Influence of the load modelling during gait on the stress distribution in a femoral implant

IntroductionWhen designing and installing implants, stress analyses should be performed in conditions close to those of everyday use. Specifically, for femoral implants, cyclic loading during gait has been demonstrated to produce fatigue failure. However, there is still no consensus in the literature regarding which modelling procedure is the most appropriate to simulate implant working conditions. This work proposes a method for realistic load modelling of the human body during gait based on flexible multibody dynamics.MethodThe proposed dynamic method was applied to a case study of a lower limb implant that failed by fatigue. The computed stresses were compared to the stresses obtained using the other three methods found in the literature, which are principally based on static or quasi-static load modelling.ResultsFor all compared methods, the maximum computed stress was located in the same region of the implant. The maximum stress provided using flexible multibody dynamics was equal to 346 MPa, which was 355% greater than the maximum value given by the static method and 18% greater than the value given by the quasi-static method.Discussion and conclusionThe proposed dynamic method was in agreement with the conclusions of the previous failure analysis performed on the broken implant. Conversely, the static and quasi-static methods were not representative of the real loading conditions induced by gait. Moreover, the dynamic method emphasizes the pertinence of evaluating the fluctuations in the critical stress during the gait cycle, which is mandatory when studying fatigue failures.

[1]  M J Pearcy,et al.  Computational investigations of mechanical failures of internal plate fixation , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[2]  S Nobari,et al.  Three-dimensional design optimisation of patient-specific femoral plates as a means of bone remodelling reduction , 2010, Computer methods in biomechanics and biomedical engineering.

[3]  Taeyong Lee,et al.  Improving stability of locking compression plates through a design modification: a computational investigation , 2015, Computer methods in biomechanics and biomedical engineering.

[4]  M. Bampton,et al.  Coupling of substructures for dynamic analyses. , 1968 .

[5]  Ching-Hua Hung,et al.  Finite element comparison of retrograde intramedullary nailing and locking plate fixation with/without an intramedullary allograft for distal femur fracture following total knee arthroplasty. , 2014, The Knee.

[6]  P. Regazzoni,et al.  Understanding Fracture Healing Biomechanics Based on the "Strain" Concept and its Clinical Applications. , 2015, Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca.

[7]  Joshua C. Arnone,et al.  Computer-Aided Engineering Approach for Parametric Investigation of Locked Plating Systems Design , 2013 .

[8]  N. Verdonschot,et al.  Subject-specific musculoskeletal loading of the tibia: Computational load estimation. , 2017, Journal of the mechanical behavior of biomedical materials.

[9]  G. Pharr,et al.  The elastic properties of trabecular and cortical bone tissues are similar: results from two microscopic measurement techniques. , 1999, Journal of biomechanics.

[10]  R. B. Davis,et al.  A gait analysis data collection and reduction technique , 1991 .

[11]  K. Bathe,et al.  Component mode synthesis with subspace iterations for controlled accuracy of frequency and mode shape solutions , 2014 .

[12]  Pankaj Pankaj,et al.  Does screw-bone interface modelling matter in finite element analyses? , 2012, Journal of biomechanics.

[13]  Hartmut Witte,et al.  ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics. , 2002, Journal of biomechanics.

[14]  W. Taylor,et al.  Physiologically based boundary conditions in finite element modelling. , 2007, Journal of biomechanics.

[15]  Timo Rantalainen,et al.  Flexible multibody approach in forward dynamic simulation of locomotive strains in human skeleton with flexible lower body bones , 2011 .

[16]  H. Vallier,et al.  Failure of LCP condylar plate fixation in the distal part of the femur. A report of six cases. , 2006, The Journal of bone and joint surgery. American volume.

[17]  A L Yettram,et al.  Finite element analysis of a Gamma nail within a fractured femur. , 1998, Medical engineering & physics.

[18]  R. Nazer,et al.  Analysis of dynamic strains in tibia during human locomotion based on flexible multibody approach integrated with magnetic resonance imaging technique , 2008 .

[19]  S. Hoppenfeld,et al.  Treatment and Rehabilitation of Fractures , 2000 .

[20]  I-Min Lee,et al.  The importance of walking to public health. , 2008, Medicine and science in sports and exercise.

[21]  Maxime Raison,et al.  Failure analysis of a 316L stainless steel femoral orthopedic implant , 2016 .

[22]  R Al Nazer,et al.  Flexible multibody simulation approach in the analysis of tibial strain during walking. , 2008, Journal of biomechanics.

[23]  Joseph Hidler,et al.  Abnormal joint torque patterns exhibited by chronic stroke subjects while walking with a prescribed physiological gait pattern , 2008, Journal of NeuroEngineering and Rehabilitation.

[24]  Irving P. Herman,et al.  Physics of the Human Body , 2008 .

[25]  A. Mikkola,et al.  The use of the flexible multibody approach for lower body skeletal loading analysis , 2011 .

[26]  J. Clement,et al.  A comparison of cortical bone thickness in the femoral midshaft of humans and two non-human mammals. , 2009, Homo : internationale Zeitschrift fur die vergleichende Forschung am Menschen.

[27]  J J O'Connor,et al.  Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints. , 1999, Journal of biomechanics.

[28]  David A. Winter,et al.  Biomechanics and Motor Control of Human Movement , 1990 .

[29]  J. Cegoñino,et al.  A Comparative Analysis of Different Treatments for Distal Femur Fractures using the Finite Element Method , 2004, Computer methods in biomechanics and biomedical engineering.

[30]  Aki Mikkola,et al.  Pilot study on proximal femur strains during locomotion and fall-down scenario , 2012 .

[31]  Fuchuan Jiang,et al.  THE HIP STRESS LEVEL ANALYSIS FOR HUMAN ROUTINE ACTIVITIES , 2005 .

[32]  R Al Nazer,et al.  A full body musculoskeletal model based on flexible multibody simulation approach utilised in bone strain analysis during human locomotion , 2011, Computer methods in biomechanics and biomedical engineering.

[33]  M. Kojic,et al.  Internal Fixation of Femoral Bone Comminuted Fracture - FE Analysis , 2007 .

[34]  G. Bergmann,et al.  Hip contact forces and gait patterns from routine activities. , 2001, Journal of biomechanics.