Evaluation of passenger health risk assessment of sustainable indoor air quality monitoring in metro systems based on a non-Gaussian dynamic sensor validation method.

Sensor faults in metro systems provide incorrect information to indoor air quality (IAQ) ventilation systems, resulting in the miss-operation of ventilation systems and adverse effects on passenger health. In this study, a new sensor validation method is proposed to (1) detect, identify and repair sensor faults and (2) evaluate the influence of sensor reliability on passenger health risk. To address the dynamic non-Gaussianity problem of IAQ data, dynamic independent component analysis (DICA) is used. To detect and identify sensor faults, the DICA-based squared prediction error and sensor validity index are used, respectively. To restore the faults to normal measurements, a DICA-based iterative reconstruction algorithm is proposed. The comprehensive indoor air-quality index (CIAI) that evaluates the influence of the current IAQ on passenger health is then compared using the faulty and reconstructed IAQ data sets. Experimental results from a metro station showed that the DICA-based method can produce an improved IAQ level in the metro station and reduce passenger health risk since it more accurately validates sensor faults than do conventional methods.

[1]  In-Beum Lee,et al.  Variable reconstruction and sensor fault identification using canonical variate analysis , 2006 .

[2]  Christos Georgakis,et al.  Disturbance detection and isolation by dynamic principal component analysis , 1995 .

[3]  O. Alfano,et al.  A methodology for modeling photocatalytic reactors for indoor pollution control using previously estimated kinetic parameters. , 2012, Journal of hazardous materials.

[4]  Jeong Tai Kim,et al.  Monitoring and prediction of indoor air quality (IAQ) in subway or metro systems using season dependent models , 2012 .

[5]  Andrew Kusiak,et al.  Prediction of Influent Flow Rate: Data-Mining Approach , 2013 .

[6]  Peder Wolkoff Indoor air pollutants in office environments: assessment of comfort, health, and performance. , 2013, International journal of hygiene and environmental health.

[7]  M. Kampa,et al.  Human health effects of air pollution. , 2008, Environmental pollution.

[8]  B H Jun,et al.  Fault detection using dynamic time warping (DTW) algorithm and discriminant analysis for swine wastewater treatment. , 2011, Journal of hazardous materials.

[9]  Fu Xiao,et al.  A diagnostic tool for online sensor health monitoring in air-conditioning systems , 2006 .

[10]  ChangKyoo Yoo,et al.  Sensor fault identification and reconstruction of indoor air quality (IAQ) data using a multivariate non-Gaussian model in underground building space , 2013 .

[11]  ChangKyoo Yoo,et al.  Statistical monitoring of dynamic processes based on dynamic independent component analysis , 2004 .

[12]  ChangKyoo Yoo,et al.  Statistical process monitoring with independent component analysis , 2004 .

[13]  P A Vanrolleghem,et al.  Dynamic monitoring system for full-scale wastewater treatment plants. , 2004, Water science and technology : a journal of the International Association on Water Pollution Research.

[14]  Ki-Hyun Kim,et al.  A review of diseases associated with household air pollution due to the use of biomass fuels. , 2011, Journal of hazardous materials.

[15]  ChangKyoo Yoo,et al.  A real-time monitoring and assessment method for calculation of total amounts of indoor air pollutants emitted in subway stations , 2012, Journal of the Air & Waste Management Association.

[16]  ChangKyoo Yoo,et al.  Sensor Validation for Monitoring Indoor Air Quality in a Subway Station , 2012 .

[17]  ChangKyoo Yoo,et al.  On-line monitoring of batch processes using multiway independent component analysis , 2004 .

[18]  D. Connell,et al.  Health risk characterisation for environmental pollutants with a new concept of overall risk probability. , 2011, Journal of hazardous materials.

[19]  Jeong Tai Kim,et al.  Predictive monitoring and diagnosis of periodic air pollution in a subway station. , 2010, Journal of hazardous materials.

[20]  D. Moschandreas,et al.  Modeling daily variation of trihalomethane compounds in drinking water system, Houston, Texas. , 2008, Journal of hazardous materials.

[21]  Douglas C. Montgomery,et al.  Statistical quality control : a modern introduction , 2009 .

[22]  M Sam Mannan,et al.  Sensor fault diagnosis for nonlinear processes with parametric uncertainties. , 2006, Journal of hazardous materials.

[23]  S. Joe Qin,et al.  Joint diagnosis of process and sensor faults using principal component analysis , 1998 .

[24]  K B Hoddinott,et al.  The use of environmental risk assessment methodologies for an indoor air quality investigation. , 2000, Chemosphere.

[25]  ChangKyoo Yoo,et al.  Online monitoring and interpretation of periodic diurnal and seasonal variations of indoor air pollutants in a subway station using parallel factor analysis (PARAFAC) , 2014 .

[26]  ChangKyoo Yoo,et al.  Multi-objective optimization of indoor air quality control and energy consumption minimization in a subway ventilation system , 2013 .

[27]  Shohei Yamashita,et al.  A simple method for screening emission sources of carbonyl compounds in indoor air. , 2010, Journal of hazardous materials.

[28]  S. Joe Qin,et al.  Reconstruction-Based Fault Identification Using a Combined Index , 2001 .

[29]  Youming Chen,et al.  Sensor validation and reconstruction for building central chilling systems based on principal component analysis , 2004 .

[30]  Weihua Li,et al.  Detection, identification, and reconstruction of faulty sensors with maximized sensitivity , 1999 .

[31]  Guillermo Heredia,et al.  Sensor and actuator fault detection in small autonomous helicopters , 2008 .

[32]  L. T. Wong,et al.  An evaluation model for indoor environmental quality (IEQ) acceptance in residential buildings , 2009 .

[33]  Youming Chen,et al.  Fault detection, diagnosis and data recovery for a real building heating/cooling billing system , 2010 .

[34]  Wing-tat Hung,et al.  Interpretation of air quality in relation to monitoring station's surroundings , 2009 .

[35]  In-Beum Lee,et al.  Sensor fault identification based on time-lagged PCA in dynamic processes , 2004 .