Reproducibility of Angle Metrics Using the Time-Domain Anterior Segment Optical Coherence Tomography: Intra-Observer and Inter-Observer Variability

Abstract Purpose: To evaluate the reproducibility of anterior chamber angle measurements obtained by the Zeiss Visante anterior segment optical coherence tomography (AS-OCT). Methods: Twenty eyes from 20 normal subjects with open anterior chamber angles were studied. The anterior chamber angle was imaged using the Visante AS-OCT. The angle-opening distance (AOD 500, AOD 750), trabercular iris space area (TISA 500, TISA 750) and scleral spur angle (SS angle) at the inferior angle location were measured. All the subjects underwent imaging in a darkened room (1 foot candles measured at the eye). Images were graded in a masked fashion by certified Doheny Image Reading Center graders. For intra-grader reproducibility assessments, images were re-graded by the same grader 1 week later after random sorting of images. For inter-grader assessments, a second masked grader independently reviewed the images. Intraclass correlation coefficients (ICC) were used to assess reproducibility. Results: Inferior angle measurements of AOD (500, 750), TISA (500, 750) and SS angle for 20 normal eyes were calculated. The intra-observer ICC calculations showed excellent reproducibility for all measurements (AOD 500 = 0.95, AOD 750 = 0.97, TISA 500 = 0.93, TISA 750 = 0.94, SS = 0.96; p < 0.001 for all). The inter-observer ICC calculations showed lower reproducibility for all measurements (AOD 500 = 0.71, p < 0.001; AOD 750 = 0.82, p < 0.001; TISA 500 = 0.49, p = 0.08; TISA 750 = 0.61, p = 0.02; SS = 0.75). Conclusion: Determination of anterior chamber angle measurements was possible with the time-domain AS-OCT, but only modest inter-observer reproducibility was found even among experienced graders.

[1]  C Tello,et al.  Measurement of ultrasound biomicroscopy images: intraobserver and interobserver reliability. , 1994, Investigative ophthalmology & visual science.

[2]  J S Tiedeman,et al.  Ultrasound biomicroscopic quantitative analysis of light-dark changes associated with pupillary block. , 1999, American journal of ophthalmology.

[3]  Y M Buys,et al.  Ultrasound biomicroscopic quantitative analysis of light-dark changes associated with pupillary block. , 1999, American journal of ophthalmology.

[4]  Robert Ritch,et al.  Dynamic analysis of dark-light changes of the anterior chamber angle with anterior segment OCT. , 2007, Investigative ophthalmology & visual science.

[5]  Jing Tian,et al.  Automatic Anterior Chamber Angle Assessment for HD-OCT Images , 2011, IEEE Transactions on Biomedical Engineering.

[6]  Shan C. Lin,et al.  Anterior segment optical coherence tomography as a screening tool for the assessment of the anterior segment angle. , 2009, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[7]  R Ritch,et al.  Ultrasound biomicroscopy dark room provocative testing: a quantitative method for estimating anterior chamber angle width. , 1999, Japanese journal of ophthalmology.

[8]  Tin Aung,et al.  Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography. , 2007, Investigative ophthalmology & visual science.

[9]  David Huang,et al.  Optical coherence tomography assessment of angle anatomy changes after cataract surgery. , 2007, American journal of ophthalmology.

[10]  J. Dawczynski,et al.  Anterior optical coherence tomography: a non-contact technique for anterior chamber evaluation , 2007, Graefe's Archive for Clinical and Experimental Ophthalmology.

[11]  G. Dahmen,et al.  Anterior chamber angle measurement with optical coherence tomography: Intraobserver and interobserver variability , 2006, Journal of cataract and refractive surgery.

[12]  C. Leung,et al.  Visualization of anterior chamber angle dynamics using optical coherence tomography. , 2005, Ophthalmology.

[13]  Sunita Radhakrishnan,et al.  Reproducibility of Scleral Spur Identification and Angle Measurements Using Fourier Domain Anterior Segment Optical Coherence Tomography , 2012, Journal of ophthalmology.

[14]  Tin Aung,et al.  High-definition optical coherence tomography imaging of the iridocorneal angle of the eye. , 2009, Archives of ophthalmology.

[15]  R Ritch,et al.  Inadvertent corneal indentation can cause artifactitious widening of the iridocorneal angle on ultrasound biomicroscopy. , 2000, Ophthalmic surgery and lasers.

[16]  J. Duker,et al.  Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography. , 2005, Ophthalmology.

[17]  J. K. Pedersen,et al.  Ultrasound biomicroscopy. II. Intraobserver and interobserver reproducibility of measurements. , 1998, Acta ophthalmologica Scandinavica.

[18]  Kyung R Sung,et al.  Characteristics and reproducibility of anterior chamber angle assessment by anterior‐segment optical coherence tomography , 2011, Acta ophthalmologica.

[19]  Yan Li,et al.  Anterior segment optical coherence tomography for imaging the anterior chamber after laser peripheral iridotomy. , 2007, American journal of ophthalmology.

[20]  Shuliang Jiao,et al.  Simultaneous acquisition of sectional and fundus ophthalmic images with spectral-domain optical coherence tomography. , 2005, Optics express.

[21]  C. Costagliola,et al.  Enhanced depth imaging spectral-domain optical coherence tomography. , 2010, Retina.

[22]  D. Friedman,et al.  Quantitative analysis of anterior segment optical coherence tomography images: the Zhongshan Angle Assessment Program , 2008, British Journal of Ophthalmology.

[23]  F. Bandello,et al.  Anterior Chamber Angle Assessment Techniques , 2011 .

[24]  C. Cheung,et al.  Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography , 2007, British Journal of Ophthalmology.

[25]  Tin Aung,et al.  Assessment of the scleral spur in anterior segment optical coherence tomography images. , 2008, Archives of ophthalmology.