An adaptive Tikhonov regularization method for fluorescence molecular tomography

The high degree of absorption and scattering of photons propagating through biological tissues makes fluorescence molecular tomography (FMT) reconstruction a severe ill-posed problem and the reconstructed result is susceptible to noise in the measurements. To obtain a reasonable solution, Tikhonov regularization (TR) is generally employed to solve the inverse problem of FMT. However, with a fixed regularization parameter, the Tikhonov solutions suffer from low resolution. In this work, an adaptive Tikhonov regularization (ATR) method is presented. Considering that large regularization parameters can smoothen the solution with low spatial resolution, while small regularization parameters can sharpen the solution with high level of noise, the ATR method adaptively updates the spatially varying regularization parameters during the iteration process and uses them to penalize the solutions. The ATR method can adequately sharpen the feasible region with fluorescent probes and smoothen the region without fluorescent probes resorting to no complementary priori information. Phantom experiments are performed to verify the feasibility of the proposed method. The results demonstrate that the proposed method can improve the spatial resolution and reduce the noise of FMT reconstruction at the same time.

[1]  A. N. Tikhonov,et al.  Solutions of ill-posed problems , 1977 .

[2]  Hamid Dehghani,et al.  Improved quantification of small objects in near-infrared diffuse optical tomography. , 2004, Journal of biomedical optics.

[3]  S. Gambhir,et al.  Molecular imaging in living subjects: seeing fundamental biological processes in a new light. , 2003, Genes & development.

[4]  Gene H. Golub,et al.  Generalized cross-validation as a method for choosing a good ridge parameter , 1979, Milestones in Matrix Computation.

[5]  D Calvetti,et al.  An adaptive smoothness regularization algorithm for optical tomography. , 2008, Optics express.

[6]  Stefan Andersson-Engels,et al.  Spatially varying regularization based on spectrally resolved fluorescence emission in fluorescence molecular tomography. , 2007, Optics express.

[7]  R. Weissleder,et al.  Tomographic fluorescence mapping of tumor targets. , 2005, Cancer research.

[8]  Eric L. Miller,et al.  Data Specific Spatially Varying Regularization for Multimodal Fluorescence Molecular Tomography , 2010, IEEE Transactions on Medical Imaging.

[9]  M. Schweiger,et al.  The finite element method for the propagation of light in scattering media: boundary and source conditions. , 1995, Medical physics.

[10]  Michael Unser,et al.  Sparsity-Driven Reconstruction for FDOT With Anatomical Priors , 2011, IEEE Transactions on Medical Imaging.

[11]  Vasilis Ntziachristos,et al.  In vivo tomographic imaging of near-infrared fluorescent probes. , 2002, Molecular imaging.

[12]  Tianzi Jiang,et al.  Improving image quality of diffuse optical tomography with a projection-error-based adaptive regularization method. , 2008, Optics express.

[13]  Per Christian Hansen,et al.  Analysis of Discrete Ill-Posed Problems by Means of the L-Curve , 1992, SIAM Rev..

[14]  Otmar Scherzer,et al.  The use of Morozov's discrepancy principle for Tikhonov regularization for solving nonlinear ill-posed problems , 1993, Computing.

[15]  V Ntziachristos,et al.  Kirchhoff approximation for diffusive waves. , 2001, Physical review. E, Statistical, nonlinear, and soft matter physics.

[16]  Timothy J Rudge,et al.  Full-wavelet approach for fluorescence diffuse optical tomography with structured illumination. , 2010, Optics letters.

[17]  B. Pogue,et al.  Spatially variant regularization improves diffuse optical tomography. , 1999, Applied optics.

[18]  J. Ripoll,et al.  Fast analytical approximation for arbitrary geometries in diffuse optical tomography. , 2002, Optics letters.

[19]  Sree Harsha Katamreddy,et al.  Model-resolution based regularization improves near infrared diffuse optical tomography. , 2012, Journal of the Optical Society of America. A, Optics, image science, and vision.

[20]  Dianne P. O'Leary,et al.  The Use of the L-Curve in the Regularization of Discrete Ill-Posed Problems , 1993, SIAM J. Sci. Comput..

[21]  R. Weissleder,et al.  Fluorescence molecular imaging of small animal tumor models. , 2004, Current molecular medicine.

[22]  Minutes,et al.  MOLECULAR IMAGING IN DRUG DISCOVERY AND DEVELOPMENT , 2003 .

[23]  Andrea Bassi,et al.  Multiple-view fluorescence optical tomography reconstruction using compression of experimental data. , 2011, Optics letters.

[24]  Vasilis Ntziachristos,et al.  Experimental fluorescence tomography of tissues with noncontact measurements , 2004, IEEE Transactions on Medical Imaging.

[25]  J. Bai,et al.  A Parallel Excitation Based Fluorescence Molecular Tomography System for Whole-Body Simultaneous Imaging of Small Animals , 2010, Annals of Biomedical Engineering.

[26]  Timothy J Rudge,et al.  Fast image reconstruction in fluorescence optical tomography using data compression. , 2010, Optics letters.