a pediatric ventricular assist device. , 2000, Artificial organs.

[14]  H. Netz,et al.  Ventricular assist devices in pediatrics , 2001, Images in paediatric cardiology.

[15]  M. Turina,et al.  Improved Biocompatibility of Heparin Surface-Coated Ventricular Assist Devices , 1992, The International journal of artificial organs.

[16]  D B Geselowitz,et al.  LDA measurements of mean velocity and Reynolds stress fields within an artificial heart ventricle. , 1994, Journal of biomechanical engineering.

[17]  M. Shive,et al.  Shear stress and material surface effects on adherent human monocyte apoptosis. , 2002, Journal of biomedical materials research.

[18]  W. Weiss,et al.  The effect of pump rate and filling on hemolysis in a pulsatile left ventricular assist device (LVAD) , 2002, Proceedings of the IEEE 28th Annual Northeast Bioengineering Conference (IEEE Cat. No.02CH37342).

[19]  Paul E. Allaire,et al.  Pediatric Circulatory Support Systems , 2002, ASAIO journal.