How do I perform a lumbar puncture and analyze the results to diagnose bacterial meningitis?

CONTEXT Diagnostic lumbar punctures (LPs), commonly used to rule out meningitis, are associated with adverse events. OBJECTIVE To systematically review the evidence about diagnostic LP techniques that may decrease the risk of adverse events and the evidence about test accuracy of cerebrospinal fluid (CSF) analysis in adult patients with suspected bacterial meningitis. DATA SOURCES We searched the Cochrane Library, MEDLINE (using Ovid and PubMed) from 1966 to January 2006 and EMBASE from 1980 to January 2006 without language restrictions to identify relevant studies and identified others from the bibliographies of retrieved articles. STUDY SELECTION We included randomized trials of patients aged 18 years or older undergoing interventions to facilitate a successful diagnostic LP or to potentially reduce adverse events. Studies assessing the accuracy of biochemical analysis of the CSF for possible bacterial meningitis were also identified. DATA EXTRACTION Two investigators independently appraised study quality and extracted relevant data. For studies of the LP technique, data on the intervention and the outcome were extracted. For studies of the laboratory diagnosis of bacterial meningitis, data on the reference standard and test accuracy were extracted. DATA SYNTHESIS We found 15 randomized trials. A random-effects model was used for quantitative synthesis. Five studies of 587 patients compared atraumatic needles with standard needles and found a nonsignificant decrease in the odds of headache with an atraumatic needle (absolute risk reduction [ARR], 12.3%; 95% confidence interval [CI], -1.72% to 26.2%). Reinsertion of the stylet before needle removal decreased the risk of headache (ARR, 11.3%; 95% CI, 6.50%-16.2%). The combined results from 4 studies of 717 patients showed a nonsignificant decrease in headache in patients who were mobilized after LP (ARR, 2.9%; 95% CI, -3.4 to 9.3%). Four studies on the accuracy of biochemical analysis of CSF in patients with suspected meningitis met inclusion criteria. A CSF-blood glucose ratio of 0.4 or less (likelihood ratio [LR], 18; 95% CI, 12-27]), CSF white blood cell count of 500/muL or higher (LR, 15; 95% CI, 10-22), and CSF lactate level of 31.53 mg/dL or more (> or =3.5 mmol/L; LR, 21; 95% CI, 14-32) accurately diagnosed bacterial meningitis. CONCLUSIONS These data suggest that small-gauge, atraumatic needles may decrease the risk of headache after diagnostic LP. Reinsertion of the stylet before needle removal should occur and patients do not require bed rest after the procedure. Future research should focus on evaluating interventions to optimize the success of a diagnostic LP and to enhance training in procedural skills.

[1]  J. Meiring,et al.  Lumbar puncture: Anatomical review of a clinical skill , 2004, Clinical anatomy.

[2]  D. Burn,et al.  Is bed rest useful after diagnostic lumbar puncture? , 1992, Postgraduate medical journal.

[3]  B. Woolf ON ESTIMATING THE RELATION BETWEEN BLOOD GROUP AND DISEASE , 1955, Annals of human genetics.

[4]  B Suñé,et al.  [Lumbar puncture]. , 1982, Revista de enfermeria.

[5]  T. Marrie,et al.  Evaluation of cerebrospinal fluid lactic acid levels as an aid in differential diagnosis of bacterial and viral meningitis in adults , 1980, Journal of clinical microbiology.

[6]  J M Pearce,et al.  Procedures in practice. Lumbar puncture. , 1980, British medical journal.

[7]  J. Edlow,et al.  Incidence of traumatic lumbar puncture. , 2003, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[8]  T. Brandt,et al.  “Atraumatic” Sprotte needle reduces the incidence of post-lumbar puncture headaches , 2001, Neurology.

[9]  Jeroan J Allison,et al.  Identifying achievable benchmarks of care: concepts and methodology. , 1998, International journal for quality in health care : journal of the International Society for Quality in Health Care.

[10]  J. Pépin,et al.  No Significant Effect of An “Atraumatic” Needle on Incidence of Post-Lumbar Puncture Headache or Traumatic Tap , 1993, Cephalalgia : an international journal of headache.

[11]  W. Shestak,et al.  Optimal patient position for lumbar puncture, measured by ultrasonography , 2004, Emergency Radiology.

[12]  D. Goodin,et al.  Assessment: Prevention of post–lumbar puncture headaches , 2000, Neurology.

[13]  Ames,et al.  Computed tomography of the head before lumbar puncture in adults with suspected meningitis. , 2001, The New England journal of medicine.

[14]  R. Ruff,et al.  Complications of lumbar puncture followed by anticoagulation. , 1981, Stroke.

[15]  J. Viel,et al.  Prospective Validation of a Diagnosis Model as an Aid to Therapeutic Decision-Making in Acute Meningitis , 2000, European Journal of Clinical Microbiology and Infectious Diseases.

[16]  R. Sulkava,et al.  Duration of Postural Headache After Lumbar Puncture: Effect of Needle Size , 1986, Headache.

[17]  C. Vedeler,et al.  Post‐dural puncture related complications after diagnostic lumbar puncture, myelography and spinal anaesthesia , 1998, Acta neurologica Scandinavica.

[18]  A. Myerson,et al.  EFFECTS OF ALTERATIONS IN POSTURE ON THE CEREBROSPINAL FLUID PRESSURE , 1935 .

[19]  D. Marmer,et al.  Leukocyte survival in cerebrospinal fluid , 1986, Journal of clinical microbiology.

[20]  H. V. Crevel,et al.  Lumbar Puncture Headache: Controlled Study on the Preventive Effect of 24 Hoursʼ Bed Rest , 1982 .

[21]  M. Serpell,et al.  Prevention of headache after lumbar puncture: questionnaire survey of neurologists and neurosurgeons in United Kingdom: , 1998, BMJ.

[22]  D. Simel,et al.  Cranial computed tomography before lumbar puncture: a prospective clinical evaluation. , 1999, Archives of internal medicine.

[23]  D. Forman,et al.  Laboratory analysis of cerebrospinal fluid. , 1994, Clinical laboratory science : journal of the American Society for Medical Technology.

[24]  J. Stevens,et al.  Post‐lumbar puncture headaches , 1992, Neurology.

[25]  R. P. Kleyweg,et al.  Significant Reduction in Post-Lumbar Puncture Headache Using an Atraumatic Needle. A Double-Blind, Controlled Clinical Trial , 1998, Cephalalgia : an international journal of headache.

[26]  T. Brandt,et al.  Incidence of post-lumbar puncture headache is independent of daily fluid intake , 2004, European archives of psychiatry and neurological sciences.

[27]  H. Reichmann,et al.  Atraumatic needle reduces the incidence of post-lumbar puncture syndrome , 1994, Journal of Neurology.

[28]  B. Wasilauskas,et al.  Determination of bacterial meningitis: a retrospective study of 80 cerebrospinal fluid specimens evaluated by four in vitro methods , 1982, Journal of clinical microbiology.

[29]  F. Harrell,et al.  Differential diagnosis of acute meningitis. An analysis of the predictive value of initial observations. , 1989, JAMA.

[30]  C. Hartigan,et al.  Cranial computed tomography before lumbar puncture. , 2000, Archives of internal medicine.

[31]  L. Hansson,et al.  Value of cerebrospinal fluid analysis in the differential diagnosis of meningitis: A study in 710 patients with suspected central nervous system infection , 1988, European Journal of Clinical Microbiology and Infectious Diseases.

[32]  D. Thys,et al.  Use of Atraumatic Spinal Needles Among Neurologists in the United States , 2001, Headache.

[33]  R. Laureno,et al.  Precautions for lumbar puncture: A survey of neurologic educators , 1999, Neurology.

[34]  D. Safranek Post-lumbar puncture headaches: Experience in 501 consecutive procedures , 1993 .

[35]  A. Bier Versuche über Cocainisirung des Rückenmarkes , 1899, Deutsche Zeitschrift für Chirurgie.

[36]  R. Evans Complications of lumbar puncture. , 1998, Neurologic clinics.

[37]  K. Muir,et al.  Randomised controlled trial of atraumatic versus standard needles for diagnostic lumbar puncture , 2000, BMJ : British Medical Journal.

[38]  The validity of Spanos' and Hoen's models for differential diagnosis of meningitis , 1996, European Journal of Clinical Microbiology and Infectious Diseases.

[39]  P. Nordmann,et al.  Accuracy of clinical presentation for differentiating bacterial from viral meningitis in adults: a multivariate approach , 2005, Intensive Care Medicine.

[40]  A. Muuronen,et al.  Prolonged impairment in activities of daily living due to postdural puncture headache after diagnostic lumbar puncture , 1998, Anaesthesia.

[41]  C. Vedeler,et al.  Complications after LP related to needle type: pencil‐point versus Quincke , 2001, Acta neurologica Scandinavica.

[42]  Braune Hj,et al.  A prospective double‐blind clinical trial, comparing the sharp Quincke needle (22G) with an “atraumatic” needle (22G) in the induction of post‐lumbar puncture headache , 1992, Acta neurologica Scandinavica.

[43]  P. Gorman,et al.  A prototype haptic lumbar puncture simulator. , 2000, Studies in health technology and informatics.

[44]  H. V. Crevel,et al.  LUMBAR PUNCTURE HEADACHE: CONTROLLED STUDY ON THE PREVENTIVE EFFECT OF 24 HOURS' BED REST , 1981, The Lancet.

[45]  C. Ogilvy,et al.  Fluoroscopy-guided lumbar puncture: decreased frequency of traumatic tap and implications for the assessment of CT-negative acute subarachnoid hemorrhage. , 2001, AJNR. American journal of neuroradiology.

[46]  K Moorthy,et al.  Validation of a web-based training tool for lumbar puncture. , 2003, Studies in health technology and informatics.

[47]  T. Brandt,et al.  Is obligatory bed rest after lumbar puncture obsolete? , 2004, European archives of psychiatry and neurological sciences.

[48]  W. Henderson,et al.  A RANDOMIZED, DOUBLE‐BLIND CLINICAL TRIAL COMPARING THE 22 VERSUS 26 GAUGE NEEDLE IN THE PRODUCTION OF THE POST‐LUMBAR PUNCTURE SYNDROME IN NORMAL INDIVIDUALS , 1972, Headache.

[49]  M. Young,et al.  Validation of a clinical prediction rule for the differential diagnosis of acute meningitis , 2007, Journal of General Internal Medicine.

[50]  L. Jeyaseelan,et al.  Post lumbar puncture headache: is bed rest essential? , 1998, Journal of Association of Physicians of India.

[51]  J. Viel,et al.  Multivariate approach to differential diagnosis of acute meningitis , 1995, European Journal of Clinical Microbiology and Infectious Diseases.

[52]  G H Guyatt,et al.  Users' guides to the medical literature: XXII: how to use articles about clinical decision rules. Evidence-Based Medicine Working Group. , 2000, JAMA.

[53]  R. Komorowski,et al.  Comparison of cerebrospinal fluid C-reactive protein and lactate for diagnosis of meningitis , 1986, Journal of clinical microbiology.

[54]  Queckenstedt Zur Diagnose der Rückenmarkskompression , 1916, Deutsche Zeitschrift für Nervenheilkunde.

[55]  T. Brandt,et al.  Should one reinsert the stylet during lumbar puncture? , 1997, The New England journal of medicine.

[56]  S. Vilming,et al.  Post-Lumbar-Puncture Headache: The Significance of Body Posture: A Controlled Study of 300 Patients , 1988, Cephalalgia : an international journal of headache.

[57]  H. Bríem,et al.  Comparison between cerebrospinal fluid concentrations of glucose, total protein, chloride, lactate, and total amino acids for the differential diagnosis of patients with meningitis. , 1983, Scandinavian journal of infectious diseases.

[58]  J. Kelly,et al.  The effect of lower-extremity position on cerebrospinal fluid pressures. , 2001, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[59]  B. Neundörfer,et al.  Post-Lumbar Puncture Headache: Experiences With Sprotte's Atraumatic Needle , 1992, Cephalalgia : an international journal of headache.

[60]  J. Conly,et al.  Cerebrospinal fluid as a diagnostic body fluid. , 1983, The American journal of medicine.

[61]  A. Smith,et al.  High acceptability and low morbidity of diagnostic lumbar puncture in elderly subjects of mixed cognitive status , 1995, Acta neurologica Scandinavica.

[62]  S. Vavricka,et al.  Safety of lumbar puncture for adults with acute leukemia and restrictive prophylactic platelet transfusion , 2003, Annals of Hematology.

[63]  C. Warlow,et al.  Failure of postural manoeuvres to prevent lumbar puncture headache. , 1982, Journal of neurology, neurosurgery, and psychiatry.

[64]  D. Cook,et al.  Does this adult patient have acute meningitis , 1999 .

[65]  C. Sudlow,et al.  Posture and fluids for preventing post-dural puncture headache. , 2002, The Cochrane database of systematic reviews.

[66]  C. Handler,et al.  Posture and Lumbar Puncture Headache: A Controlled Trial in 50 Patients , 1982, Journal of the Royal Society of Medicine.

[67]  H. Reichmann,et al.  "Atraumatic" Sprotte needle reduces the incidence of post-lumbar puncture headaches. , 2002, Neurology.

[68]  R. Evans,et al.  Addendum to assessment: Prevention of post–lumbar puncture headaches , 2005, Neurology.

[69]  T. Brandt,et al.  Incidence of post-lumbar puncture syndrome reduced by reinserting the stylet: a randomized prospective study of 600 patients , 1998, Journal of Neurology.

[70]  D. Musher,et al.  Microscopic Examination and Broth Culture of Cerebrospinal Fluid in Diagnosis of Meningitis , 1998, Journal of Clinical Microbiology.

[71]  Ralph Gonzales,et al.  Procedural experience and comfort level in internal medicine trainees , 2000, Journal of General Internal Medicine.

[72]  G. Perkin,et al.  POSTURE AND HEADACHE AFTER LUMBAR PUNCTURE , 1980, The Lancet.