Volume-of-interest (VOI) imaging in C-arm flat-detector CT for high image quality at reduced dose.

PURPOSE A novel method for flat-detector computed tomography was developed to enable volume-of-interest (VOI) imaging at high resolution, low noise, and reduced dose. For this, a full low-dose overview (OV) scan and a local high-dose scan of a VOI are combined. METHODS The first scan yields an overview of the whole object and enables the selection of an arbitrary VOI. The second scan of that VOI assures high image quality within the interesting volume. The combination of the two consecutive scans is based on a forward projection of the reconstructed OV volume that was registered to the VOI. The artificial projection data of the OV scan are combined with the measured VOI data in the raw data domain. Different projection values are matched by an appropriate transformation and weighting. The reconstruction is performed with a standard Feldkamp-type algorithm. In simulations, the combination of OV scan and VOI scan was investigated on a mathematically described phantom. In measurements, spatial resolution and noise were evaluated with image quality phantoms. Modulation transfer functions and noise values were calculated. Measurements of an anthropomorphic head phantom were used to validate the proposed method for realistic applications, e.g., imaging stents. In Monte Carlo simulations, 3D dose distributions were calculated and dose values were assessed quantitatively. RESULTS By the proposed combination method, an image is generated which covers the whole object and provides the VOI at high image quality. In the OV image, a resolution of 0.7 lp/mm (line pairs per millimeter) and noise of 63.5 HU were determined. Inside the VOI, resolution was increased to 2.4 lp/mm and noise was decreased to 18.7 HU. For the performed measurements, the cumulative dose was significantly reduced in comparison to conventional scans by up to 93%. The dose of a high-quality scan, for example, was reduced from 97 to less than 7 mGy, while keeping image quality constant within the VOI. CONCLUSIONS The proposed VOI application with two scans is an effective way to ensure high image quality within the VOI while simultaneously reducing the cumulative patient dose.

[1]  F. Noo,et al.  A two-step Hilbert transform method for 2D image reconstruction. , 2004, Physics in medicine and biology.

[2]  Günter Lauritsch,et al.  Truncation correction for oblique filtering lines. , 2008, Medical physics.

[3]  Willi A. Kalender,et al.  Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography , 2008, European Radiology.

[4]  W A Kalender,et al.  Neuroradiologic Applications with Routine C-arm Flat Panel Detector CT: Evaluation of Patient Dose Measurements , 2008, American Journal of Neuroradiology.

[5]  Guy Marchal,et al.  Multimodality image registration by maximization of mutual information , 1997, IEEE Transactions on Medical Imaging.

[6]  P. Joseph An Improved Algorithm for Reprojecting Rays through Pixel Images , 1982 .

[7]  Xiaochuan Pan,et al.  Region-of-interest image reconstruction with intensity weighting in circular cone-beam CT for image-guided radiation therapy. , 2009, Medical physics.

[8]  Tianpeng Wang,et al.  Dual resolution cone beam breast CT: a feasibility study. , 2009, Medical physics.

[9]  Gustavo H Olivera,et al.  Methods for improving limited field-of-view radiotherapy reconstructions using imperfect a priori images. , 2002, Medical physics.

[10]  Hengyong Yu,et al.  Compressed sensing based interior tomography , 2009, Physics in medicine and biology.

[11]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[12]  J H Siewerdsen,et al.  Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype. , 2006, Medical physics.

[13]  Xiaochuan Pan,et al.  Region-of-interest image reconstruction in circular cone-beam microCT. , 2007, Medical physics.

[14]  Anne Rougee,et al.  Geometrical calibration for 3D x-ray imaging , 1993, Medical Imaging.

[15]  M. Kachelriess,et al.  Reconstruction from truncated projections in CT using adaptive detruncation , 2005, European Radiology.

[16]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[17]  Willi A Kalender,et al.  Concepts for dose determination in flat-detector CT , 2008, Physics in medicine and biology.

[18]  Jürgen Weese,et al.  Projection extension for region of interest imaging in cone-beam CT. , 2005, Academic radiology.

[19]  Lingyun Chen,et al.  Reduction in x-ray scatter and radiation dose for volume-of-interest (VOI) cone-beam breast CT--a phantom study. , 2009, Physics in medicine and biology.

[20]  S. Umeyama,et al.  Least-Squares Estimation of Transformation Parameters Between Two Point Patterns , 1991, IEEE Trans. Pattern Anal. Mach. Intell..

[21]  Kenneth R Hoffmann,et al.  Filtered region of interest cone-beam rotational angiography. , 2010, Medical physics.

[22]  B. Wilson,et al.  Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery. , 2005, Medical physics.

[23]  Lingyun Chen,et al.  Feasibility of volume-of-interest (VOI) scanning technique in cone beam breast CT--a preliminary study. , 2008, Medical physics.

[24]  Lingyun Chen,et al.  Feasibility of volume-of-interest (VOI) scanning technique in cone beam breast CT-a preliminary study. , 2008, Medical physics.

[25]  Jiang Hsieh,et al.  Resolution and noise trade-off analysis for volumetric CT. , 2007, Medical physics.

[26]  D. Parker Optimal short scan convolution reconstruction for fan beam CT , 1982 .

[27]  W. Kalender,et al.  Flat-detector computed tomography (FD-CT) , 2007, European Radiology.

[28]  J. Hsieh,et al.  A novel reconstruction algorithm to extend the CT scan field-of-view. , 2004, Medical physics.