Signals selection of SVC device for damping oscillation
暂无分享,去创建一个
[1] Hartmut Logemann,et al. Multivariable feedback design : J. M. Maciejowski , 1991, Autom..
[2] K.Y. Lee,et al. Choice of FACTS device control inputs for damping interarea oscillations , 2004, IEEE Transactions on Power Systems.
[3] Joe H. Chow,et al. Concepts for design of FACTS controllers to damp power swings , 1995 .
[4] A. Kazemi,et al. FACTS devices in deregulated electric power systems: a review , 2004, 2004 IEEE International Conference on Electric Utility Deregulation, Restructuring and Power Technologies. Proceedings.
[5] Chun-Chang Liu,et al. An output feedback static var controller for the damping of generator oscillations , 1994 .
[6] Nadarajah Mithulananthan,et al. Comparison of PSS, SVC, and STATCOM controllers for damping power system oscillations , 2003 .
[7] Arturo Roman Messina,et al. An efficient placement algorithm of multiple controllers for damping power system oscillations , 1999, 1999 IEEE Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.99CH36364).
[8] Joe H. Chow,et al. Damping control design based on time-domain identified models , 1999 .
[9] J. Doyle,et al. Robust and optimal control , 1995, Proceedings of 35th IEEE Conference on Decision and Control.
[10] A. Feliachi,et al. Robust TCSC control design for damping inter-area oscillations , 2001, 2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262).
[11] B. Pal,et al. Robust Control in Power Systems , 2005 .
[12] N. Magaji,et al. Optimal location of FACTS devices for damping oscillations using residue factor , 2008, 2008 IEEE 2nd International Power and Energy Conference.
[13] Ian Postlethwaite,et al. Multivariable Feedback Control: Analysis and Design , 1996 .
[14] E. Z. Zhou,et al. Application of static VAr compensators to increase power system damping , 1993 .
[15] Marc M. J. van de Wal,et al. A review of methods for input/output selection , 2001, Autom..
[16] Pedro Ollero,et al. Controllability Analysis and Decentralized Control of a Wet Limestone Flue Gas Desulfurization Plant , 2008 .
[17] B. Chaudhuri,et al. Robust damping of multiple swing modes employing global stabilizing signals with a TCSC , 2004, IEEE Transactions on Power Systems.
[18] H. F. Wang,et al. Capability of the static VAr compensator in damping power system oscillations , 1996 .
[19] Saleh M. Bamasak,et al. Facts-based stabilizers for power system stability enhancement , 2005 .
[20] K.Y. Lee,et al. On selection of supplementary input signals for STATCOM to damp inter-area oscillations in power systems , 2005, IEEE Power Engineering Society General Meeting, 2005.
[21] Mohammed H. Haque. Damping improvement by FACTS devices: A comparison between STATCOM and SSSC , 2006 .
[22] Mohd Wazir Mustafa,et al. Optimal location and signal selection of UPFC device for damping oscillation , 2011 .
[23] Charles Concordia,et al. Concepts of Synchronous Machine Stability as Affected by Excitation Control , 1969 .
[24] N. Mithulananthan,et al. Linear performance indices to predict oscillatory stability problems in power systems , 2004, IEEE Transactions on Power Systems.