On-the-fly Generation of Multiplanar Reformation Images Independent of CT Scanner Type

We propose a system that automatically generates multiplanar reformation (MPR) images on-the-fly, which is independent of computed tomography (CT) scanner type. Triggered by digital imaging communication in medicine (DICOM) Storage Commitment or in a time threshold manner, this system generates MPR images from received thin-section CT data sets with predefined reformation parameters and then sends MPR images to DICOM stations. Users can specify the reformation parameters and the destination of the resulting MPR images for each CT study description. A pilot system was tested for 3 months. From thin-section data sets received from two 16- and one 64-detector-row CT scanners, this system generated MPR images and sent them to the picture archiving and communication system (PACS) without failure or any additional human operation. For 143 test thin-section CT studies (172–4,761 images in each study), the time to store reformatted images (axial and coronal with 5-mm thicknesses and 4-mm intervals) in PACS after the completion of the CT scan ranged from 92 to 1,772 s (mean  SD, 555.1  509.4).

[1]  Kevin McEnery,et al.  Impact of multislice CT on PACS resources. , 2002, Journal of digital imaging.

[2]  Seokyung Hahn,et al.  Computed Tomography Diagnosis of Acute Appendicitis: Advantages of Reviewing Thin-section Datasets using Sliding Slab Average Intensity Projection Technique , 2006, Investigative radiology.

[3]  Michael W Freckleton,et al.  Informatics in radiology (infoRAD): introduction to the language of three-dimensional imaging with multidetector CT. , 2005, Radiographics : a review publication of the Radiological Society of North America, Inc.

[4]  George Wolberg,et al.  Digital image warping , 1990 .

[5]  Kyoung-Sik Cho,et al.  CT angiography for evaluation of living renal donors: comparison of four reconstruction methods. , 2004, AJR. American journal of roentgenology.

[6]  Michael F McNitt-Gray,et al.  AAPM/RSNA Physics Tutorial for Residents: Topics in CT. Radiation dose in CT. , 2002, Radiographics : a review publication of the Radiological Society of North America, Inc.

[7]  Sang Tae Kim,et al.  Managing the CT Data Explosion: Initial Experiences of Archiving Volumetric Datasets in a Mini-PACS , 2005, SPIE Medical Imaging.

[8]  Tracy A Jaffe,et al.  Acute appendicitis: added diagnostic value of coronal reformations from isotropic voxels at multi-detector row CT. , 2005, Radiology.

[9]  K S Pentlow,et al.  Radiation dose in CT. , 1992, Radiographics : a review publication of the Radiological Society of North America, Inc.

[10]  H W Venema,et al.  Petrosal bone: coronal reconstructions from axial spiral CT data obtained with 0.5-mm collimation can replace direct coronal sequential CT scans. , 1999, Radiology.

[11]  K Andoh,et al.  Primary Pulmonary Amyloidosis Mimicking Primary Lung Cancer , 1993, Journal of computer assisted tomography.

[12]  Mathias Prokop,et al.  Multislice CT: technical principles and future trends , 2003, European radiology.

[13]  G D Rubin,et al.  STS-MIP: a new reconstruction technique for CT of the chest. , 1993, Journal of computer assisted tomography.

[14]  Dwayne Phillips,et al.  Image processing in C , 1994 .

[15]  Borut Marincek,et al.  Multidetector-row helical CT: analysis of time management and workflow , 2002, European Radiology.

[16]  G. Rubin,et al.  Data explosion: the challenge of multidetector-row CT. , 2000, European journal of radiology.

[17]  Geoffrey D Rubin,et al.  3-D imaging with MDCT. , 2003, European journal of radiology.

[18]  J. Remy,et al.  Diffuse infiltrative lung disease: clinical value of sliding-thin-slab maximum intensity projection CT scans in the detection of mild micronodular patterns. , 1996, Radiology.

[19]  Dianna D Cody,et al.  AAPM/RSNA physics tutorial for residents: topics in CT. Image processing in CT. , 2002, Radiographics : a review publication of the Radiological Society of North America, Inc.