Research on Low Concentration Municipal Wastewater Removal Rate with Chemical-Biological Flocculation and Suspended Medium Process

In this paper, chemical and biological flocculation and suspended medium process was applied to treat low concentration municipal wastewater in a pilot scale test in order to find the optimum operational parameter. The results showed that: system on pollutant removal mainly on chemical and biological flocculation reaction pool, Under the optimal operating condition, CODCr, TP and SS removal efficiencies reached 75.5%, 76%and 90.5% respectively, and the CODCr, TP, SS concentrations of effluent meet the National Wastewater Integrated Discharge Standard. The optimum operating conditions according to the local actual situation, running for more than half a year, for the optimization of control parameters for the contrast obtained.

[1]  Zhang Wen-ming Analysis of dynamic property of a new type pylon in free-standing state , 2009 .

[3]  J. Koenderink Q… , 2014, Les noms officiels des communes de Wallonie, de Bruxelles-Capitale et de la communaute germanophone.