Multi-frequency electrical impedance tomography (EIT) of the adult human head: initial findings in brain tumours, arteriovenous malformations and chronic stroke, development of an analysis method and calibration

MFEIT (multi-frequency electrical impedance tomography) could distinguish between ischaemic and haemorrhagic stroke and permit the urgent use of thrombolytic drugs in patients with ischaemic stroke. The purpose of this study was to characterize the UCLH Mk 2 MFEIT system, designed for this purpose, with 32 electrodes and a multiplexed 2 kHz to 1.6 MHz single impedance measuring circuit. Data were collected in seven subjects with brain tumours, arteriovenous malformations or chronic stroke, as these resembled the changes in haemorrhagic or ischaemic stroke. Calibration studies indicated that the reliable bandwidth was only 16-64 kHz because of front-end components placed to permit simultaneous EEG recording. In raw in-phase component data, the SD of 16-64 kHz data for one electrode combination across subjects was 2.45 +/- 0.9%, compared to a largest predicted change of 0.35% estimated using the FEM of the head. Using newly developed methods of examining the most sensitive channels from the FEM, and nonlinear imaging constrained to the known site of the lesion, no reproducible changes between pathologies were observed. This study has identified a specification for accuracy in EITS in acute stroke, identified the size of variability in relation to this in human recordings, and presents new methods for analysis of data. Although no reproducible changes were identified, we hope this will provide a foundation for future studies in this demanding but potentially powerful novel application.

[1]  R. Pethig,et al.  Dielectric properties of body tissues. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[2]  J. B. Ranck,et al.  THE SPECIFIC IMPEDANCE OF THE DORSAL COLUMNS OF CAT: AN INISOTROPIC MEDIUM. , 1965, Experimental neurology.

[3]  E. Haber,et al.  Inversion of 3D electromagnetic data in frequency and time domain using an inexact all-at-once approach , 2004 .

[4]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[5]  C D Cone,et al.  Induction of mitosis in mature neurons in central nervous system by sustained depolarization. , 1976, Science.

[6]  C Gabriel,et al.  The dielectric properties of biological tissues: I. Literature survey. , 1996, Physics in medicine and biology.

[7]  L Horesha,et al.  Could synchronized neuronal activity be imaged using Low Frequency Electrical Impedance Tomography (LFEIT) , 2005 .

[8]  Stuchly,et al.  Dielectric properties of breast carcinoma and the surrounding tissues , 1988, IEEE Transactions on Biomedical Engineering.

[9]  J. B. Ranck,et al.  Specific impedance of rabbit cerebral cortex. , 1963, Experimental neurology.

[10]  R H Bayford,et al.  Electrical impedance tomography spectroscopy (EITS) for human head imaging. , 2003, Physiological measurement.

[11]  A Adler,et al.  Electrical impedance tomography can monitor dynamic hyperinflation in dogs. , 1998, Journal of applied physiology.

[12]  D. Marquardt An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .

[13]  T. Osborn,et al.  Intravenous thrombolytic therapy for stroke: a review of recent studies and controversies. , 1999, Annals of emergency medicine.

[14]  D S Holder,et al.  Use of polyacrylamide gels in a saline-filled tank to determine the linearity of the Sheffield Mark 1 electrical impedance tomography (EIT) system in measuring impedance disturbances. , 1994, Physiological measurement.

[15]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[16]  Lior Horesh,et al.  Stroke type differentiation by multi-frequency electrical impedance tomography—a feasibility study , 2005 .

[17]  Dieter Haemmerich,et al.  In vivo electrical conductivity of hepatic tumours. , 2003, Physiological measurement.

[18]  A Tizzard,et al.  Generating accurate finite element meshes for the forward model of the human head in EIT , 2005, Physiological measurement.

[19]  Patricia Brunner,et al.  Direct reconstruction of tissue parameters from differential multifrequency EIT in vivo , 2006, Physiological measurement.

[20]  Simon R. Arridge,et al.  Stroke type detection by multi-frequency electrical impedance tomography MFEIT—a feasibility study , 2005 .

[21]  Richard H. Bayford,et al.  Three-Dimensional Electrical Impedance Tomography of Human Brain Activity , 2001, NeuroImage.

[22]  R H Smallwood,et al.  Mk3.5: a modular, multi-frequency successor to the Mk3a EIS/EIT system. , 2001, Physiological measurement.

[23]  J. B. Ranck,et al.  Specific impedance of cerebral cortex during spreading depression, and an analysis of neuronal, neuroglial, and interstitial contributions , 1964 .

[24]  G. Hankey,et al.  Treatment and secondary prevention of stroke: evidence, costs, and effects on individuals and populations* , 1999, The Lancet.

[25]  D. Holder,et al.  Large-Scale Non-Linear 3D Reconstruction Algorithms for Electrical Impedance Tomography of the Human Head , 2007 .

[26]  J. B. Ranck,et al.  Analysis of specific impedance of rabbit cerebral cortex. , 1963, Experimental neurology.

[27]  R H Bayford,et al.  A comparison of headnet electrode arrays for electrical impedance tomography of the human head. , 2003, Physiological measurement.

[28]  Kenneth Levenberg A METHOD FOR THE SOLUTION OF CERTAIN NON – LINEAR PROBLEMS IN LEAST SQUARES , 1944 .

[29]  J. Newell,et al.  Distinguishability of inhomogeneities using planar electrode arrays and different patterns of applied excitation. , 2003, Physiological measurement.

[30]  B H Brown,et al.  Electrical impedance tomography (EIT): a review , 2003, Journal of medical engineering & technology.