Initial experimentation with in-line holography x-ray phase-contrast imaging with an ultrafast laser-based x-ray source

We have investigated experimentally and theoretically the imaging performance of our newly constructed in-line holography x-ray phase-contrast imaging system with an ultrafast laser-based x-ray source. Projection images of nylon fibers with diameters in the 10-330 μm range were obtained using an ultrafast (100 Hz, 28 fs, 40 mJ) laser-based x-ray source with Mo and Ta targets and Be filter, and Gaussian spatial-intensity distribution (FWHMS = 5 μm). A cooled CCD camera (24 μm pitch) with a Gd2OS2 screen coupled via 1:1 optical taper was used (FWHMD = 50 μm). We have investigated nylon-fiber image quality vs. imaging setup geometry and x-ray spectra. The following parameters were evaluated: contrast, signal-to-noise ratio (SNR), resolution, and sampling. In addition, we performed theoretical simulation of image formation for the same objects but within a wide range of geometrical parameters. The rigorous wave-optical formalism was used for modeling of the free-space propagation of x-rays from the object plane to the detector, and the "projection approximation" was used. We found reasonable agreement between predictions of our analytical model and the experiments. We conclude that: a) Optimum magnification maximizing contrast and SNR is almost independent of the source-to-detector (R) distance and depends strongly on the diameter of the fiber. b) The corresponding maximum values of the contrast and SNR are almost linear with respect to R; the optimum magnification decreases with fiber diameter. c) The minimum diameter of fiber defines the minimum source-to-object distance R1 if R is fixed and the object is moved.

[1]  S. Wilkins,et al.  Contrast and resolution in imaging with a microfocus x-ray source , 1997 .

[2]  Alexander Sasov,et al.  High-resolution in-vivo micro-CT scanner for small animals , 2002, Optics + Photonics.

[3]  M J Paulus,et al.  High resolution X-ray computed tomography: an emerging tool for small animal cancer research. , 2000, Neoplasia.

[4]  T E Gureyev,et al.  Quantitative analysis of two-component samples using in-line hard X-ray images. , 2002, Journal of synchrotron radiation.

[5]  S. W. Wilkins,et al.  Quantitative methods in phase-contrast x-ray imaging , 2000, Journal of Digital Imaging.

[6]  Horst Halling,et al.  Preliminary studies of a micro-CT for a combined small animal PET/CT scanner , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[7]  Timur E. Gureyev,et al.  On x-ray phase imaging with a point source , 1998 .

[8]  S. Fourmaux,et al.  Evaluation of ultrafast laser-based hard x-ray sources for phase-contrast imaging , 2007 .

[9]  Eric C. Frey,et al.  Development and evaluation of a MicroCT system for small animal imaging , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[10]  S. Wilkins,et al.  On the optimization of experimental parameters for x-ray in-line phase-contrast imaging , 2005 .

[11]  S. Wilkins,et al.  On X-ray phase retrieval from polychromatic images , 1998 .

[12]  Anatoly Snigirev,et al.  Hard x-ray quantitative noninterferometric phase-contrast imaging , 1999, Medical Imaging.

[13]  Hong Liu,et al.  An experimental method of determining relative phase-contrast factor for x-ray imaging systems. , 2004, Medical physics.

[14]  S. Wilkins,et al.  Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.

[15]  B. H. Hasegawa,et al.  Design of combined X-ray CT and SPECT systems for small animals , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[16]  Tokiko Endo,et al.  [X-ray phase imaging using a X-ray tube with a small focal spot -improvement of image quality in mammography-]. , 2002, Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics.

[17]  David R Pickens,et al.  Quantification of the effect of system and object parameters on edge enhancement in phase-contrast radiography. , 2003, Medical physics.