Morphotype-Dependent Flow Characteristics in Bicuspid Aortic Valve Ascending Aortas: A Benchtop Particle Image Velocimetry Study

The bicuspid aortic valve (BAV) is a major risk factor for secondary aortopathy such as aortic dilation. The heterogeneous BAV morphotypes [left-right-coronary cusp fusion (LR), right-non-coronary cusp fusion (RN), and left-non-coronary cusp fusion (LN)] are associated with different dilation patterns, suggesting a role for hemodynamics in BAV aortopathogenesis. However, assessment of this theory is still hampered by the limited knowledge of the hemodynamic abnormalities generated by the distinct BAV morphotypes. The objective of this study was to compare experimentally the hemodynamics of a normal (i.e., non-dilated) ascending aorta (AA) subjected to tricuspid aortic valve (TAV), LR-BAV, RN-BAV, and NL-BAV flow. Tissue BAVs reconstructed from porcine TAVs were subjected to physiologic pulsatile flow conditions in a left-heart simulator featuring a realistic aortic root and compliant aorta. Phase-locked particle image velocimetry experiments were carried out to characterize the flow in the aortic root and in the tubular AA in terms of jet skewness and displacement, as well as mean velocity, viscous shear stress and Reynolds shear stress fields. While all three BAVs generated skewed and asymmetrical orifice jets (up to 1.7- and 4.0-fold increase in flow angle and displacement, respectively, relative to the TAV at the sinotubular junction), the RN-BAV jet was out of the plane of observation. The LR- and NL-BAV exhibited a 71% increase in peak-systolic orifice jet velocity relative to the TAV, suggesting an inherent degree of stenosis in BAVs. While these two BAV morphotypes subjected the convexity of the aortic wall to viscous shear stress overloads (1.7-fold increase in maximum peak-systolic viscous shear stress relative to the TAV-AA), the affected sites were morphotype-dependent (LR-BAV: proximal AA, NL-BAV: distal AA). Lastly, the LR- and NL-BAV generated high degrees of turbulence in the AA (up to 2.3-fold increase in peak-systolic Reynolds shear stress relative to the TAV) that were sustained from peak systole throughout the deceleration phase. This in vitro study reveals substantial flow abnormalities (increased jet skewness, asymmetry, jet velocity, turbulence, and shear stress overloads) in non-dilated BAV aortas, which differ from those observed in dilated aortas but still coincide with aortic wall regions prone to dilation.

[1]  M. Thubrikar,et al.  The congenitally bicuspid aortic valve: how does it function? Why does it fail? , 2004, The Annals of thoracic surgery.

[2]  Michael Markl,et al.  Wall shear stress and flow patterns in the ascending aorta in patients with bicuspid aortic valves differ significantly from tricuspid aortic valves: a prospective study. , 2013, European heart journal cardiovascular Imaging.

[3]  Alberto Redaelli,et al.  Restricted cusp motion in right-left type of bicuspid aortic valves: a new risk marker for aortopathy. , 2012, The Journal of thoracic and cardiovascular surgery.

[4]  Ajit P. Yoganathan,et al.  Estimation of the Shear Stress on the Surface of an Aortic Valve Leaflet , 1999, Annals of Biomedical Engineering.

[5]  H. Sievers,et al.  A classification system for the bicuspid aortic valve from 304 surgical specimens. , 2007, The Journal of thoracic and cardiovascular surgery.

[6]  N. Rajamannan,et al.  Bicuspid aortic valve hemodynamics induces abnormal medial remodeling in the convexity of porcine ascending aortas , 2014, Biomechanics and Modeling in Mechanobiology.

[7]  F. Sotiropoulos,et al.  Comparative hemodynamics in an aorta with bicuspid and trileaflet valves , 2015 .

[8]  P. Sucosky Hemodynamic Mechanisms of Bicuspid Aortic Valve Calcification and Aortopathy , 2014 .

[9]  Samantha K. Atkins,et al.  Mechanobiology in Cardiovascular Disease Management: Potential Strategies and Current Needs , 2016, Front. Bioeng. Biotechnol..

[10]  J. Bavaria,et al.  Bicuspid aortic valves are associated with aortic dilatation out of proportion to coexistent valvular lesions. , 2000, Circulation.

[11]  D. Saloner,et al.  MRI hemodynamic markers of progressive bicuspid aortic valve‐related aortic disease , 2014, Journal of magnetic resonance imaging : JMRI.

[12]  W. Roberts,et al.  The congenitally bicuspid aortic valve. A study of 85 autopsy cases. , 1970, The American journal of cardiology.

[13]  A. Redaelli,et al.  Towards the improved quantification of in vivo abnormal wall shear stresses in BAV-affected patients from 4D-flow imaging: Benchmarking and application to real data. , 2017, Journal of biomechanics.

[14]  Richard S. Lee,et al.  The aortopathy of bicuspid aortic valve disease has distinctive patterns and usually involves the transverse aortic arch. , 2008, The Journal of thoracic and cardiovascular surgery.

[15]  M. Thubrikar,et al.  Patterns of calcific deposits in operatively excised stenotic or purely regurgitant aortic valves and their relation to mechanical stress. , 1986, The American journal of cardiology.

[16]  Michael Markl,et al.  Bicuspid Aortic Valve Is Associated With Altered Wall Shear Stress in the Ascending Aorta , 2012, Circulation. Cardiovascular imaging.

[17]  T. Kuntze,et al.  Correlation between systolic transvalvular flow and proximal aortic wall changes in bicuspid aortic valve stenosis. , 2014, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[18]  Nikolay V. Vasilyev,et al.  In Vitro Characterization of Bicuspid Aortic Valve Hemodynamics Using Particle Image Velocimetry , 2012, Annals of Biomedical Engineering.

[19]  D. Saloner,et al.  Comparison of four‐dimensional flow parameters for quantification of flow eccentricity in the ascending aorta , 2011, Journal of magnetic resonance imaging : JMRI.

[20]  Stefan Neubauer,et al.  Aortic Dilation in Bicuspid Aortic Valve Disease: Flow Pattern Is a Major Contributor and Differs With Valve Fusion Type , 2013, Circulation. Cardiovascular imaging.

[21]  A. Barker,et al.  Quantification of Hemodynamic Wall Shear Stress in Patients with Bicuspid Aortic Valve Using Phase-Contrast MRI , 2010, Annals of Biomedical Engineering.

[22]  Samantha K. Atkins,et al.  Etiology of bicuspid aortic valve disease: Focus on hemodynamics. , 2014, World journal of cardiology.

[23]  W. B. Nelson,et al.  Anatomic versus Effective Orifice Area in a Bicuspid Aortic Valve , 2014, Echocardiography.

[24]  Michael Markl,et al.  Bicuspid Aortic Cusp Fusion Morphology Alters Aortic Three-Dimensional Outflow Patterns, Wall Shear Stress, and Expression of Aortopathy , 2014, Circulation.

[25]  P. Sucosky,et al.  Effect of Bicuspid Aortic Valve Cusp Fusion on Aorta Wall Shear Stress: Preliminary Computational Assessment and Implication for Aortic Dilation , 2015 .

[26]  MRI-based Protocol to Characterize the Relationship Between Bicuspid Aortic Valve Morphology and Hemodynamics , 2015, Annals of Biomedical Engineering.

[27]  Samantha K. Atkins,et al.  Bicuspid aortic valve hemodynamics does not promote remodeling in porcine aortic wall concavity. , 2016, World journal of cardiology.

[28]  Janet Liu,et al.  Simulations of morphotype-dependent hemodynamics in non-dilated bicuspid aortic valve aortas. , 2017, Journal of biomechanics.

[29]  A. D. Corte The conundrum of aortic dissection in patients with bicuspid aortic valve: the tissue, the mechanics and the mathematics. , 2015 .

[30]  J. Edwards,et al.  The congenital bicuspid aortic valve. , 1961, Circulation.

[31]  Santanu Chandra,et al.  Computational assessment of bicuspid aortic valve wall-shear stress: implications for calcific aortic valve disease , 2012, Biomechanics and modeling in mechanobiology.

[32]  Michael Markl,et al.  The role of hemodynamics in bicuspid aortic valve disease. , 2011, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[33]  W. M. Swanson,et al.  Dimensions and Geometric Relationships of the Human Aortic Value as a Function of Pressure , 1974, Circulation research.

[34]  T. Kuntze,et al.  Is aortopathy in bicuspid aortic valve disease a congenital defect or a result of abnormal hemodynamics? A critical reappraisal of a one-sided argument. , 2011, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[35]  Clara Seaman,et al.  Steady flow hemodynamic and energy loss measurements in normal and simulated calcified tricuspid and bicuspid aortic valves. , 2014, Journal of biomechanical engineering.

[36]  N. Rajamannan,et al.  Bicuspid Aortic Valve Disease: From Bench to Bedside , 2013 .

[37]  C M Otto,et al.  The bicuspid aortic valve: an integrated phenotypic classification of leaflet morphology and aortic root shape , 2008, Heart.

[38]  A. Angelini,et al.  The morphology of the normal aortic valve as compared with the aortic valve having two leaflets. , 1989, The Journal of thoracic and cardiovascular surgery.

[39]  Michael D Hope,et al.  Images in cardiovascular medicine. Evaluation of bicuspid aortic valve and aortic coarctation with 4D flow magnetic resonance imaging. , 2008, Circulation.

[40]  A. Barker,et al.  Year in review: bicuspid aortopathy , 2016, Current opinion in cardiology.

[41]  W. Edwards,et al.  Congenitally bicuspid aortic valves: a surgical pathology study of 542 cases (1991 through 1996) and a literature review of 2,715 additional cases. , 1999, Mayo Clinic proceedings.

[42]  M. Alley,et al.  Bicuspid Aortic Valve : Four-dimensional MR Evaluation of Ascending Aortic Systolic Flow Patterns 1 , 2010 .

[43]  C. Ward Clinical significance of the bicuspid aortic valve , 2000, Heart.

[44]  Clara Seaman,et al.  Generation of Simulated Calcific Lesions in Valve Leaflets for Flow Studies. , 2015, The Journal of heart valve disease.

[45]  A. Yoganathan,et al.  The congenital bicuspid aortic valve can experience high-frequency unsteady shear stresses on its leaflet surface. , 2012, American journal of physiology. Heart and circulatory physiology.

[46]  Neelakantan Saikrishnan,et al.  The Congenital Bicuspid Aortic Valve can Experience High Frequency Unsteady Shear Stresses on its Leaflet Surface , 2012 .

[47]  Michael Markl,et al.  Characterization of Abnormal Wall Shear Stress Using 4D Flow MRI in Human Bicuspid Aortopathy , 2015, Annals of Biomedical Engineering.

[48]  Akihiko Ikeda,et al.  The Konno Procedure in Redo Aortic Valve Replacement after the Nicks Procedure. , 2015, The Journal of heart valve disease.