Studies of the 'hook' effect in the one-step sandwich immunoassay.

The one-step sandwich immunoassay is increasingly replacing the traditional two-step immunoassay due to obvious advantages such as assay speed. However, the one-step sandwich immunoassay suffers from the 'hook' effect irrespective of the analyte characteristics. The 'hook' effect is dependent primarily on the analyte concentration. Three different model analytes, human growth hormone (hGH), the dimeric form of hGH (D-hGH, having a discrete number of repeating epitopes) and ferritin (multiple epitopes) having different immunological properties have been employed in studies of the one-step sandwich immunoassay. The characteristics of each of the model analytes offer new insights into general guidelines for assay procedures. These guidelines permit rapid optimization of assay conditions for an immunoassay without a priori knowledge of the immunological characteristics of the antibody or antigen. Both experimental and theoretical data show several instances where high capacity solid-phase antibodies can effectively shift the 'hook' to relatively higher analyte concentrations. The effect of the concentration of labeled antibody on assay response was examined theoretically.

[1]  J. F. Myrtle More on "hook effects" in immunometric assays for prostate-specific antigen. , 1989, Clinical chemistry.

[2]  J. Guesdon,et al.  Solid-phase sandwich enzyme immunoassays of human chorionic gonadotropin using monoclonal antibodies. , 1985, Journal of immunological methods.

[3]  P. Fernlund,et al.  Immunoradiometric assay of sex-hormone binding globulin with use of two different monoclonal antibodies. , 1986, Clinical chemistry.

[4]  W. Moyle,et al.  Further characterization of cooperative interactions of monoclonal antibodies. , 1983, Journal of immunology.

[5]  I. Vermes,et al.  Interpretations of five monoclonal immunoassays of lutropin and follitropin: effects of normalization with WHO standard. , 1991, Clinical chemistry.

[6]  G. S. Wilson,et al.  Studies of the low dose 'hook' effect in a competitive homogeneous immunoassay. , 1992, Journal of immunological methods.

[7]  M. Khosravi Shifting the "hook effect" in one-step immunometric assays. , 1990, Clinical chemistry.

[8]  M. Worwood,et al.  Antigen Binding in the Two-Site Immunoradiometric Assay for Serum Ferritin: The Nature of the Hook Effect , 1984, Annals of clinical biochemistry.

[9]  R. Bartholomew,et al.  Monoclonal antibodies in clinical immunology. , 1981, Clinical chemistry.

[10]  P. Garcia‐Webb,et al.  High-dose "hook" effect in measurement of somatotropin by two-site immunoradiometric assay. , 1986, Clinical chemistry.

[11]  B. Pau,et al.  Two-site immunoenzymometric assay for the 52-kDa cathepsin D in cytosols of breast cancer tissues. , 1989, Clinical chemistry.

[12]  B. Wolf,et al.  More on "hook effects" in immunometric assays for prostate-specific antigen. , 1989, Clinical chemistry.

[13]  M L Yarmush,et al.  Dissociation kinetics of antigen-antibody interactions: studies on a panel of anti-albumin monoclonal antibodies. , 1989, Molecular immunology.

[14]  A. Khagani,et al.  The "hook effect": high concentrations of prostate-specific antigen giving artifactually low values on one-step immunoassay. , 1989 .

[15]  D. Ooi,et al.  "High-dose hook effect" in IRMA-Count PSA assay of prostate-specific antigen. , 1991, Clinical chemistry.

[16]  C. Hales,et al.  Labelled Antibodies and Immunological Assay Systems , 1968, Nature.

[17]  R. Ng,et al.  Three commercial methods for serum ferritin compared and the high-dose "hook effect" eliminated. , 1983, Clinical chemistry.

[18]  D R Turner,et al.  Reappraisal of the causes of the "hook effect" in two-site immunoradiometric assays. , 1982, Analytical biochemistry.

[19]  E. Diamandis,et al.  Immunofluorometry of choriogonadotropin by time-resolved fluorescence spectroscopy, with a new europium chelate as label. , 1987, Clinical chemistry.

[20]  J. Gosling A decade of development in immunoassay methodology. , 1990, Clinical chemistry.

[21]  G. S. Wilson,et al.  Multiple epitope interactions in the two-step sandwich immunoassay. , 1992, Journal of immunological methods.

[22]  W. Smith,et al.  Practical automation and interpretation of quantitative assays of antibodies to therapeutic proteins, illustrated with human growth hormone. , 1989, Clinical Chemistry.

[23]  G. Brem,et al.  "High-dose hook effect" as a pitfall in quantifying transgene expression in metallothionein-human growth hormone (MT-hGH) transgenic mice. , 1991, Clinical chemistry.

[24]  D. Anderson,et al.  A circular antibody-antigen complex is responsible for increased affinity shown by mixtures of monoclonal antibodies to human chorionic gonadotropin. , 1983, Journal of immunology.

[25]  GW Becker,et al.  Chemical, Physical, and Biological Characterization of a Dimeric form of Biosynthetic Human Growth Hormone , 1987, Biotechnology and applied biochemistry.

[26]  G. Parsons,et al.  Use of a solid-state multihead gamma counter in a second-generation system for solid-phase immunoassay. , 1983, Clinical chemistry.

[27]  B. Wolf,et al.  Extremely high values of prostate-specific antigen in patients with adenocarcinoma of the prostate; demonstration of the "hook effect". , 1988, Clinical chemistry.

[28]  D. Klingmüller,et al.  "Hook-effect" in a patient with a gonadotropin-secreting tumor. , 1990, Clinical chemistry.

[29]  J. W. Osborne,et al.  The adsorptive characteristics of proteins for polystyrene and their significance in solid-phase imunoassays. , 1980, Analytical biochemistry.

[30]  P. Gnocchi,et al.  A monoclonal-based, two-site enzyme immunoassay of human insulin. , 1987, Journal of immunological methods.

[31]  J. M. Brooks,et al.  Elimination of "hook-effect" in two-site immunoradiometric assays by kinetic rate analysis. , 1984, Clinical chemistry.

[32]  I. M. Klotz,et al.  Protein affinities for small molecules: conceptions and misconceptions. , 1979, Archives of biochemistry and biophysics.