Getting more early photons with less background: detection rate and signal-to-background improvements in enhanced early photon imaging

With tissue samples less than 1 mm in thickness, optical projection tomography (OPT) has proven to be a very powerful imaging modality that can achieve high spatial resolution images. This high resolution is achieved by collecting the photons with non-significant scattering through 1 mm of tissue, the so-called diffusion limit. But, with samples thicker than 1 mm, scattered photons dominate and the highly resolved images give way to significantly “blurred” images in OPT[1]. However, as increased scattering relates to increased time of travel of the photons so time-domain OPT has been used to only collect the early-arriving photons that have travelled a more direct route through the tissue to reduce detection of scattered photons. Yet very early photons are extremely rare compared to scattered photons. Our recent suggested early photon count rates can be significantly enhanced by running the detector in a “deadtime” regime where the deadtime incurred by early-arriving photons acts as a shutter to later-arriving scattered photons[2]. In this work, we will demonstrate that running in the deadtime also had the unexpected advantage of significantly reducing the number of background photons detected. Proposed approach increases the early photon detection rate by 3-orders-of-magnitude in comparison with conventional approaches in 4-mm thick tissues with 780 nm light while the laser power is far below the level that would significantly damage the tissue. In addition, the signal to background (caused by after pulsing) was improved by 70-fold compared to conventional approaches designed to collect an equal number of early photons.

[1]  S. A. Prahl,et al.  A Monte Carlo model of light propagation in tissue , 1989, Other Conferences.

[2]  Bozena Kaminska,et al.  Image contrast enhancement in angular domain optical imaging of turbid media. , 2008, Optics express.

[3]  K. Tichauer,et al.  Enhanced detection of early photons in time-domain optical imaging by running in the "dead-time" regime. , 2016, Optics letters.

[4]  Otto S. Hoekstra,et al.  Sentinel Node Biopsy in Melanoma Patients: Dynamic Lymphoscintigraphy Followed by Intraoperative Gamma Probe and Vital Dye Guidance , 1997, World Journal of Surgery.

[5]  J. Si,et al.  High contrast ballistic imaging using femtosecond optical Kerr gate of tellurite glass. , 2013, Optics express.

[6]  R. Alfano,et al.  Ballistic 2-D Imaging Through Scattering Walls Using an Ultrafast Optical Kerr Gate , 1991, Science.

[7]  B. Wilson,et al.  Time resolved reflectance and transmittance for the non-invasive measurement of tissue optical properties. , 1989, Applied optics.

[8]  Tayyaba Hasan,et al.  Microscopic lymph node tumor burden quantified by macroscopic dual-tracer molecular imaging , 2014, Nature Medicine.

[9]  A. Jemal,et al.  Global Cancer Statistics , 2011 .

[10]  R. Cubeddu,et al.  Time-gated optical projection tomography. , 2010, Optics letters.

[11]  Vasilis Ntziachristos,et al.  Early photon tomography allows fluorescence detection of lung carcinomas and disease progression in mice in vivo , 2008, Proceedings of the National Academy of Sciences.

[12]  S R Arridge,et al.  Recent advances in diffuse optical imaging , 2005, Physics in medicine and biology.

[13]  David A Boas,et al.  Monte Carlo simulation of photon migration in 3D turbid media accelerated by graphics processing units. , 2009, Optics express.

[14]  Herwig Kogelnik,et al.  Laser beams and resonators , 1966 .

[15]  Rinaldo Cubeddu,et al.  Time-Gated Optical Projection Tomography Allows Visualization of Adult Zebrafish Internal Structures , 2012, PloS one.

[16]  Donald L Weaver,et al.  Pathology evaluation of sentinel lymph nodes in breast cancer: protocol recommendations and rationale , 2010, Modern Pathology.

[17]  S. Arridge,et al.  Optical tomography: forward and inverse problems , 2009, 0907.2586.

[18]  V. V. Tuchin Light scattering study of tissues , 1997 .