Numerical Simulation of a 600 MW Utility Boiler with Different Tangential Arrangements of Burners
暂无分享,去创建一个
Linbo Yan | Boshu He | Fang Yao | Rui Yang | Xiaohui Pei | Chaojun Wang | Jingge Song
[1] R. A. Wessel,et al. Numerical Model for Predicting Performance of Three-Dimensional Pulverized-Fuel Fired Furnaces , 1988 .
[2] J. L. T. Azevedo,et al. 3-D numerical model for predicting NOx emissions from an industrial pulverized coal combustor , 1994 .
[3] Alexander L. Brown,et al. Soot in coal combustion systems , 1997 .
[4] Tan Houzhan. THE EXPERIMENT STUDY OF HEAT FLUX DISTRIBUTION IN WALL-TANGENTIALLY FLAME , 2000 .
[6] NUMERICAL STUDY ON THE CONTRARY MODES OF AIR JETS IN A LARGE FURNACE , 2001 .
[7] Mohamed Pourkashanian,et al. Modelling coal combustion: the current position , 2002 .
[8] Jean-Luc Harion,et al. Investigation of the flow, combustion, heat-transfer and emissions from a 609MW utility tangentially fired pulverized-coal boiler , 2002 .
[9] Lasse Rosendahl,et al. Further study of the gas temperature deviation in large-scale tangentially coal-fired boilers☆ ☆ , 2003 .
[10] R. Kurose,et al. Numerical analysis of pulverized coal combustion characteristics using advanced low-NOx burner , 2004 .
[11] Boshu He,et al. Numerical study of the optimum counter-flow mode of air jets in a large utility furnace , 2004 .
[12] Numerical simulation of combustion and nitrogen oxides generation process in tangentially fired furnace , 2004 .
[13] Cen Ke-fa. NUMERICAL SIMULATION OF COMBUSTION PROCESS IN A 200MW TANGENTIALLY FIRED FURNACE TO STUDY FURNACE RECONSTRUCTION , 2005 .
[14] Rui Sun. NUMERICAL SIMULATION ON PULVERIZED COAL COMBUSTION PROCESS IN A TANGENTIAL FIRING FURNACE , 2006 .
[15] He Bo-sh. Numerical Diagnoses to the Reheater Panel Overheating of No.3 Boiler of Dagang Power Plant , 2007 .
[16] Boshu He,et al. Computational fluid dynamics based retrofits to reheater panel overheating of No. 3 boiler of Dagang Power Plant , 2007 .
[17] Chang Nyung Kim,et al. Numerical investigation on the flow, combustion and NOx emission characteristics in a 500 MWe tangentially fired pulverized-coal boiler , 2009 .
[18] Jamal Naser,et al. Aerodynamics of an isolated slot-burner from a tangentially-fired boiler , 2009 .
[19] Xiang Daguang. DESIGN FEATURES OF LIGNITE-COAL FIRED LARGE-SCALE UTILITY BOILERS , 2010 .
[20] Panagiotis Grammelis,et al. Numerical investigation of the oxy-fuel combustion in large scale boilers adopting the ECO-Scrub technology , 2011 .
[21] He Bo-shu. Modification of a 600 MW Coal-fired Boiler Due to an Excessively Low Temperature of the Secondary Steam and Its Implementation Effectiveness , 2011 .
[22] Si Jinru. Numerical Simulation of Wall Arrangement Burners at Different Swing Levels , 2011 .
[23] Shien Hui,et al. Study of optimal pulverized coal concentration in a four-wall tangentially fired furnace , 2011 .