Field practices of UHF technique for on-line PD monitoring and site testing of power transformers

A field-oriented UHF system for on-line PD monitoring of transformers is designed, which has been installed inside the oil tank of a 220 kV transformer in a substation of Henan Province by two ways: on-line installing mode through the oil-valve and preinstalling mode through the man hole/hand hole cover. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

[1]  O. Farish,et al.  Modelling partial discharge excitation of UHF signals in waveguide structures using Green's functions , 1996 .

[2]  Transformer monitoring using the UHF technique , 1999 .

[3]  M. D. Judd Transient calibration of electric field sensors , 1999 .

[4]  Martin D. Judd,et al.  A pulsed GTEM system for UHF sensor calibration , 1998, IEEE Trans. Instrum. Meas..

[5]  K. Raja,et al.  Source characterization of discharges in transformers using UHF PD signatures , 2002, 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309).

[6]  B. F. Hampton,et al.  Dielectric windows for UHF partial discharge detection , 2001 .

[7]  S. Lelaidier,et al.  Experience with UHF partial discharge measurements , 2002, Proceedings of 2002 IEEE 14th International Conference on Dielectric Liquids. ICDL 2002 (Cat. No.02CH37319).

[8]  R. Feger,et al.  Application of the CIGRE-sensitivity verification for UHF PD detection in three-phase GIS , 1999 .

[9]  Martin D. Judd,et al.  Applying UHF partial discharge detection to power transformers , 2002 .

[10]  Judd,et al.  Measurement of propagation characteristics for UHF signals in transformer insulation materials , 2003 .

[11]  Martin D. Judd,et al.  UHF couplers for gas-insulated substations: a calibration technique , 1997 .

[12]  B. F. Hampton,et al.  The excitation of UHF signals by partial discharges in GIS , 1996 .

[13]  Tang Ju,et al.  A calculational method of transient electric field excited by partial discharge in gas insulated substation using dyadic Green function , 2002, Proceedings. International Conference on Power System Technology.

[14]  Martin D. Judd,et al.  Broadband couplers for UHF detection of partial discharge in gas-insulated substations , 1995 .

[15]  Martin D. Judd,et al.  Recognising multiple partial discharge sources in power transformers by wavelet analysis of UHF signals , 2003 .

[16]  Judd,et al.  Propagation characteristics of UHF signals in transformers for locating partial discharge sources , 2003 .

[17]  K. Raja,et al.  Recognition of discharge sources using UHF PD signatures , 2002 .

[18]  Martin D. Judd Using finite difference time domain techniques to model electrical discharge phenomena , 2000, 2000 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.00CH37132).