Implementation of the Varian EDW into a commercial RTP system.

An enhanced dynamic wedge system (EDW) has been installed onto our Clinac 600C (6 MV) linear accelerator. This paper addresses and describes the measurements taken and subsequent analysis required to enable the planning of EDW using our commercial radiotherapy treatment planning (RTP) system. This implementation into a 'closed' commercial system is performed without the use of specialized measurement equipment or the necessity of introducing new calculation algorithms and is therefore independent of the RTP manufacturer. We consider that, for incorporation of techniques such as EDW into routine clinical use, a simple verifiable method of inclusion into the RTP system must be achieved. This paper also presents a methodology for quality control of dynamic fields chosen for clinical use which is quick and easy to use by virtue of its use of film dosimetry. We present the method of film calibration used in this work.

[1]  S. Thomas,et al.  Radiotherapy treatment planning with dynamic wedges--an algorithm for generating wedge factors and beam data. , 1995, Physics in medicine and biology.

[2]  W Sewchand,et al.  Revision of tissue-maximum ratio and scatter-maximum ratio concepts for cobalt 60 and higher energy x-ray beams. , 1980, Medical physics.

[3]  D A Low,et al.  Dosimetry and clinical implementation of dynamic wedge. , 1995, International Journal of Radiation Oncology, Biology, Physics.

[4]  A. Welsh,et al.  An investigation into the comparison between different dosimetric methods of measuring profiles and depth doses for dynamic wedges on a Varian 600C linear accelerator. , 1995, Physics in medicine and biology.

[5]  C. Yu,et al.  A method for implementing dynamic photon beam intensity modulation using independent jaws and a multileaf collimator. , 1995, Physics in medicine and biology.

[6]  D. Leavitt,et al.  Evaluation of a diode detector array for measurement of dynamic wedge dose distributions. , 1993, Medical physics.

[7]  S C Sharma,et al.  Film dosimetry of megavoltage photon beams: a practical method of isodensity-to-isodose curve conversion. , 1981, Medical physics.

[8]  D D Leavitt,et al.  Dynamic wedge field techniques through computer-controlled collimator motion and dose delivery. , 1990, Medical physics.

[9]  P. Childs,et al.  Beam data measurements for dynamic wedges on Varian 600C (6 MV) and 2100C (6 and 10 MV) linear accelerators. , 1995, Physics in medicine and biology.