A Selective Harmonic Optimization Method for STATCOM in Steady State Based on the Sliding DFT

The low-order harmonic components in the output current of a three-phase three-wire Static Synchronous Compensator (STATCOM) with an LCL filter are inevitable due to the dead time of the switching devices and the tracking speed of the PI controllers when using the inverter-side inductance current as the control object. In order to suppress the selective harmonic components in the steady-state output current, a control method for STATCOM based on the sliding DFT harmonic detection, closed-loop control by the inverter-side inductance current and feed-forward compensation by the selective harmonic current of the grid-side inductance is proposed. The simulation results in Mat lab demonstrate the effectiveness of the proposed selective harmonic optimization method.

[1]  Yan Hongyan,et al.  A control method for SVPWM-based STATCOM using active-reactive current decouple under dq coordinate system , 2012, 2012 International Conference and Exposition on Electrical and Power Engineering.

[2]  Ping Wei,et al.  Harmonic Suppression and Reactive Power Compensation of Shunt Active Power Filter , 2009, 2009 Third International Symposium on Intelligent Information Technology Application.

[3]  Xu Jia-zhu,et al.  LCL output filter design and the influence to the D-STATCOM compensation characteristic , 2011, 2011 International Conference on Electronics, Communications and Control (ICECC).

[4]  Anwar Shahzad Siddiqui,et al.  Enhancing the Power System Loadability Using STATCOM Device , 2015 .

[5]  K.P. Sozanski Sliding DFT control algorithm for three-phase active power filter , 2006, Twenty-First Annual IEEE Applied Power Electronics Conference and Exposition, 2006. APEC '06..

[6]  Qing Lu,et al.  Study on SVG for reactive power compensation and harmonic suppression based on active current separation , 2011, 2011 Chinese Control and Decision Conference (CCDC).

[7]  Xue-song Zhou,et al.  STATCOM control research and analysis , 2010, 2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering.

[8]  Yuan-Yih Hsu,et al.  A Minimal Harmonic Controller for a STATCOM , 2008, IEEE Transactions on Industrial Electronics.

[9]  Steven W. Smith,et al.  The Scientist and Engineer's Guide to Digital Signal Processing , 1997 .

[10]  Liu Jinjun Analysis and Specification of DC Side Voltage in Static Var Generator Regarding Compensation Characteristics , 2010 .

[11]  Patricio G. Donato,et al.  Harmonics Measurement With a Modulated Sliding Discrete Fourier Transform Algorithm , 2014, IEEE Transactions on Instrumentation and Measurement.

[12]  L. Ben-Brahim,et al.  The analysis and compensation of dead-time effects in three phase PWM inverters , 1998, IECON '98. Proceedings of the 24th Annual Conference of the IEEE Industrial Electronics Society (Cat. No.98CH36200).

[13]  Li Gang,et al.  Comparison of Direct and Indirect Current Control Strategy for DSTATCOM , 2006, 2006 International Conference on Power System Technology.

[14]  M. Venkatesh,et al.  Mitigation of Voltage Fluctuations in Power System Using STATCOM , 2014 .