Study of a semi-active stiffness damper under various earthquake inputs
暂无分享,去创建一个
Semi-active stiffness damper (SASD) is one of many semi-active control systems with the capability to mitigate the dynamic response using only a small amount of external power. The system consists of a hydraulic damper connected to the bracing frame in a selected story unit. In this paper, study of a SASD in two building models of five-stories under four benchmark earthquake records is reported. The purpose of this study is to evaluate the effectiveness of the control system against structure type and varying earthquake inputs. Various control laws are chosen to work with SASD, such as: resetting control, switching control, linear quadratic regulator (LQR) and modified LQR, and the results are compared with no control and passive control cases. Numerical results show that the use of a SASD is effective in reducing seismic responses. Control effectiveness is dependent on the type of structure and earthquake excitation. Passive control is less effective than other control cases as expected. Resetting control, switching control and LQR generally perform similarly in response reduction. While modified LQR is more efficient and robust compared with other control algorithms. Copyright © 2002 John Wiley & Sons, Ltd.
[1] Takuji Kobori,et al. Actual seismic response controlled building with semi-active damper system , 1999 .
[2] Jann N. Yang,et al. RESETTING SEMIACTIVE STIFFNESS DAMPER FOR SEISMIC RESPONSE CONTROL , 2000 .
[3] Hung T. Nguyen,et al. Effectiveness of semi-active stiffness damper in a five-storey model , 2001 .
[4] J. N. Yang,et al. A semi-active stiffness damper for vibration control of civil engineering structures , 1999 .