Accurately Monitoring the Depth of Anaesthesia Using an Intelligent Method

This paper introduces the development of a monitoring system to depth of anaesthesia in a surgery. We first developed the audiory evoked potential (AEP) method and the bispectrium method. Then we combined them together using a off-line trained neural networks. The preliminary results show that our calculated index is closely relative to the depth of anaesthesia.

[1]  G D Puri,et al.  Paradoxical changes in bispectral index during nitrous oxide administration. , 2001, British journal of anaesthesia.

[2]  P. Sebel,et al.  Prediction of Movement Using Bispectral Electroencephalographic Analysis During Propofol/Alfentanil or Isoflurane/Alfentanil Anesthesia , 1995, Anesthesia and analgesia.

[3]  G N Kenny,et al.  Auditory evoked potential index: a quantitative measure of changes in auditory evoked potentials during general anaesthesia , 1997, Anaesthesia.

[4]  P. Sebel,et al.  Evoked potentials during isoflurane anaesthesia. , 1987, British journal of anaesthesia.

[5]  K L Posner,et al.  Awareness during anesthesia: a closed claims analysis. , 1999, Anesthesiology.

[6]  Nassib G. Chamoun,et al.  An introduction to bispectral analysis for the electroencephalogram , 1994, Journal of Clinical Monitoring.

[7]  M Renna,et al.  Bispectral index and anaesthesia in the elderly. , 2000, Minerva anestesiologica.

[8]  C Thornton,et al.  Evoked responses in anaesthesia. , 1998, British journal of anaesthesia.

[9]  P. Booker,et al.  Monitoring depth of anaesthesia by EEG , 2003 .

[10]  Piotr J. Durka,et al.  Single evoked potential reconstruction by means of wavelet transform , 2004, Biological Cybernetics.

[11]  Jin Liu,et al.  Electroencephalographic Bispectral Index Correlates with Intraoperative Recall and Depth of Propofol-Induced Sedation , 1997, Anesthesia and analgesia.

[12]  C. Thornton,et al.  The auditory evoked response: a measure of depth of anaesthesia , 1989 .

[13]  J. Bruhn,et al.  Depth of anaesthesia monitoring: what's available, what's validated and what's next? , 2006, British journal of anaesthesia.

[14]  I. Rampil A Primer for EEG Signal Processing in Anesthesia , 1998, Anesthesiology.

[15]  C. Thomsen,et al.  Quantitative EEG in assessment of anaesthetic depth: comparative study of methodology. , 1996, British journal of anaesthesia.

[16]  T. Sloan,et al.  Evoked potential monitoring. , 1996, International anesthesiology clinics.

[17]  Peter S. Sebel,et al.  Bispectral Index Monitoring Allows Faster Emergence and Improved Recovery from Propofol, Alfentanil, and Nitrous Oxide Anesthesia , 1997 .

[18]  S. Henneberg,et al.  Autoregressive Modeling with Exogenous Input of Middle-Latency Auditory-Evoked Potentials to Measure Rapid Changes in Depth of Anesthesia , 1996, Methods of Information in Medicine.

[19]  Haralambos Mantzaridis,et al.  Comparison of Bispectral EEG Analysis and Auditory Evoked Potentials for Monitoring Depth Of Anaesthesia During Propofol Anaesthesia , 2000 .

[20]  G Schneider,et al.  Monitoring depth of anaesthesia. , 1997, European journal of anaesthesiology. Supplement.