Application of microband array electrodes for end-column electrochemical detection in capillary electrophoresis

Abstract Microfabricated arrays consisting of four individually addressable band electrodes have been used for end-column electrochemical detection in capillary electrophoresis (CE). The commercially available array was positioned 75–300 μm from the capillary outlet of a 75 μm i.d. capillary in the absence of an electrical-field decoupler. The detector performance was studied using non-aqueous CE and capillary flow injection analysis (CFIA) experiments on the basis of an acetonitrile/acetate buffer and ferrocene compounds as model substances. Redox cycling was demonstrated to yield a noticeable enhancement of the detector signal for an electrode-capillary end distance of 300 μm, particularly when the working electrode was surrounded by two electrodes regenerating the detected species. For an electrode-capillary end distance of 75 μm, a collection efficiency of 25% was obtained for generation-collection experiments at the inner neighbour band electrodes under CE and CFIA conditions. Different combinations of the individual band electrodes were exploited for dual-electrode detection in CE determinations of aromatic amines. An improvement of selectivity could be demonstrated for the separation of p-aminophenol and N-benzoyl-N-phenylhydroxylamine. Using a single microband of the array as the sensing electrode in CE measurements, the limits of detection for (ferrocenylmethyl)trimethylammonium perchlorate and ferrocene were found to be 1.6×10−6 M and 1.5×10−6 M, respectively.

[1]  S. Lunte,et al.  Integrated on-capillary electrochemical detector for capillary electrophoresis. , 1996, Analytical chemistry.

[2]  A. Ewing,et al.  Characterization of Electrochemical Array Detection for Continuous Channel Electrophoretic Separations in Micrometer and Submicrometer Channels , 1997 .

[3]  L. Colón,et al.  Rudimentary capillary-electrode alignment for capillary electrophoresis with electrochemical detection. , 1996, Analytical chemistry.

[4]  W. Jin,et al.  Theory concerning the current for an end-column amperometric detector with a disk working electrode in capillary zone electrophoresis , 1997 .

[5]  R. Zare,et al.  Dual electrochemical detection of cysteine and cystine in capillary zone electrophoresis , 1994 .

[6]  F. Matysik Potentialities of electrochemical detection in conjunction with non-aqueous capillary electrophoresis , 1998 .

[7]  M. Smyth,et al.  Capillary electrophoresis with electrochemical detection employing an on-column Nafion joint , 1992 .

[8]  P. D. Voegel,et al.  Integrated Capillary Electrophoresis/Electrochemical Detection with Metal Film Electrodes Directly Deposited onto the Capillary Tip. , 1997, Analytical chemistry.

[9]  Andrew G. Ewing,et al.  Improved method for end-column amperometric detection for capillary electrophoresis , 1993 .

[10]  R. Zare,et al.  End-column detection for capillary zone electrophoresis. , 1991, Analytical chemistry.

[11]  A G Ewing,et al.  Flow injection analysis using continuous channel electrophoresis. , 1996, Analytical chemistry.

[12]  J. Slater,et al.  On-chip microband array electrochemical detector for use in capillary electrophoresis , 1994 .

[13]  F. Matysik,et al.  Electrochemical detection with microelectrodes in capillary flow systems , 1995 .

[14]  F. Matysik Non-aqueous capillary electrophoresis with electrochemical detection , 1998 .

[15]  Wenzhe Lu,et al.  End-column electrochemical detection for inorganic and organic species in high-voltage capillary electrophoresis , 1993 .

[16]  A. Ewing,et al.  Electrochemical detection in microcolumn separations. , 1994, Analytical chemistry.

[17]  F. Matysik Improved end-column amperometric detection for capillary electrophoresis , 1996 .

[18]  A. Ewing,et al.  Capillary zone electrophoresis with electrochemical detection. , 1987, Analytical chemistry.

[19]  S. Lunte,et al.  Dual-electrode detection for capillary electrophoresis/electrochemistry. , 1996, Analytical chemistry.

[20]  R. Baldwin,et al.  Amperometric detection in capillary electrophoresis with normal size electrodes , 1993 .

[21]  C. Whang,et al.  Capillary electrophoresis with amperometric detection using a porous cellulose acetate joint , 1993 .

[22]  W. Kok,et al.  Solid-state field decoupler for off-column detection in capillary electrophoresis , 1993 .