Research on the heat transfer model of platen heating surface of 300 MW circulating fluidized bed boilers

Abstract The heat transfer of the platen heating surface of circulating fluidized bed (CFB) boilers is a complex process. Because of technical protection and difficult measurement, at present there is no public calculation method which can be applied to engineering. Three 300 MW CFB boilers in actual operation in different field sites were conducted, the parameters of temperature and pressure at the side of steam and flue gas were measured respectively. Based on the tests at different loads, the effects of solids suspension concentration and average temperature parameters etc. on the heat transfer were investigated, and then the heat transfer coefficient calculation model of platen heating surface at the flue gas side was established, which takes the effects of structure and dimension of platen heating surface, furnace temperature, steam temperature, heat transfer coefficient at the steam side, emissivity of tube wall and fluidization velocity etc. into consideration. The field test data obtained from another 300 MW CFB boiler were used to verify the model. After comparing the calculated results and the values from the actual field test, it is found that the error is lower than 5%, which is within the precision permission range of engineering application. It is indicated that the calculation results using this model agree well with the experimental results on the site, confirming the reliability of this heat transfer model, which means that it can be used to calculate the heat transfer of platen heating surface of 300 MW CFB boiler and can provide reference for design, commissioning, operation of 300 MW CFB boilers.

[1]  Kim Dam-Johansen,et al.  Single-particle behaviour in circulating fluidized beds , 1997 .

[2]  P. Basu,et al.  An investigation into heat transfer in circulating fluidized beds , 1987 .

[3]  Arto Hotta,et al.  Foster Wheeler’s Solutions for Large Scale CFB Boiler Technology: Features and Operational Performance of Łagisza 460 MWe CFB Boiler , 2009 .

[4]  E. N. Sieder,et al.  Heat Transfer and Pressure Drop of Liquids in Tubes , 1936 .

[5]  B. Leckner,et al.  Experimental methods of estimating heat transfer in circulating fluidized bed boilers , 1992 .

[6]  Bie Rushan,et al.  Heat flux profile of the furnace wall of a 300 MWe CFB boiler , 2010 .

[7]  Claes Breitholtz,et al.  Wall average heat transfer in CFB boilers , 2001 .

[8]  J. Armstrong,et al.  A Review of Staggered Array Pin Fin Heat Transfer for Turbine Cooling Applications , 1987 .

[9]  L. Goldstein,et al.  Experiments on the local heat transfer characteristics of a circulating fluidized bed , 2000 .

[10]  J. Grace,et al.  Suspension‐to‐Surface heat transfer in a circulating‐fluidized‐bed combustor , 1989 .

[11]  A. Kolar,et al.  Core heat transfer studies in a circulating fluidized bed , 2002 .

[12]  D. Bai,et al.  Fractal characteristics of gas-solids flow in a circulating fluidized bed , 1997 .

[13]  B. Andersson Effects of bed particle size on heat transfer in circulating fluidized bed boilers , 1996 .

[14]  FURTHER STUDIES ON THE COAL COMBUSTION BEHAVIOR IN THE TANGENTIALLY FIRED BOILER FURNACE , 2001 .

[15]  Jan Erik Johnsson,et al.  Formation and reduction of nitrogen oxides in fluidized-bed combustion☆ , 1994 .

[16]  Junfu Lu,et al.  Method of calculation of heat transfer coefficient of the heater in a circulating fluidized bed furnace , 2002 .

[17]  Xu Zhou,et al.  Thermal-hydraulic analysis of a 600 MW supercritical CFB boiler with low mass flux , 2012 .

[18]  A. P. Baskakov,et al.  Radiative heat transfer in circulating fluidized bed furnaces , 1997 .