How Do Annuloplasty Rings Affect Mitral Annular Strains in the Normal Beating Ovine Heart?

Background— We hypothesized that annuloplasty ring implantation alters mitral annular strains in a normal beating ovine heart preparation. Methods and Results— Sheep had 16 radiopaque markers sewn equally spaced around the mitral annulus. Edwards Cosgrove partial flexible band (COS; n=12), St Jude complete rigid saddle-shaped annuloplasty ring (RSA; n=10), Carpentier-Edwards Physio (PHY; n=11), Edwards IMR ETlogix (ETL; n=11), and GeoForm (GEO; n=12) annuloplasty rings were implanted in a releasable fashion. Four-dimensional marker coordinates were obtained using biplane videofluoroscopy with the ring inserted (ring) and after ring release (control). From marker coordinates, a functional spatio-temporal representation of each annulus was generated through a best fit using 16 piecewise cubic Hermitian splines. Absolute total mitral annular ring strains were calculated from the relative change in length of the tangent vector to the annular curve as strains occurring from control to ring state at end-systole. In addition, average Green-Lagrange strains occurring from control to ring state at end-systole along the annulus were calculated. Absolute total mitral annular ring strains were smallest for COS and greatest for ETL. Strains for RSA, PHY, and GEO were similar. Except for COS in the septal mitral annular segment, all rings induced compressive strains along the entire annulus, with greatest values occurring at the lateral mitral annular segment. Conclusions— In healthy, beating ovine hearts, annuloplasty rings (COS, RSA, PHY, ETL, and GEO) induce compressive strains that are predominate in the lateral annular region, smallest for flexible partial bands (COS) and greatest for an asymmetrical rigid ring type with intrinsic septal-lateral downsizing (ETL). However, the ring type with the most drastic intrinsic septal-lateral downsizing (GEO) introduced strains similar to physiologically shaped rings (RSA and PHY), indicating that ring effects on annular strain profiles cannot be estimated from the degree of septal-lateral downsizing.

[1]  Wolfgang Bothe,et al.  How much septal-lateral mitral annular reduction do you get with new ischemic/functional mitral regurgitation annuloplasty rings? , 2010, The Journal of thoracic and cardiovascular surgery.

[2]  J. Bavaria,et al.  Saddle-shape annuloplasty increases mitral leaflet coaptation after repair for flail posterior leaflet. , 2011, The Annals of thoracic surgery.

[3]  M. Enriquez-Sarano,et al.  Very Long-Term Survival and Durability of Mitral Valve Repair for Mitral Valve Prolapse , 2001, Circulation.

[4]  Joseph H. Gorman,et al.  In Vivo Dynamic Deformation of the Mitral Valve Annulus , 2009, Annals of Biomedical Engineering.

[5]  Julia C. Swanson,et al.  Effects of different annuloplasty rings on anterior mitral leaflet dimensions. , 2010, The Journal of thoracic and cardiovascular surgery.

[6]  C. Duran,et al.  Outcome after mitral valve repair for functional ischemic mitral regurgitation. , 2002, The Journal of heart valve disease.

[7]  Neil B. Ingels,et al.  Characterization of Mitral Valve Annular Dynamics in the Beating Heart , 2011, Annals of Biomedical Engineering.

[8]  A. Gillinov,et al.  Recurrent Mitral Regurgitation Late after Annuloplasty for Ischemic Mitral Regurgitation , 2011, Echocardiography.

[9]  D. C. Miller,et al.  Effects of different annuloplasty ring types on mitral leaflet tenting area during acute myocardial ischemia. , 2011, The Journal of thoracic and cardiovascular surgery.

[10]  O. Alfieri,et al.  The GeoForm annuloplasty ring for the surgical treatment of functional mitral regurgitation in advanced dilated cardiomyopathy. , 2009, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[11]  D. C. Miller,et al.  Experimental and clinical assessment of mitral annular area and dynamics: what are we actually measuring? , 2001, The Annals of thoracic surgery.

[12]  R. Levine,et al.  Saddle-shaped mitral valve annuloplasty rings improve leaflet coaptation geometry. , 2007, The Journal of thoracic and cardiovascular surgery.

[13]  M A Niczyporuk,et al.  Automatic tracking and digitization of multiple radiopaque myocardial markers. , 1991, Computers and biomedical research, an international journal.

[14]  David S. Hirsh,et al.  Real-time 3-dimensional transesophageal echocardiography in the evaluation of post-operative mitral annuloplasty ring and prosthetic valve dehiscence. , 2009, Journal of the American College of Cardiology.

[15]  E. Kuhl,et al.  Mitral Valve Annuloplasty A Quantitative Clinical and Mechanical Comparison of Different Annuloplasty Devices , 2012 .

[16]  D. Adams,et al.  Mitral Valve Repair With Carpentier-McCarthy-Adams IMR ETlogix Annuloplasty Ring for Ischemic Mitral Regurgitation: Early Echocardiographic Results From a Multi-Center Study , 2006, Circulation.

[17]  Serdar Göktepe,et al.  Rigid, Complete Annuloplasty Rings Increase Anterior Mitral Leaflet Strains in the Normal Beating Ovine Heart , 2010, Circulation.

[18]  S. Takanashi,et al.  Mechanisms of recurrent regurgitation after valve repair for prolapsed mitral valve disease. , 2011, The Annals of thoracic surgery.

[19]  J. van der Linden,et al.  Letter by van der Linden et al regarding article, "Effect of clopidogrel premedication in off-pump cardiac surgery: are we forfeiting the benefits of reduced hemorrhagic sequelae?". , 2006, Circulation.

[20]  R. McBane,et al.  Aortic thrombosis as a complication of paroxysmal nocturnal hemoglobinuria. , 2001, Circulation.