Sizing and cost estimation methodology for stand-alone residential PV power system

This paper investigates the sizing and costing methodology for a stand-alone photovoltaic (SAPV) power system based on the number of sunshine hours available in the world. The sizing and costing of the PV system for the electrical load of 3.65 kWh/day was presented in this paper for different continents of the world. The unit cost of electricity generated from the PV system was determined based on their life cycle cost analysis. The capital cost and unit cost of electricity for the SAPV systems were evaluated as $9,198/kWp and $0.6/kWh respectively for India. The total CO2 emission mitigated by the PV power system in its lifespan was estimated at 63 tons which correspond to the carbon credits of $2,048.

[1]  R. Kannan,et al.  Life cycle assessment study of solar PV systems: An example of a 2.7 kWp distributed solar PV system in Singapore , 2006 .

[2]  M. A. Bader,et al.  Cost of solar energy generated using PV panels , 2007 .

[3]  J. Benemann,et al.  Building-integrated PV modules , 2001 .

[4]  X. Vallvé,et al.  Design and operation of a 50 kWp PV rural electrification project for remote sites in Spain , 1997 .

[5]  M. Benghanem,et al.  Performance of stand-alone photovoltaic systems using measured meteorological data for Algiers , 1998 .

[6]  Evert Nieuwlaar,et al.  Energy viability of photovoltaic systems , 2000 .

[7]  M. Watt,et al.  Life‐cycle air emissions from PV power systems , 1998 .

[8]  M. Slesser,et al.  Solar energy breeders , 1976, Nature.

[9]  Jean-Baptiste Lesourd,et al.  Solar photovoltaic systems: the economics of a renewable energy resource , 2001, Environ. Model. Softw..

[10]  M. Ali Asgar,et al.  Sizing of a stand-alone photovoltaic power system at Dhaka , 2003 .

[11]  S. C. Mullick,et al.  Photovoltaic projects for decentralized power supply in India: A financial evaluation , 2006 .

[12]  Arvind Chel,et al.  Energy conservation in honey storage building using Trombe wall , 2008 .

[13]  Somchai Chokmaviroj,et al.  Performance of a 500kWP grid connected photovoltaic system at Mae Hong Son Province, Thailand , 2006 .

[14]  P. P. Groumpos,et al.  An optimum load management strategy for stand-alone photovoltaic power systems , 1991 .

[15]  Arvind Tiwari,et al.  Energy and exergy efficiencies of a hybrid photovoltaic–thermal (PV/T) air collector , 2007 .

[16]  Y. Tripanagnostopoulos,et al.  Hybrid photovoltaic/thermal solar systems , 2002 .

[17]  Kazuhiko Kato,et al.  Energy pay‐back time and life‐cycle CO2 emission of residential PV power system with silicon PV module , 1998 .

[18]  Riccardo Battisti,et al.  Evaluation of technical improvements of photovoltaic systems through life cycle assessment methodology , 2005 .

[19]  J. M. Gordon,et al.  Optimal sizing of stand-alone photovoltaic solar power systems , 1987 .

[20]  Andres Barrado,et al.  Evaluation of a new maximum power point tracker (MPPT) applied to the photovoltaic stand-alone systems , 2005 .

[21]  New Mexico. for Sandia National Laboratories , 2009 .

[22]  G. N. Tiwari,et al.  Performance evaluation and life cycle cost analysis of earth to air heat exchanger integrated with adobe building for New Delhi composite climate , 2009 .

[23]  J. J. Bloem,et al.  Evaluation of a PV-integrated building application in a well-controlled outdoor test environment , 2008 .