Technical challenges for FLASH proton therapy.

There is growing interest in the radiotherapy community in the application of FLASH radiotherapy, wherein the dose is delivered to the entire treatment volume in less than a second. Early pre-clinical evidence suggests that these extremely high dose rates provide significant sparing of healthy tissue compared to conventional radiotherapy without reducing the damage to cancerous cells. This interest has been reflected in the proton therapy community, with early tests indicating that the FLASH effect is also present with high dose rate proton irradiation. In order to deliver clinically relevant doses at FLASH dose rates significant technical hurdles must be overcome in the accelerator technology before FLASH proton therapy can be realised. Of these challenges, increasing the average current from the present clinical range of 1-10 nA to in excess of 100 nA is at least feasible with existing technology, while the necessity for rapid energy adjustment on the order of a few milliseconds is much more challenging, particularly for synchrotron-based systems. However, the greatest challenge is to implement full pencil beam scanning, where scanning speeds 2 orders of magnitude faster than the existing state-of-the-art will be necessary, along with similar improvements in the speed and accuracy of associated dosimetry. Hybrid systems utilising 3D-printed patient specific range modulators present the most likely route to clinical delivery. However, to correctly adapt and develop existing technology to meet the challenges of FLASH, more pre-clinical studies are needed to properly establish the beam parameters that are necessary to produce the FLASH effect.

[1]  Yoshiyuki Iwata,et al.  Experimental studies of systematic multiple-energy operation at HIMAC synchrotron , 2014 .

[2]  M. Vozenin,et al.  Expanding the therapeutic index of radiation therapy by normal tissue protection. , 2018, The British journal of radiology.

[3]  M. Seidel,et al.  Large energy acceptance gantry for proton therapy utilizing superconducting technology , 2019, Physics in medicine and biology.

[4]  T. Haberer,et al.  Slow Extraction Techniques at the Marburg Ion-Beam Therapy Centre , 2018 .

[5]  B. Loo,et al.  Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator. , 2017, International journal of radiation oncology, biology, physics.

[6]  H. Kawai,et al.  Global spill control in RF-knockout slow-extraction , 2004 .

[7]  M. Pivi,et al.  Betatron Core Driven Slow Extraction at CNAO and MedAustron , 2016 .

[8]  Eike Feldmeier,et al.  The intensity feedback system at Heidelberg Ion-Beam Therapy Centre , 2015 .

[9]  Saverio Braccini,et al.  High Frequency Linacs for Hadrontherapy , 2009 .

[10]  M. Giannelli,et al.  Ion recombination correction for very high dose-per-pulse high-energy electron beams. , 2005, Medical physics.

[11]  K. Hiramoto,et al.  Development of a Compact Synchrotron for Proton Beam Therapy , 2017 .

[12]  Antony J. Lomax,et al.  Current and future accelerator technologies for charged particle therapy , 2016 .

[13]  S Ballestrero,et al.  Status of the Commissioning of the LIGHT Prototype , 2018 .

[14]  Andrew M. Sessler,et al.  Carbon/proton therapy: A novel gantry design , 2007 .

[15]  S. Caspi,et al.  Design of an Achromatic Superconducting Magnet for a Proton Therapy Gantry , 2017, IEEE Transactions on Applied Superconductivity.

[16]  D. Brenner,et al.  Biological effects in normal cells exposed to FLASH dose rate protons. , 2019, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[17]  A. Seville,et al.  Progress on dual harmonic acceleration on the isis synchrotron , 2007, 2007 IEEE Particle Accelerator Conference (PAC).

[18]  J. Shamblin,et al.  Proton therapy delivery: What is needed in the next ten years? , 2020, The British journal of radiology.

[19]  M. Furusaka,et al.  A new SOBP-formation method by superposing specially shaped Bragg curves formed by a mini-ridge filter for spot scanning in proton beam therapy. , 2019, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[20]  Eros Pedroni,et al.  Pencil beam characteristics of the next-generation proton scanning gantry of PSI: design issues and initial commissioning results , 2011 .

[21]  M. Durante,et al.  A new facility for proton radiobiology at the Trento proton therapy centre: Design and implementation. , 2019, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[22]  O Jäkel,et al.  Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization. , 2000, Physics in medicine and biology.

[23]  H. Paganetti Relating the proton relative biological effectiveness to tumor control and normal tissue complication probabilities assuming interpatient variability in α/β , 2017, Acta oncologica.

[24]  S. Psoroulas,et al.  Geometry optimisation of graphite energy degrader for proton therapy. , 2020, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[25]  J. Bourhis,et al.  Clinical translation of FLASH radiotherapy: Why and how? , 2019, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[26]  Lei Dong,et al.  Design, Implementation, and in Vivo Validation of a Novel Proton FLASH Radiation Therapy System. , 2020, International journal of radiation oncology, biology, physics.

[27]  Tianyu Zhao,et al.  Two‐stage ionoacoustic range verification leveraging Monte Carlo and acoustic simulations to stably account for tissue inhomogeneity and accelerator–specific time structure – A simulation study , 2018, Medical physics.

[28]  J. Hendry,et al.  Biological Benefits of Ultra-high Dose Rate FLASH Radiotherapy: Sleeping Beauty Awoken. , 2019, Clinical oncology (Royal College of Radiologists (Great Britain)).

[29]  J. Bourhis,et al.  The Advantage of FLASH Radiotherapy Confirmed in Mini-pig and Cat-cancer Patients , 2018, Clinical Cancer Research.

[30]  A. Gerbershagen,et al.  Measurements and simulations of boron carbide as degrader material for proton therapy , 2016, Physics in medicine and biology.

[31]  P. Poortmans,et al.  Experimental Set-up for FLASH Proton Irradiation of Small Animals Using a Clinical System. , 2018, International journal of radiation oncology, biology, physics.

[32]  W Enghardt,et al.  Characterization of the microbunch time structure of proton pencil beams at a clinical treatment facility , 2016, Physics in medicine and biology.

[33]  M. Brand,et al.  Feasibility of proton FLASH effect tested by zebrafish embryo irradiation. , 2019, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[34]  Tomasz Szumlak,et al.  Development of the LHCb VELO Detector Modules into a Standalone, Non-Invasive Online Beam Monitor for Medical Accelerators , 2018, Instruments.

[35]  B Vojnovic,et al.  Revisiting the ultra-high dose rate effect: implications for charged particle radiotherapy using protons and light ions. , 2012, The British journal of radiology.

[36]  OPERATION OF A CYCLOTRON BASED PROTON THERAPY FACILITY , 2005 .

[37]  Simon Zaremba,et al.  Cyclotrons: Magnetic Design and Beam Dynamics , 2017, 1804.08961.

[38]  M. Yoon,et al.  Design of a compact gantry for carbon-ion beam therapy , 2019, Physical Review Accelerators and Beams.

[39]  J. Bourhis,et al.  High dose‐per‐pulse electron beam dosimetry — A model to correct for the ion recombination in the Advanced Markus ionization chamber , 2017, Medical physics.

[40]  E. Pedroni,et al.  The SC cyclotron and beam lines of PSI’s new protontherapy facility PROSCAN , 2007 .

[41]  R. Engenhart-Cabillic,et al.  3D range-modulator for scanned particle therapy: development, Monte Carlo simulations and experimental evaluation , 2017, Physics in medicine and biology.

[42]  J. Bourhis,et al.  X-rays can trigger the FLASH effect: Ultra-high dose-rate synchrotron light source prevents normal brain injury after whole brain irradiation in mice. , 2018, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[43]  D C Weber,et al.  A beam monitoring and validation system for continuous line scanning in proton therapy , 2017, Physics in medicine and biology.

[44]  J. Thomason The ISIS Spallation Neutron and Muon Source—The first thirty-three years , 2019, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment.

[45]  E. Forton,et al.  The S2C2: From Source to Extraction , 2017 .

[46]  Marco Durante,et al.  Faster and safer? FLASH ultra-high dose rate in radiotherapy. , 2017, The British journal of radiology.

[47]  J. Bourhis,et al.  Treatment of a first patient with FLASH-radiotherapy. , 2019, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[48]  Danielle A. Simmons,et al.  Reduced cognitive deficits after FLASH irradiation of whole mouse brain are associated with less hippocampal dendritic spine loss and neuroinflammation. , 2019, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[49]  Philippe Hupé,et al.  Ultrahigh dose-rate FLASH irradiation increases the differential response between normal and tumor tissue in mice , 2014, Science Translational Medicine.

[50]  K. Saito,et al.  ACCELERATOR DEVELOPMENT FOR ADVANCED PARTICLE BEAM THERAPY , 2008 .

[51]  E. Keil,et al.  Hadron cancer therapy complex using nonscaling fixed field alternating gradient accelerator and gantry design , 2007 .

[52]  Wei Liu,et al.  Multiple energy extraction reduces beam delivery time for a synchrotron-based proton spot-scanning system , 2018, Advances in radiation oncology.

[53]  J M Schippers,et al.  2D dosimetry in a proton beam with a scintillating GEM detector , 2009, Physics in medicine and biology.

[54]  Pierpaolo Stabile,et al.  LIGHT: A Linear Accelerator for Proton Therapy , 2017 .

[55]  S. L. Smith,et al.  Hadron accelerators for radiotherapy , 2014 .

[56]  Mark Johnson,et al.  Impact of the high magnetic field and RF power in a superconducting cyclotron on the operation of a nearby MRI facility , 2016 .

[57]  Michael Baumann,et al.  TCP and NTCP: a basic introduction. , 2005, Rays.

[58]  David Robin,et al.  Alternating-gradient canted cosine theta superconducting magnets for future compact proton gantries , 2015 .

[59]  A. Lomax,et al.  Towards FLASH proton therapy: the impact of treatment planning and machine characteristics on achievable dose rates , 2019, Acta oncologica.