Time course of transmembrane voltage induced by time-varying electric fields—a method for theoretical analysis and its application

Abstract The paper describes a general method for analysis of time courses of transmembrane voltage induced by time-varying electric fields. Using this method, a response to a wide variety of time-varying fields can be studied. We apply it to different field shapes used for electroporation and electrofusion: rectangular pulses, trapezoidal pulses (approximating rectangular pulses with finite rise time), exponential pulses, and sine(RF)-modulated pulses. Using the described method, the course of induced transmembrane voltage is investigated for each selected pulse shape. All the studies are performed at different pulse durations, each for both the normal physiological and the low-conductivity medium. For all the pulse shapes investigated, it is shown that as the conductivity of extracellular medium is reduced, this slows down the process of transmembrane voltage inducement. Thus, longer pulses have to be used to attain the desired voltage amplitude, as the influence of the fast, short-lived phenomena on the induced voltage is diminished. Due to this reason, RF-modulation in such a medium is ineffective. The appendix gives a complete set of derived expressions and a discussion about possible simplifications.

[1]  W Krassowska,et al.  Response of a single cell to an external electric field. , 1994, Biophysical journal.

[2]  H. Itoh,et al.  Time courses of cell electroporation as revealed by submicrosecond imaging of transmembrane potential. , 1993, Biophysical journal.

[3]  E Neumann,et al.  Electric field mediated gene transfer. , 1982, Biochemical and biophysical research communications.

[4]  D Krebs,et al.  Electro-rotation of mouse oocytes: single-cell measurements of zona-intact and zona-free cells and of the isolated zona pellucida. , 1987, Biochimica et biophysica acta.

[5]  F. F. Becker,et al.  Numerical analysis of the influence of experimental conditions on the accuracy of dielectric parameters derived from electrorotation measurements , 1995 .

[6]  A. Sowers The Mechanism of Electroporation and Electrofusion in Erythrocyte Membranes , 1989 .

[7]  T. Tsong,et al.  Schwan equation and transmembrane potential induced by alternating electric field. , 1990, Biophysical journal.

[8]  Raymond M. Fuoss,et al.  Theory of dielectrics. , 1949 .

[9]  I. Lamprecht,et al.  Dielectric properties of yeast cells as determined by electrorotation. , 1992, Biochimica et biophysica acta.

[10]  D. Wicher,et al.  Electrorotation of multi- and oligolamellar liposomes☆ , 1989 .

[11]  U. Zimmermann,et al.  Alterations in the electrical properties of T and B lymphocyte membranes induced by mitogenic stimulation. Activation monitored by electro-rotation of single cells. , 1990, Biochimica et biophysica acta.

[12]  T. Tomov Quantitative dependence of electroporation on the pulse parameters , 1995 .

[13]  S. Snyder,et al.  Monoclonal antibody production by receptor-mediated electrically induced cell fusion , 1984, Nature.

[14]  E. Neumann,et al.  Electro-optics of membrane electroporation in diphenylhexatriene-doped lipid bilayer vesicles. , 1996, Biophysical chemistry.

[15]  K. Kaler,et al.  Dielectrophoretic spectra of single cells determined by feedback-controlled levitation. , 1990, Biophysical journal.

[16]  E. Neumann,et al.  Electroporation and Electrofusion in Cell Biology , 1989, Springer US.

[17]  R. Pethig,et al.  Membrane changes accompanying the induced differentiation of Friend murine erythroleukemia cells studied by dielectrophoresis. , 1993, Biochimica et biophysica acta.

[18]  D Miklavcic,et al.  Calculation of the electrical parameters in electrochemotherapy of solid tumours in mice , 1998, Comput. Biol. Medicine.

[19]  H P Schwan,et al.  Cellular membrane potentials induced by alternating fields. , 1992, Biophysical journal.

[20]  D. Chang,et al.  High efficiency gene transfection by electroporation using a radio-frequency electric field. , 1991, Biochimica et biophysica acta.

[21]  E. Tekle,et al.  Selective and asymmetric molecular transport across electroporated cell membranes. , 1994, Proceedings of the National Academy of Sciences of the United States of America.

[22]  J. Weaver,et al.  Theory of electroporation: A review , 1996 .

[23]  T. Tsong,et al.  Electroporation of cell membranes. , 1991, Biophysical journal.

[24]  K R Robinson,et al.  The responses of cells to electrical fields: a review , 1985, The Journal of cell biology.

[25]  G. Fuhr,et al.  Rotation of dielectrics in a rotating electric high-frequency field. Model experiments and theoretical explanation of the rotation effect of living cells. , 1986, Biophysical journal.

[26]  Benoît Roux,et al.  Biological membranes : a molecular perspective from computation and experiment , 1996 .

[27]  D. Chang,et al.  Cell poration and cell fusion using an oscillating electric field. , 1989, Biophysical journal.

[28]  Douglas B. Kell,et al.  The radio-frequency dielectric properties of yeast cells measured with a rapid, automated, frequency-domain dielectric spectrometer , 1983 .

[29]  M. Okino,et al.  Effects of a high-voltage electrical impulse and an anticancer drug on in vivo growing tumors. , 1987, Japanese journal of cancer research : Gann.

[30]  D. Chang,et al.  Guide to Electroporation and Electrofusion , 1991 .

[31]  H. Pauly,et al.  Über die Impedanz einer Suspension von kugelförmigen Teilchen mit einer Schale , 1959 .

[32]  G. Fuhr,et al.  Differences in the rotation spectra of mouse oocytes and zygotes. , 1987, Biochimica et biophysica acta.

[33]  James C. Weaver,et al.  Determination of the electric field and anomalous heating caused by exponential pulses with aluminum electrodes in electroporation experiments , 1996 .

[34]  Tadej Kotnik,et al.  Sensitivity of transmembrane voltage induced by applied electric fields—A theoretical analysis , 1997 .

[35]  Robert M. Fano,et al.  Electromagnetic Fields, Energy, and Forces , 1968 .