Fast high-resolution micro-CT with exact reconstruction methods

We have constructed a helical trajectory X-ray micro-CT system which enables high-resolution tomography within practical acquisition times. In the quest for ever-increasing resolution, lab-based X-ray micro-CT systems are limited by the spot size of the X-ray source. Unfortunately, decreasing the spot size reduces the X-ray flux, and therefore the signal-to-noise ratio (SNR). The reduced source flux can be offset by moving the detector closer to the source, thereby capturing a larger solid angle of the X-ray beam. We employ a helical scanning trajectory, accompanied by an exact reconstruction method to avoid the artifacts resulting from the use of large cone-angles with circular trajectories. In this paper, we present some challenges which arise when adopting this approach in a high-resolution cone-beam micro-CT system.

[1]  Ge Wang,et al.  Filtered backprojection formula for exact image reconstruction from cone-beam data along a general scanning curve. , 2004, Medical physics.

[2]  Rolf Clackdoyle,et al.  A cone-beam reconstruction algorithm using shift-variant filtering and cone-beam backprojection , 1994, IEEE Trans. Medical Imaging.

[3]  Cisheng Zhang,et al.  Tilted plane Feldkamp type reconstruction algorithm for spiral cone-beam CT , 2004 .

[4]  Tim Sawkins,et al.  X-ray tomography for mesoscale physics applications , 2004 .

[5]  Pierre Grangeat Analyse d'un systeme d'imagerie 3d par reconstruction a partir de radiographies x en geometrie conique , 1987 .

[6]  C Axelsson,et al.  Three-dimensional reconstruction from cone-beam data in O(N3 log N) time. , 1994, Physics in medicine and biology.

[7]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[8]  H. Tuy AN INVERSION FORMULA FOR CONE-BEAM RECONSTRUCTION* , 1983 .

[9]  A. Katsevich,et al.  Exact filtered backprojection reconstruction for dynamic pitch helical cone beam computed tomography. , 2004, Physics in medicine and biology.

[10]  Ming Jiang,et al.  Parallel Implementation of Katsevich's FBP Algorithm , 2006, Int. J. Biomed. Imaging.

[11]  Jun Ni,et al.  A Parallel Implementation of the Katsevich Algorithm for 3-D CT Image Reconstruction , 2006, The Journal of Supercomputing.

[12]  A. Katsevich Analysis of an exact inversion algorithm for spiral cone-beam CT. , 2002, Physics in medicine and biology.

[13]  Alexander Katsevich,et al.  Theoretically Exact Filtered Backprojection-Type Inversion Algorithm for Spiral CT , 2002, SIAM J. Appl. Math..

[14]  Xiaochuan Pan,et al.  Image reconstruction on PI-lines by use of filtered backprojection in helical cone-beam CT. , 2004, Physics in medicine and biology.

[15]  J. Hsieh,et al.  A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT—helical scanning , 2006, Physics in medicine and biology.

[16]  Andrew Kingston,et al.  An auto-focus method for generating sharp 3D tomographic images , 2010, Optical Engineering + Applications.

[17]  Alexander Sasov,et al.  Compensation of mechanical inaccuracies in micro-CT and nano-CT , 2008, Optical Engineering + Applications.

[18]  Hengyong Yu,et al.  A unified framework for exact cone-beam reconstruction formulas. , 2005, Medical physics.

[19]  Hsien-Hsin S. Lee,et al.  Optimizing Katsevich image reconstruction algorithm on multicore processors , 2007, 2007 International Conference on Parallel and Distributed Systems.

[20]  M. Colbert,et al.  Applications of high-resolution X-ray computed tomography in petrology, meteoritics and palaeontology , 2003, Geological Society, London, Special Publications.

[21]  Xiaochuan Pan,et al.  Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT. , 2004, Physics in medicine and biology.

[22]  Fei Yang,et al.  Fast Katsevich Algorithm Based on GPU for Helical Cone-Beam Computed Tomography , 2010, IEEE Transactions on Information Technology in Biomedicine.

[23]  G. Wang,et al.  A general cone-beam reconstruction algorithm , 1993, IEEE Trans. Medical Imaging.

[24]  Frédéric Noo,et al.  Exact helical reconstruction using native cone-beam geometries. , 2003, Physics in medicine and biology.