CT-guided agar marking for localization of nonpalpable peripheral pulmonary lesions.

BACKGROUND Small pulmonary lesions with ground-glass opacity (GGO) are increasingly detected by CT; however, intraoperative localization of such lesions is difficult because these lesions are often invisible and nonpalpable. STUDY OBJECTIVES To localize and resect nonpalpable and invisible small pulmonary lesions, a new marking technique that we call "agar marking" was developed. METHODS AND PATIENTS Powdered agar was dissolved in distilled water at a concentration of 5% and kept at > 50 degrees C to maintain its liquid form. Agar was injected through an 18-gauge needle and placed near the target lesion with CT. After animal experiments, agar marking was applied to the nine patients who had lesions < 20 mm in diameter and lesions with GGO. The mean diameter of these lesions was 11 mm, with a mean depth of 19 mm from the pleural surface on CT. RESULTS Agar could be detected as a hard nodule by manual palpation, and the lesion was resected during thoracotomy in all cases. There were no complications associated with the agar injection, aside from one case of slight pneumothorax. CONCLUSIONS Agar marking may represent a feasible alternative technique for localizing nonpalpable occult lesions located away from the pleural surface.

[1]  J. Ochsner,et al.  Thoracotomy through the auscultatory triangle. , 1989, The Annals of thoracic surgery.

[2]  H. Shennib Intraoperative localization techniques for pulmonary nodules. , 1993, The Annals of thoracic surgery.

[3]  M. Crittenden,et al.  Methylene blue guidance for simplified resection of a lung lesion. , 1992, The Annals of thoracic surgery.

[4]  M. Berger,et al.  Percutaneous localization of pulmonary nodules for thoracoscopic lung resection. , 1992, The Annals of thoracic surgery.

[5]  E J Stern,et al.  Ground-glass opacity at CT: the ABCs. , 1997, AJR. American journal of roentgenology.

[6]  M. Mack,et al.  Techniques for localization of pulmonary nodules for thoracoscopic resection. , 1993, The Journal of thoracic and cardiovascular surgery.

[7]  A Guermazi,et al.  The hook-wire technique for localization of pulmonary nodules during thoracoscopic resection. , 1994, Chest.

[8]  M. Naito,et al.  Cloudy nodule on HRCT: a new clinico-radiologic entity of pulmonary adenocarcinoma. , 1995, Radiation medicine.

[9]  H. Horio,et al.  Colored collagen is a long-lasting point marker for small pulmonary nodules in thoracoscopic operations. , 1996, The Annals of thoracic surgery.

[10]  S. Omata,et al.  Application of a new tactile sensor to thoracoscopic surgery: experimental and clinical study. , 1995, The Annals of thoracic surgery.

[11]  M. Kaneko,et al.  Computed tomography-guided coil injection and thoracoscopic pulmonary resection under roentgenographic fluoroscopy. , 1994, The Annals of thoracic surgery.

[12]  K. S. Lee,et al.  Localized form of bronchioloalveolar carcinoma: FDG PET findings. , 1998, AJR. American journal of roentgenology.

[13]  H. Shennib,et al.  Intraoperative transthoracic ultrasonographic localization of occult lung lesions. , 1993, The Annals of thoracic surgery.